Guizao Huang

Prof. Guizao Huang

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Cold Regions Science and Technology
Verified
Journal Article
Closed access
GHGuizao Huang
Guizao Huang
BYBo Yan
Bo Yan
NWNan Wen
Nan Wen
CWChuan Wu
Chuan Wu
QLQing Li
Qing Li

1 May 2020 in Cold Regions Science and Technology
Verified
Journal Article
Closed access
ZMZheyue Mou
Zheyue Mou
BYBo Yan
Bo Yan
XLXiang Lin
Xiang Lin
GHGuizao Huang
Guizao Huang
XLXin Lv
Xin Lv

25 May 2022 in High Voltage
Verified
Journal Article
Open access
GHGuizao Huang
Guizao Huang
BYBo Yan
Bo Yan
Yujun GuoYujun Guo
Yujun Guo
BZBo Zhang
Bo Zhang
GWGuangning Wu
Guangning Wu
The dynamic response characteristics, including maximum jump height and unbalanced tension, of isolated‐span transmission lines after ice‐shedding are investigated by means of experiments. A reduced‐scale modelling method for ice‐shedding from conductor lines is presented and verified with numerical simulations and full‐scale test results in the literature. A parameter study on dynamic responses of isolated‐span conductors under three ice‐shedding scenarios, including whole span ice‐shedding, partial ice‐shedding and unzipping ice‐shedding, is carried out by means of reduced‐scale modelling tests. The effects of these parameters on the maximum jump height at typical positions and unbalanced tension in the tension tower are obtained. It is observed that the partial ice‐shedding scenario may be the worst situation for electrical insulation clearance rather than the whole span ice‐shedding scenario. Moreover, the position of maximum jump height along the span of isolated‐span transmission lines after ice‐shedding could be at around 2/5 of span length, which is different from the conventional opinion that the position is at the midpoint. The results may provide a foundation for the defining of the insulation clearance for an isolated‐span transmission line and the structure design of tension tower arms in an iced zone.

1 June 2022 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
CLChunmao Li
Chunmao Li
QDQing Du
Qing Du
Yujun GuoYujun Guo
Yujun Guo
YLYijie Liu
Yijie Liu
FYFeng Yang
Feng Yang
GWGuangning Wu
Guangning Wu
The risks of power supply in power systems attributed to stray currents caused by denser metro lines are increasing in modern megacities. Factors such as multi-layered soil and multiple metro operating lines (MOLs) make it more difficult to analyze dc coupling between the metro and power system. This article proposes a model for dc coupling of the metro and power system considering the two systems’ spatial information, the actual multi-layered soil, and the non-linear ionization of soil caused by stray currents. This article presents a dc coupling model suitable for studying multiple metro lines and large-scale power systems in modern megacities, which has an average relative error of 6.3% compared with experimental results. The neutral current of the transformer in a substation is up to 43 A (normal operation requires it to be less than 6 A in amplitude) under the influence of multiple MOL. The non-linear ionization of the soil near the power substations’ grounding network will decrease the soil resistance, this also results in greater dc currents intruding into power substations.

8 June 2023 in Journal of Cleaner Production
Verified
Journal Article
Closed access
GHGuizao Huang
Guizao Huang
GWGuangning Wu
Guangning Wu
YGYujun Guo
Yujun Guo
MLMing Liang
Ming Liang
JLJun Li
Jun Li
GGGuoqiang Gao
Guoqiang Gao

15 May 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
ZLZheng Li
Zheng Li
GWGuangning Wu
Guangning Wu
GHGuizao Huang
Guizao Huang
Yujun GuoYujun Guo
Yujun Guo
HZHongyu Zhu
Hongyu Zhu
The pantograph-catenary system, serving as the ’throat’ for the energy supply of high-speed railways, inevitably experience current degradation caused by ice accumulation on the catenary when high-speed trains pass through areas with high relative humidity, low temperature, and high wind speeds. To explore the impact of the complex service environment on the growth process of catenary icing, this paper, based on the study of the mechanism of catenary icing, proposes an ice prediction method for catenary icing oriented to numerical model and deep learning. Firstly, based on the calculation of key parameters such as capture rate, freezing coefficient, and collision coefficient, a numerical model for catenary icing under time-varying meteorological conditions is developed. Secondly, study the impact of four factors, including wind speed, temperature, liquid water content (LWC), and median volume diameter (MVD), on the evolution of catenary icing. Finally, by integrating the convolutional neural network-long short-term memory (CNN-LSTM), a prediction model for catenary icing is established. The study addressed challenges such as unclear mechanisms of catenary icing, difficulties in detecting icing states, and insufficient sample data. It laid a theoretical foundation for icing forecasting and warning, selection of de-icing strategies, and research on the dancing of catenary icing.