Hrvoje Dodig

Dr. Hrvoje Dodig

University of Split
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2014 in Engineering Analysis with Boundary Elements
Verified
Journal Article
Closed access
DPDragan Poljak
Dragan Poljak
DCDamir Cavka
Damir Cavka
Hrvoje DodigHrvoje Dodig
Hrvoje Dodig
CPCristina Peratta
Cristina Peratta
APAndres Peratta
Andres Peratta

25 August 2021 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
ASAnna Susnjara
Anna Susnjara
Hrvoje DodigHrvoje Dodig
Hrvoje Dodig
DPDragan Poljak
Dragan Poljak
MCMario Cvetković
Mario Cvetković
The article deals with stochastic-deterministic thermal dosimetry in lower portion of GHz frequency range for human exposure to radiation from 5G communication systems. Deterministic assessment of a temperature distribution in multilayered head model is based on the finite element solution of Pennes equation while the stochastic analysis uses the stochastic collocation approach. Thermal conductivity and volumetric blood perfusion rate of scalp, skull, and brain tissues are modeled as uniformly distributed random parameters, while values of other thermal input parameters are fixed to their respective average values. The stochastic mean and variance of the heating factor at 3.5 GHz are computed and confidence interval is estimated for some observation points of interest. By using “one-at-a-time” and analysis of variance principles, sensitivity analysis of input parameter set is carried out. Some illustrative numerical results stemming from deterministic and stochastic model, respectively, are presented. When observing the impact of input parameters on heating factor values in the direction of incidence, blood perfusion of scalp is dominant with exception in the interior head parts, where the impact of the brain blood perfusion prevails. For the exposure scenario of interest, the temperature elevation is within the limits given by basic restrictions.

1 December 2014 in Engineering Analysis with Boundary Elements
Verified
Journal Article
Closed access
Hrvoje DodigHrvoje Dodig
Hrvoje Dodig
SLS. Lalléchère
S. Lalléchère
PBP. Bonnet
P. Bonnet
DPD. Poljak
D. Poljak
KDKhalil El Khamlichi Drissi
Khalil El Khamlichi Drissi

14 April 2021 in International Journal for Numerical Methods in Engineering
Verified
Journal Article
Closed access
PDF file
Hrvoje DodigHrvoje Dodig
Hrvoje Dodig
DPDragan Poljak
Dragan Poljak
MCMario Cvetković
Mario Cvetković

1 January 2017 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
MCMario Cvetković
Mario Cvetković
Hrvoje DodigHrvoje Dodig
Hrvoje Dodig
DPDragan Poljak
Dragan Poljak
The paper presents the numerical results for the induced electric field in the various models of the human eye and the head. The comparison between the extracted or the single organ models and the compound organ models placed inside realistic head models obtained from the magnetic resonance imaging scans is presented. The numerical results for several frequencies and polarizations of the incident electromagnetic (EM) plane wave are obtained using the hybrid finite element method/boundary element method (FEM/BEM) formulation and the surface integral equation (SIE) based formulation featuring the use of method of moments, respectively. Although some previous analysis showed the similar distribution of the induced electric field along the pupillary axis obtained in both eye models, this study showed this not to be the case in general. The analysis showed that the compound eye model is much more suitable when taking into account the polarization of the incident EM wave. The numerical results for the brain models showed much better agreement in the maximum values and distributions of the induced surface field between detailed models, while homogeneous brain model showed better agreement with the compound model in the distribution along selected sagittal axis points. The analysis could provide some helpful insights when carrying out the dosimetric analysis of the human eye and the head/brain exposed to high frequency EM radiation.

1 August 2020 in Engineering Analysis with Boundary Elements
Verified
Journal Article
Closed access
AŠAnna Šušnjara
Anna Šušnjara
Hrvoje DodigHrvoje Dodig
Hrvoje Dodig
MCMario Cvetković
Mario Cvetković
DPDragan Poljak
Dragan Poljak