Venting range hoods can control indoor air pollutants emitted during residential cooktop and oven cooking. To quantify their potential benefits, it is important to know how frequently and under what conditions range hoods are operated during cooking. We analyzed data from 54 single family houses and 17 low-income apartments in California in which cooking activities, range hood use, and fine particulate matter (PM2.5) were monitored for one week per home. Range hoods were used for 36% of cooking events in houses and 28% in apartments. The frequency of hood use increased with cooking frequency across homes. In both houses and apartments, the likelihood of hood use during a cooking event increased with the duration of cooktop burner use, but not with the duration of oven use. Actual hood use rates were higher in the homes of participants who self-reported more frequent use in a pre-study survey, but actual use was far lower than self-reported frequency. Residents in single family houses used range hoods more often when cooking caused a discernible increase in PM2.5. In apartments, residents used their range hood more often only when high concentrations of PM2.5 were generated during cooking.
Recent experiments have demonstrated that outdoor ozone reacts with materials inside residential building enclosures, potentially reducing indoor exposures to ozone or altering ozone reaction byproducts. However, test methods to measure ozone penetration factors in residences (P) remain limited. We developed a method to measure ozone penetration factors in residences under infiltration conditions and applied it in an unoccupied apartment unit. Twenty-four repeated measurements were made, and results were explored to (i) evaluate the accuracy and repeatability of the new procedure using multiple solution methods, (ii) compare results from ‘interference-free’ and conventional UV absorbance ozone monitors, and (iii) compare results against those from a previously published test method requiring artificial depressurization. The mean (±s.d.) estimate of P was 0.54 ± 0.10 across a wide range of conditions using the new method with an interference-free monitor; the conventional monitor was unable to yield meaningful results due to relatively high limits of detection. Estimates of P were not clearly influenced by any indoor or outdoor environmental conditions or changes in indoor decay rate constants. This work represents the first known measurements of ozone penetration factors in a residential building operating under natural infiltration conditions and provides a new method for widespread application in buildings.