Jiale Guo

Mr. Jiale Guo


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
JGJiale Guo
Jiale Guo
RHRongsheng Han
Rongsheng Han
ZYZibo Yang
Zibo Yang
GAGuoqing An
Guoqing An
RLRui Li
Rui Li
LZLong Zhang
Long Zhang
The frequency characteristics of the switching-mode power supply (SMPS) control loop under all operating conditions are crucial for performance evaluation and defect detection. Traditional methods, relyingon experiments under preset conditions, struggle to achieve comprehensive evaluation. This study proposes a frequency characteristic fitting method for all operating conditions based on FT-WOA-MLP. A discrete-point dataset covering all conditions of an LLC SMPS was obtained using the small-signal perturbation method, including input voltage, output current, injection frequency, and corresponding amplitude- and phase-frequency characteristics. The multilayer perceptron (MLP) model was trained on the training set covering all operating conditions, with the whale optimization algorithm (WOA) used to optimize the learning rate, and fine tuning (FT) applied to further enhance accuracy. Independent test set validation showed that, for amplitude-frequency characteristics, the mean absolute error (MAE) was 2.0995, the mean absolute percentage error (MAPE) was 0.0974, the root mean square error (RMSE) was 4.0474, and the coefficient of determination (R2) reached 0.92; for phase-frequency characteristics, the MAE was 3.502, the MAPE was 0.0956, the RMSE was 10.5192, and the R2 reached 0.94. The method accurately fits frequency characteristics under all conditions, supporting defect identification and performance optimization.

Verified
Journal Article
Open access
PDF file
ZYZibo Yang
Zibo Yang
JGJiale Guo
Jiale Guo
RLRui Li
Rui Li
GAGuoqing An
Guoqing An
KZKai Zhang
Kai Zhang
LZLong Zhang
Long Zhang
To address the limited defect-detection capability of existing performance testing methods for switching power supplies under varying operating conditions, this paper proposes a defect identification approach based on an enhanced Dung Beetle Optimizer. The algorithm integrates multi-strategy improvements—including piecewise chaotic mapping, Lévy flight perturbation, hybrid sine–cosine updating, and an alert sparrow mechanism—to refine the initial population generation, position update rules, and late-stage exploration. These enhancements strengthen its spatial search ability and computational performance. The experimental results show that the method accurately identifies the predefined defect intervals with a precision of 94.79%, covering 91.3% of the operating conditions. Comparisons with existing mainstream methods confirm the superior performance, effectiveness, and feasibility of the proposed method.