Helmi Hadi

Dr. Helmi Hadi

Universiti Sains Malaysia,, Kota Bharu, Kelantan, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Johari Yap AbdullahJohari Yap Abdullah
Johari Yap Abdullah
Cicero André da Costa MoraesCicero André da Costa Moraes
Cicero André da Costa Moraes
MSMohd Mokhtar Saidin
Mohd Mokhtar Saidin
ZRZainul Ahmad Rajion
Zainul Ahmad Rajion
HHHelmi Hadi
Helmi Hadi
Jafri Malin AbdullahJafri Malin Abdullah
Jafri Malin Abdullah
Forensic facial approximation was applied to a 5000-year-old female skull from a shell midden in Guar Kepah, Malaysia. The skull was scanned using a computed tomography (CT) scanner in the Radiology Department of the Hospital Universiti Sains Malaysia using a Light Speed Plus scanner with a 1 mm section thickness in spiral mode and a 512 × 512 matrix. The resulting images were stored in Digital Imaging and Communications in Medicine (DICOM) format. A three-dimensional (3D) model of the skull was obtained from the CT scan data using Blender’s 3D modelling and animation software. After the skull was reconstructed, it was placed on the Frankfurt plane, and soft tissue thickness markers were placed based on 34 Malay CT scan data of the nose and lips. The technique based on facial approximation by data extracted from facial measurements of living individuals showed greater anatomical coherence when combined with anatomical deformation. The facial approximation in this study will pave the way towards understanding face prediction based on skull structures, soft tissue prediction rules, and soft tissue thickness descriptors.

1 March 2020 in Anatomy & Cell Biology
Verified
Journal Article
Open access
SASiti Hanum Mohd Ali
Siti Hanum Mohd Ali
NONormaliza Omar
Normaliza Omar
MSMohamed Swarhib Shafie
Mohamed Swarhib Shafie
NINik Azuan Nik Ismail
Nik Azuan Nik Ismail
HHHelmi Hadi
Helmi Hadi
FNFaridah Mohd Nor
Faridah Mohd Nor
Ali SH, et al. Anat Cell Biol. 2020 Jan;53:e22. https://doi.org/10.5115/acb.19.135

1 April 2014 in Forensic Science International
Verified
Journal Article
Closed access
HHHelmi Hadi
Helmi Hadi
CWCaroline Wilkinson
Caroline Wilkinson

31 December 2022 in Anatomy & Cell Biology
Verified
Journal Article
Open access
PDF file
KTKui Fei Teo
Kui Fei Teo
MNMurshida Marizan Nor
Murshida Marizan Nor
AMAlizae Marny Fadzlin Syed Mohamed
Alizae Marny Fadzlin Syed Mohamed
HHHelmi Hadi
Helmi Hadi
Kui Fei Teo, Murshida Marizan Nor, Alizae Marny Mohamed, Helmi Mohd Hadi Pritam. Anat Cell Biol 2022;55:433-40. https://doi.org/10.5115/acb.22.081

19 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Johari Yap AbdullahJohari Yap Abdullah
Johari Yap Abdullah
AAAbdul manaf Abdullah
Abdul manaf Abdullah
PLPeh Hueh Low
Peh Hueh Low
AHAdam Husein
Adam Husein
HHHelmi Hadi
Helmi Hadi
ZRZainul Ahmad Rajion
Zainul Ahmad Rajion
Reconstructing a large skull defect is a challenge, as it normally involves the use of sophisticated proprietary image processing and expensive CAD software. As an alternative, open-source software can be used for this purpose. This study aimed to compare the 3D cranial implants reconstructed from computed tomography (CT) images using the open-source MITK software with commercial 3-matic software for ten decompressive craniectomy patients. The shape-based interpolation method was used, in which the technique of segmenting every fifth and tenth slice of CT data was performed. The final design of patient-specific implants from both software was exported to STL format for analysis. The results of the Kruskal–Wallis test for the surface and volume of cranial implants designed using 3-matic and the two MITK techniques showed no significant difference, p > 0.05. The results of the Hausdorff Distance (HD) and Dice Similarity Coefficient (DSC) analyses for cranial implants designed using 3-matic software and the two different MITK techniques showed that the average points distance for 3-matic versus MITK was 0.28 mm (every tenth slice) and 0.15 mm (every fifth slice), and the similarity between 3-matic and MITK on every tenth and fifth slices were 85.1% and 89.7%, respectively. The results also showed that the open-source MITK software is comparable with the commercial software for designing patient-specific implants.

1 September 2009 in Journal of Forensic Sciences
Verified
Journal Article
Closed access
PDF file
HHHelmi Hadi
Helmi Hadi
PJPaul T. Jayaprakash
Paul T. Jayaprakash