Ronny Hartanto

Prof. Dr. Ronny Hartanto


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
ASAndy Stamm
Andy Stamm
RHRonny Hartanto
Ronny Hartanto
Athlete monitoring is a major field of interest for professional and recreational runners as well as for coaches to improve performance and reduce injury risk. The development of inertial sensors in recent years offers the opportunity to improve the number of monitored training sessions significantly. This research used a self-developed inertial sensor in conjunction with a motion tracking system and four smart bands to record the runner’s movement and extract parameters such as step numbers and frequencies. The data recorded were calibrated before it was high-pass filtered to remove gravity components from the signal. A peak detection algorithm was developed to find the number of steps, which have been further used to compare the different systems (IMU, motion capture, smart bands) and find their agreement. The results showed a very strong correlation between the IMU and the motion tracking system of r2 = 0.998, and an r2 = 0.996 between the IMU and one smart band.

14 September 2018
Verified
Conference Paper
Closed access
PDF file
FRFlorian Roesner
Florian Roesner
CCClein Alexander Sarmiento Castrillión
Clein Alexander Sarmiento Castrillión
RHRonny Hartanto
Ronny Hartanto
ASAlexander Struck
Alexander Struck

8 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ASAndy Stamm
Andy Stamm
RHRonny Hartanto
Ronny Hartanto
NBNoah Becker
Noah Becker
This research utilizes a self-developed inertial sensor in conjunction with a motion tracking system and four Smart Bands to record a runner’s movements and extract parameters such as step numbers, length, and frequencies at different running speeds. The data obtained were processed to find the number of steps taken. These steps were also recorded by an IMU (inertial measurement unit) and motion tracking system (MoCap—Motion Capturing) and used to compare the different systems and find their agreement at different running speeds. The results show a very strong correlation between the IMU and the motion tracking system with r2 = 0.968 at 6 km/h, r2 = 0.991 at 8 km/h, r2 = 0.991 at 10 km/h, and r2 = 0.996 at 12 km/h. The Xiaomi Mi Band 2 showed an r2 = 0.861 at 6 km/h, r2 = 0.985 at 8 km/h, r2 = 0.977 at 10 km/h, and r2 = 0.987 at 12 km/h and can therefore be considered a good replacement for an IMU.

14 September 2018
Verified
Book Chapter
Closed access
PDF file
YKYu-Jeng Kuo
Yu-Jeng Kuo
AMArindam Mahanta
Arindam Mahanta
AIAnoshan Indreswaran
Anoshan Indreswaran
ASAlexander Struck
Alexander Struck
RHRonny Hartanto
Ronny Hartanto