Hanane AIT LAHOUSSINE OUALI

Dr. Hanane AIT LAHOUSSINE OUALI

Mohamed I University, Oujda, Morocco
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
HOHanane AIT LAHOUSSINE OUALI
Hanane AIT LAHOUSSINE OUALI
Ahmed Alami MerrouniAhmed Alami Merrouni
Ahmed Alami Merrouni
SCShahariar Chowdhury
Shahariar Chowdhury
KTKuaanan Techato
Kuaanan Techato
SCSITTIPORN CHANNUMSIN
SITTIPORN CHANNUMSIN
NUNasim Ullah
Nasim Ullah
Morocco is a country with a lack of fossil fuel resources and an increasing demand for energy. This inspired the country to increase the use of renewable energy in the energy mix. The objective of this study was to conduct an optimization and techno-economic appraisal of a concentrated solar power plant (CSP) using different scenarios that took Ouarzazate city in the south of Morocco as a case study. To achieve this, several parameters were assessed, including the impacts of solar collector assemblies (SCAs), receiver types, heat transfer fluids, cooling systems, solar multiples, and thermal storage hours, with regard to the profitability of the CSP plant. Then, performance and sensitivity analyses were conducted to select the best integration scenarios based on different economic indicators, including levelized cost of electricity (LCOE) and net present value (NPV). The findings revealed that the use of the Luz LS-3 as the collector/SCA, Solel UVAC 3 as receiver, and Dowtherm Q as heat transfer fluid exhibited the highest performance in terms of the annual energy production yield and capacity factor, as well as the lowest real and nominal LCOEs with a wet cooled condenser. Furthermore, the LCOE is extremely sensitive to changes in the number of hours of storage and the solar multiple, and the optimal real and nominal LCOEs are determined by a highly specific combination of the solar multiple and the number of hours of storage. As a consequence, the maximum and minimum net electricity outputs for the best configuration of the Parabolic Trough Collector (PTC) plant were 24.6 GWh and 7.4 GWh in May and December, respectively. Likewise, the capacity factor and the gross-to-net conversion factor for the optimized plant were found to be 47.9%, and 93.5%, respectively. Concerning the economic study, the expected energy cost was 0.1303 USD per kWh and the NPV value for Ouarzazate city was positive (more than USD 20 million), which indicates that the studied PTC plant was estimated to be financially and economically feasible. The results of this analysis are highly significant and may persuade decision makers, financiers, and solar energy industry players to increase their investments in the Kingdom of Morocco.

1 January 2017 in Applied Solar Energy
Verified
Journal Article
Closed access
PDF file
HOHanane AIT LAHOUSSINE OUALI
Hanane AIT LAHOUSSINE OUALI
RGR. Guechchati
R. Guechchati
MMM. A. Moussaoui
M. A. Moussaoui
AMAhmed Mezrhab
Ahmed Mezrhab
A numerical simulation of Concentrating Solar Power (CSP) plant based on an Organic Rankine Cycle (ORC) power generation unit integrated with parabolic trough collectors is carried out. For the study we refer to the Solar Electric Generating System VI (SEGS VI), installed in the Mojave desert-California (USA), whose solar field which is constituted by LS2 parabolic trough collectors and we consider the same plant implementation in the region of Oujda city (Morocco). To predict the energy performance, the simulations are carried out using TRNSYS 16 simulation program known for its modularity and flexibility and the external library known as the Solar Thermal Electric Components (STEC) library. The meteorological parameters including Direct Normal Irradiation (DNI), ambient temperature and other weather conditions are taken from meteorological year database provided by a high precision MHP station located in Mohamed Premier University. The obtained results show that the region of East offers great potential in general for implementing this type of plant. In fact, the value of 30 MWe is reached during the strongest sunshine day and the operating time can go from 7 AM until 19 PM for a summer day.

1 May 2016
Verified
Conference Paper
Closed access
Ahmed Alami MerrouniAhmed Alami Merrouni
Ahmed Alami Merrouni
HOHanane AIT LAHOUSSINE OUALI
Hanane AIT LAHOUSSINE OUALI
MMMohammed Amine Moussaoui
Mohammed Amine Moussaoui
AMAhmed Mezrhab
Ahmed Mezrhab
The present work contains a numerical simulation of a 1MWe parabolic trough solar collector using 6 various Heat Transfer Fluids (HTF) under the weather conditions of Oujda (Morocco). Our objective is to study the performances of different HTFs and make a comparison between them in order to find out the most suitable HTF to be used for small scale solar plants. The main results of the simulations show that the VP1 is the best one to be used in this conditions, since it's the one that provide the highest thermal and electrical production that reach 650MWth and 200MWe in June respectively. However, the Molten Salts (Hitec and Solar Salt) are the disproportionate ones because the lowest thermal and electrical production.

1 March 2015
Verified
Conference Paper
Closed access
HOHanane AIT LAHOUSSINE OUALI
Hanane AIT LAHOUSSINE OUALI
Ahmed Alami MerrouniAhmed Alami Merrouni
Ahmed Alami Merrouni
MMMohammed Amine Moussaoui
Mohammed Amine Moussaoui
AMAhmed Mezrhab
Ahmed Mezrhab
This paper presents the simulation results of a 50 MWe solar thermal tower plant under the climate of Oujda, a city located at North-east of Morocco. For this purpose, one year of meteorological data with one minute step has been collected via a high precision meteorological station installed at the University of Oujda. Afterward, a meteo-file of one hour step has been created and injected to Greenius simulation software, in order to calculate the annual yield electricity production of a 50 MWe solar tower with an open air volumetric receiver and one tank storage system. For an annual direct normal irradiation (DNI) of 1989.9 kWh/m2, the tower produces a thermal energy of 387 768 MWhth and an annual electricity of 144 909 MWhel. The mean efficiency of the tower system under the climate of Oujda is of 13.6%, which can be considered as high and cost effective.

1 July 2020 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
HOHanane AIT LAHOUSSINE OUALI
Hanane AIT LAHOUSSINE OUALI
MMMohammed Amine Moussaoui
Mohammed Amine Moussaoui
AMAhmed Mezrhab
Ahmed Mezrhab
Hassane NajiHassane Naji
Hassane Naji
This study deals with a numerical investigation to assess and compare the thermal and economic performance of two solar tower power systems. It concerns the Molten Salt (MS) and Direct Steam Generation (DSG) technologies used as heat carrier and storage. For this purpose, a 50 MWe solar tower plant without thermal energy storage under the climatic conditions of the eastern Moroccan region is simulated with the System Advisor Model (SAM) software. The meteorological data has been collected via a high precision meteorological station located in Oujda city(34 degrees 40'53 '' N 1 degrees 54'30.9 '' W). The results are presented in terms of monthly energy production, annual energy output, and Levelized Electricity Cost (LEC). From these findings, it can be concluded that, for an amount annual Direct Normal Irradiance (DNI) of 1989.9 kWh/m(2)/yr, the molten salt plant has the highest annual energy production than the DSG (86.3 GWh for MS against 83.3 GWh for DSG) and the LEC of the Molten salt plant is 12.5 % lower than the DSG plant. (c) 2020. CBIORE-IJRED. All rights reserved

1 July 2019
Verified
Conference Paper
Closed access
LBLatifa EL Boujdaini
Latifa EL Boujdaini
HOHanane AIT LAHOUSSINE OUALI
Hanane AIT LAHOUSSINE OUALI
AMAhmed Mezrhab
Ahmed Mezrhab
MMMohammed Amine Moussaoui
Mohammed Amine Moussaoui
In this paper, we established the mathematical model of a solar parabolic trough plant with a molten salt indirect storage, and then we simulated the model using Matlab software. The reference plant ‘‘Andasol-1" with 50MWe were used to validate the simulated results. After that, we studied the storage size impact on the levelized cost of electricity (LCOE) by developing optimization methods based on hours of storage (TES) and solar multiple (SM). A comparison is achieved for different sites due to the developed option in our code, which gives for any known DNI location the LCOE. We found that the lowest LCOE belongs to Ouarzazate in comparison to Andasol-1 (Spain), Bechar (Algeria), Titaouine (Tunisia) and Oujda (our study case). For Oujda, the different simulated results are approximately the same as the case of Andasol-1 (LCOE is about 0.25 €/KWh with a solar multiple equals to 2).