Bernd Gundelsweiler

Prof. Bernd Gundelsweiler

University of Stuttgart
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
MRMarkus Raab
Markus Raab
MHMarco Hutter
Marco Hutter
AKArif Kazi
Arif Kazi
WSWolfgang Schinkoethe
Wolfgang Schinkoethe
BGBernd Gundelsweiler
Bernd Gundelsweiler
This paper presents a magnetically levitated linear drive for precision engineering with integrated active gravity compensation. The gravity compensation combines permanent magnets with novel hybrid shape memory actuators. The magnetically levitated system uses a homopolar linear drive as well as nine reluctance actuators to levitate a passive armature with no mechanical connection between stator and armature. The mechanical design is based on geometrically decoupled horizontal and vertical guidance axes. A decoupled Cartesian control scheme is developed, which compensates for actuator and system non-linearities in order to achieve high bandwidths. The active gravity compensation adjusts the air gap between permanent magnets and armature to the required gravity com-pensation force. This helps to keep dissipated power and temperature increases in the magnetically levitated drive low (and thus system precision high). To avoid generation of particles in clean room applications, the actuators positioning the permanent magnets are solely based on solid state effects: Thermal shape memory alloys (SMA) actively generate motion, while passive magnetic shape memory (MSM) alloy elements realize a multi-stable behavior based on their internal twinning force. The resulting actuator is compact, energy efficient and abrasion-free. The implementation of the gravity compensation in the levitated linear drive is verified and the functionality of the system is demonstrated in experiments.

3 March 2023 in Polymers
Verified
Journal Article
Open access
PDF file
MSMaximilian Schönherr
Maximilian Schönherr
HRHolger Ruehl
Holger Ruehl
TGThomas Günther
Thomas Günther
AZAndre Zimmermann
Andre Zimmermann
BGBernd Gundelsweiler
Bernd Gundelsweiler
The demolding of plastic parts remains a challenging aspect of injection molding. Despite various experimental studies and known solutions to reduce demolding forces, there is still not a complete understanding of the effects that occur. For this reason, laboratory devices and in-process measurement injection molding tools have been developed to measure demolding forces. However, these tools are mostly used to measure either frictional forces or demolding forces for a specific part geometry. Tools that can be used to measure the adhesion components are still the exception. In this study, a novel injection molding tool based on the principle of measuring adhesion-induced tensile forces is presented. With this tool, the measurement of the demolding force is separated from the actual ejection step of the molded part. The functionality of the tool was verified by molding PET specimens at different mold temperatures, mold insert conditions and geometries. It was demonstrated that once a stable thermal state of the molding tool was achieved, the demolding force could be accurately measured with a comparatively low force variance. A built-in camera was found to be an efficient tool for monitoring the contact surface between the specimen and the mold insert. By comparing the adhesion forces of PET molded on polished uncoated, diamond-like carbon and chromium nitride (CrN) coated mold inserts, it was found that a CrN coating reduced the demolding force by 98.5% and could therefore be an efficient solution to significantly improve demolding by reducing adhesive bond strength under tensile loading.

8 May 2025 in International Journal of Hydrogen Energy
Verified
Journal Article
Open access
MFMilan Fitzlaff
Milan Fitzlaff
LSLukas Schmidt
Lukas Schmidt
PSPaul Stannek
Paul Stannek
BGBernd Gundelsweiler
Bernd Gundelsweiler
SPSusanne Palecki
Susanne Palecki
MGMarco Grundler
Marco Grundler

15 August 2023 in Actuators
Verified
Journal Article
Open access
PDF file
MMManuel Mauch
Manuel Mauch
MHMarco Hutter
Marco Hutter
BGBernd Gundelsweiler
Bernd Gundelsweiler
The mobility of today and tomorrow is characterized by technological change and new challenges in drive concepts such as electric or hydrogen vehicles. Abolishing conventional combustion engines creates even more need for switching or valve technology in mobility systems. For switching and controlling purposes, solenoids are used in large numbers and in a wide variety of applications, thus making a significant contribution to the overall success of the energy transition, and not only in the automotive sector. Despite their long existence, continued research is being carried out on solenoids involving new materials and actuator concepts. Great interest is focused on providing an adjustable force–displacement characteristic while simultaneously reducing the noise during switching. At IKFF, research is being conducted on hybrid electromagnets in the border area of switching and holding solenoids. This paper aims to present the major advantages of this hybrid drive concept based on an electromagnetic FEA simulation study of two drive concepts and specially developed and characterized prototypes with magnetic shape memory (MSM) alloys. The concepts differ in the spatial orientation of the MSM sticks to generate an active stroke of the plunger, which contributes to a beneficial force–displacement characteristic and lower power consumption while minimizing switching noise.

6 August 2021 in Actuators
Verified
Journal Article
Open access
PDF file
FSFrank Schiele
Frank Schiele
BGBernd Gundelsweiler
Bernd Gundelsweiler
In this study, a planar ultrasonic motor platform is presented that uses three half-side excited piezoelectric hemispherical shell resonators. To understand the working principle and the harmonic vibration behavior of the piezoelectric resonator, the trajectory of the friction contact was measured in free-oscillating mode at varying excitation frequencies and voltages. The driving performance of the platform was characterized with transport loads up to 5 kg that also serve as an influencing downforce for the friction motor. The working range for various transport loads and electrical voltages up to 30 V is presented. Undesirable noise and parasitic oscillations occur above the detected excitation voltage ranges, depending on the downforce. Therefore, minimum and maximum values of the excitation voltage are reported, in which the propulsion force and the speed of the planar motor can be adjusted, and noiseless motion applies. The multidimensional driving capacity of the platform is demonstrated in two orthogonal axes and one rotary axis in open-loop driving mode, by measuring forces and velocities to confirm its suitability as a planar motor concept. The maximum measured propulsion force of the motor was 7 N with a transport load of 5 kg, and its maximum measured velocity was 77 mm/s with a transport load of 3 kg.

5 February 2025 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
WZWei Zhang
Wei Zhang
BGBernd Gundelsweiler
Bernd Gundelsweiler
Sven UrschelSven Urschel
Sven Urschel
Peristaltic pumps are uniquely suited for transporting sensitive and critical fluids, but conventional designs using rollers have limitations, including mechanical abrasion of components and high wall shear stress, which can damage cell-loaded fluids such as blood. With the growing need for alternatives in fields like microfluidics, bioengineering, and medicine, we propose a magnetic peristaltic pump that eliminates rollers, reducing abrasions, and mechanical stress. This pump is maintenance-free, operates silently due to magnetic actuation, and achieves a maximum flow rate of 130 mL/min, approximately 25% to 66% of that of commercial roller pumps with similar dimensions. To evaluate the pump's performance, we conducted both simulations and experimental measurements, achieving good agreement. A multiphysics model was developed and validated to simulate the system's dynamic behavior, including transient flow rate, pressure, wall shear stress, and Reynolds number. The simulation results show evenly distributed shear stress with peak values below 25 Pa during blood transport, representing an approximately 50% reduction in peak and time-integrated shear stress compared to roller pumps. In the pump experiments, a maximum flow rate of 130 mL/min, a peak back pressure of 4 kPa, and a maximum suction height of 35 cm were achieved.