Hamid Asadi-Ghoozhdi

Dr. Hamid Asadi-Ghoozhdi

University of Tehran, Tehran, Tehrān, Iran
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2022 in Structures
Verified
Journal Article
Closed access
HAHamid Asadi-Ghoozhdi
Hamid Asadi-Ghoozhdi
RAReza Attarnejad
Reza Attarnejad
Amir R. MasoodiAmir R. Masoodi
Amir R. Masoodi
AMArsalan Majlesi
Arsalan Majlesi

11 September 2022 in Buildings
Verified
Journal Article
Open access
PDF file
AMArsalan Majlesi
Arsalan Majlesi
HAHamid Asadi-Ghoozhdi
Hamid Asadi-Ghoozhdi
OBOmid Bamshad
Omid Bamshad
RAReza Attarnejad
Reza Attarnejad
Amir R. MasoodiAmir R. Masoodi
Amir R. Masoodi
MGMehdi Ghassemieh
Mehdi Ghassemieh
Steel plate shear walls usually do not satisfy the strong-column weak-beam design criteria, leading to larger column sections. On the other hand, rigid frame structures are typically constructed in low-rise to mid-rise buildings built in locations prone to strong earthquakes due to their high flexibility and cost-effective solutions. Overcoming these restrictions to the SPSW system, this paper is dedicated to employing a semi-rigid connection that dissipates energy well and reduces the forces applied to the structure. By using a semi-rigid connection in an adjacent span to the SPSW, the actual flexural capacity of the beam end decreases and, subsequently, improves the performance of the structure in terms of the of the strong-column weak-beam criteria. Thereupon, the impact of the semi-rigid connections on steel frames with SPSWs as a sideway resisting system can be assessed by implementing a numerical study. In this paper, a new methodology for modelling semi-rigid joints is used considering five connections with different moment capacities. Moreover, the influence of three different circular diameters on the behavior of the perforated SPSWs was investigated. To fulfil these purposes, nonlinear dynamic analysis was conducted to assess the reliability of 5-, 10-, and 15-story frames resisted with SPSWs and semi-rigid connections subjected to actual ground motion records. A total of 45 frames were modelled and the obtained results were compared with reference benchmarks. The outcomes of the studies show good agreement with design building code requirements. In addition, the reliable performance of the structure under seismic loads is evaluated. According to the results of the parametric study, the presumed allowable drift leads to obtaining the optimum moment capacity of connection for each model and illustrates the applicability of a new structural system consisting of SPSWs and semi-rigid connections simultaneously.


8 June 2020 in International Journal of Civil Engineering
Verified
Journal Article
Closed access
PDF file
HAHamid Asadi-Ghoozhdi
Hamid Asadi-Ghoozhdi
RAReza Attarnejad
Reza Attarnejad

17 July 2018 in Scientia Iranica
Verified
Journal Article
Closed access
PDF file
HAHamid Asadi-Ghoozhdi
Hamid Asadi-Ghoozhdi
MMMasood Mofid
Masood Mofid
Recently, a novel structural system, which is defined as damped outrigger system, has been proposed to control dynamic vibration of tall buildings. This paper examines seismic performance of tall buildings involving multiple outriggers equipped with viscous dampers. In this respect, a dual structural system (braced moment frame) is selected as a bare structure. In addition, the number and position of outriggers are assumed to be variable along the height of structure. Nonlinear response history analysis (RHA) is performed to evaluate the efficiency of damped-outrigger system under eight scaled ground motions. The results are presented based on the average of all ground motions. The mean inter-story drift ratio and maximum base shear force are compared in order to determine the best arrangement of damped outriggers. Conclusively, based on minimizing base shear force, the optimal location of damped outriggers under dynamic excitation is generally the same as that made for conventional outriggers. According to the inter-story drift ratio parameter, it is recommended to place one of the outriggers at the roof level.