基哲 黃

Dr. 基哲 黃

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Measurement
Verified
Journal Article
Closed access
基黃基哲 黃
基哲 黃
HSHao-Yi Syu
Hao-Yi Syu
ZCZhe-Lin Cai
Zhe-Lin Cai
ASAaron Raymond See
Aaron Raymond See

30 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CHChun-Ju Hou
Chun-Ju Hou
YCYen-Ting Chen
Yen-Ting Chen
MCMycel Alagar Capilayan
Mycel Alagar Capilayan
YLYu-Sian Lin
Yu-Sian Lin
MHMin-Wei Huang
Min-Wei Huang
基黃基哲 黃
基哲 黃
As the proportion of elderly people continues to grow, so does the concern about age-related cognitive decline. Serious games have been developed for cognitive training or treatment, but measuring the activity of the autonomic nervous system (ANS) has not been taken to account. However, cognitive functioning has been known to be heavily influenced by the autonomic nervous system (ANS), and ANS activity can be quantified using heart rate variability (HRV). This paper aims to analyze the physiological response in normal elderly people as they play two types of serious games using HRV features from electrocardiography (ECG). A wearable device designed in-house was used to measure ECG, and the data from this device was pre-processed using digital signal processing techniques. Ten HRV features were extracted, including time-domain, nonlinear, and frequency-domain features. The experiment proceeds as follows: rest for three minutes, play a cognitive aptitude game, rest for another three minutes, followed by two reaction time games. Data from thirty older adults (age: 65.9 ± 7.34; male: 15, female: 15) were analyzed. The statistical results show that there was a significant difference in the HRV between the two types of games. From this, it can be concluded that the type of game has a significant effect on the ANS response. This can be further used in designing games for the elderly, either for training or mood management.

20 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CHChun-Ju Hou
Chun-Ju Hou
YCYen-Ting Chen
Yen-Ting Chen
MCMycel A. Capilayan
Mycel A. Capilayan
MHMin-Wei Huang
Min-Wei Huang
基黃基哲 黃
基哲 黃
Cognitive decline is one of the primary concerns in the elderly population. Serious games have been used for different purposes related to elderly care, such as physical therapy, cognitive training and mood management. There has been scientific evidence regarding the relationship between cognition and the autonomic nervous system (ANS) through heart rate variability (HRV). This paper explores the changes in the ANS among elderly people of normal and impaired cognition through measured HRV. Forty-eight subjects were classified into two groups: normal cognition (NC) (n = 24) and mild cognitive impairment (MCI) (n = 24). The subjects went through the following experiment flow: rest for 3 min (Rest 1), play a cognitive aptitude game (Game 1), rest for another 3 min (Rest 2), then play two reaction-time games (Game 2&3). Ten HRV features were extracted from measured electrocardiography (ECG) signals. Based on statistical analysis, there was no significant difference on the HRV between the two groups, but the experiment sessions do have a significant effect. There was no significant interaction between sessions and cognitive status. This implies that the HRV between the two groups have no significant difference, and they will experience similar changes in their HRV regardless of their cognitive status. Based on the game performance, there was a significant difference between the two groups of elderly people. Tree-based pipeline optimization tool (TPOT) was used for generating a machine learning pipeline for classification. Classification accuracy of 68.75% was achieved using HRV features, but higher accuracies of 83.33% and 81.20% were achieved using game performance or both HRV and game performance features, respectively. These results show that HRV has the potential to be used for detection of mild cognition impairment, but game performance can yield better accuracy. Thus, serious games have the potential to be used for assessing cognitive decline among the elderly.

8 July 2020 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
基黃基哲 黃
基哲 黃
ZCZhe-Lin Cai
Zhe-Lin Cai
The purpose of this study is to utilize flexible curved noncontact active electrodes to develop a nonperception, long-term, and wireless heart rate monitoring system. This study also verified the functions and capabilities of the system and provided information on physiological parameters recorded during our tests. Our system was used in tandem with a commercially standard measurement system; both systems were used to measure ECG signals on 10 healthy subjects under the simulated home and office scenarios. We verified the R-peak measurement accuracy of our system and used T-tests to analyze the data collected by both systems; our system reached an average sensitivity value of 0.983 and an average positive predictive value of 0.991 over several different scenarios where R-peak measurements were also highly accurate. The R-R time intervals of our system were highly consistent with the standard system. The correlation coefficient calculated reached almost one, and the differences between the two systems mostly fell within the ±10 ms range. Further study of the HRV time-domain parameters under four different scenarios showed no significant differences in most HRV parameters compared to the measurements by the standard system. We also used our system to record long-term heart rate signals.

2 July 2017 in ECTI Transactions on Computer and Information Technology (ECTI-CIT)
Verified
Journal Article
Open access
PDF file
基黃基哲 黃
基哲 黃
YHYang-Min Huang
Yang-Min Huang
ASAaron Raymond See
Aaron Raymond See
In this study, a simple bioimpedance plethysmography method was employed to measure the pulse wave velocity (PWV) from the radial artery in the wrist to the middle finger of a patient. Subsequently, electrocardiography was combined with a bioimpedance method to calculate the PWV from ECG and pulse waves to the middle finger. Experiments were conducted by employing cuffs that temporarily block blood flow to produce observable changes in the PWV. Statistical results indicated that temporary blockage of blood flow did not influence the PWV of typical healthy people. Moreover, multiple regression analysis was used to establish an equation for estimating two types of PWV and their relevance with other physiological parameters. Multiple regression analysis indicated that the abdomen circle and height are independent predictors of the PWV from the radial artery in the wrist to the middle finger (wfPWV) (r = 0.893). Systolic blood pressure (SBP) and diastolic blood pressure (DBP) are independent predictors of the PWV from the EGC T wave to the middle finger (tfPWV) (r = 0.898). Correlation analysis showed the wfPWV is significantly associated with tfPWV (r = 0.770, p < 0.01).

12 July 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Angelino Angeles PimentelAngelino Angeles Pimentel
Angelino Angeles Pimentel
基黃基哲 黃
基哲 黃
ASAaron Raymond See
Aaron Raymond See
Traditional cuff-based blood pressure (BP) monitoring methods provide only intermittent readings, while invasive alternatives pose clinical risks. Recent studies have demonstrated feasibility of estimating continuous non-invasive cuff-less BP using photoplethysmogram (PPG) signals alone. However, existing approaches rely on complex manual feature engineering and/or multiple model architectures, resulting in inefficient epoch training numbers and limited performance. This research proposes cBP-Tnet, an efficient single-channel and model multi-task Transformer network designed for PPG signal automatic feature extraction. cBP-Tnet employed specialized hyperparameters—integrating adaptive Kalman filtering, outlier elimination, signal synchronization, and data augmentation—leveraging multi-head self-attention and multi-task learning strategies to identify subtle and shared waveform patterns associated with systolic blood pressure (SBP) and diastolic blood pressure (DBP). We used the MIMIC-II public dataset (500 patients with 202,956 samples) for experimentation. Results showed mean absolute errors of 4.32 mmHg for SBP and 2.18 mmHg for DBP. For the first time, both SBP and DBP meet the Association for the Advancement of Medical Instrumentation’s international standard (85 subjects). Furthermore, the network efficiently reduces the epoch training number by 13.67% when compared to other deep learning methods. Thus, this establishes cBP-Tnet’s potential for integration into wearable and home-based healthcare devices with continuous non-invasive cuff-less blood pressure monitoring.