Henrique Ribeiro

Prof. Henrique Ribeiro

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2013 in JACC
Verified
Journal Article
Closed access
HRHenrique Ribeiro
Henrique Ribeiro
JWJohn G. Webb
John G. Webb
RMRaj R. Makkar
Raj R. Makkar
MCMauricio G. Cohen
Mauricio G. Cohen
SKSamir R. Kapadia
Samir R. Kapadia
JRJosep Rodés-Cabau
Josep Rodés-Cabau

16 July 2013 in Circulation
Verified
Journal Article
Closed access
MBMarco Barbanti
Marco Barbanti
TYTae-Hyun Yang
Tae-Hyun Yang
JCJosep Rodès Cabau
Josep Rodès Cabau
CTCorrado Tamburino
Corrado Tamburino
DWDavid A. Wood
David A. Wood
JLJonathon Leipsic
Jonathon Leipsic
Background—: Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. Methods and Results—: Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters and cross-sectional area of the sinotubular junction, annulus, and LVOT, and the presence, location, and extent of calcification of the LVOT, as well. There were no significant differences between the 2 groups in any preoperative clinical and echocardiographic variables. Aortic root rupture was identified in 20 patients and periaortic hematoma in 11. Patients with root rupture had a higher degree of subannular/LVOT calcification quantified by the Agatston score (181.2±211.0 versus 22.5±37.6, P <0.001), and a higher frequency of ≥20% annular area oversizing (79.4% versus 29.0%, P <0.001) and balloon postdilatation (22.6% versus 0.0%, P =0.005). In conditional logistic regression analysis for the matched data, moderate/severe LVOT/subannular calcifications (odds ratio, 10.92; 95% confidence interval, 3.23–36.91; P <0.001) and prosthesis oversizing ≥20% (odds ratio, 8.38; 95% confidence interval, 2.67–26.33; P <0.001) were associated with aortic root contained/noncontained rupture. Conclusions—: This study demonstrates that LVOT calcification and aggressive annular area oversizing are associated with an increased risk of aortic root rupture during TAVR with balloon-expandable prostheses. Larger studies are warranted to confirm these findings.

14 August 2017 in European Heart Journal
Verified
Journal Article
Open access
PDF file
HRHenrique Ribeiro
Henrique Ribeiro
JRJosep Rodés-Cabau
Josep Rodés-Cabau
PBPhilipp Blanke
Philipp Blanke
JLJonathon Leipsic
Jonathon Leipsic
JPJong Kwan Park
Jong Kwan Park
DDDanny Dvir
Danny Dvir
There are limited data on coronary obstruction following transcatheter valve-in-valve (ViV) implantation inside failed aortic bioprostheses. The objectives of this study were to determine the incidence, predictors, and clinical outcomes of coronary obstruction in transcatheter ViV procedures. A total of 1612 aortic procedures from the Valve-in-Valve International Data (VIVID) Registry were evaluated. Data were subject to centralized blinded corelab computed tomography (CT) analysis in a subset of patients. The virtual transcatheter valve to coronary ostium distance (VTC) was determined. A total of 37 patients (2.3%) had clinically evident coronary obstruction. Baseline clinical characteristics in the coronary obstruction patients were similar to controls. Coronary obstruction was more common in stented bioprostheses with externally mounted leaflets or stentless bioprostheses than in stented with internally mounted leaflets bioprostheses (6.1% vs. 3.7% vs. 0.8%, respectively; P < 0.001). CT measurements were obtained in 20 (54%) and 90 (5.4%) of patients with and without coronary obstruction, respectively. VTC distance was shorter in coronary obstruction patients in relation to controls (3.24 ± 2.22 vs. 6.30 ± 2.34, respectively; P < 0.001). Using multivariable analysis, the use of a stentless or stented bioprosthesis with externally mounted leaflets [odds ratio (OR): 7.67; 95% confidence interval (CI): 3.14–18.7; P < 0.001] associated with coronary obstruction for the global population. In a second model with CT data, a shorter VTC distance predicted this complication (OR: 0.22 per 1 mm increase; 95% CI: 0.09–0.51; P < 0.001), with an optimal cut-off level of 4 mm (area under the curve: 0.943; P < 0.001). Coronary obstruction was associated with a high 30-day mortality (52.9% vs. 3.9% in the controls, respectively; P < 0.001). Coronary obstruction following aortic ViV procedures is a life-threatening complication that occurred more frequently in patients with prior stentless or stented bioprostheses with externally mounted leaflets and in those with a short VTC.

13 September 2016 in JAMA
Verified
Journal Article
Open access
PDF file
ARAnder Regueiro
Ander Regueiro
ALAxel Linke
Axel Linke
Azeem LatibAzeem Latib
Azeem Latib
NINikolaj Ihlemann
Nikolaj Ihlemann
MUMarina Urena
Marina Urena
JRJosep Rodés-Cabau
Josep Rodés-Cabau
Infective endocarditis following surgical valve replacement occurs in 1% to 6% of patients and is associated with high morbidity and mortality.1 Transcatheter aortic valve replacement (TAVR) has emerged as a therapeutic option for patients with aortic stenosis who are considered to be at high or prohibitive surgical risk.2 The rate of infective endocarditis within the year following TAVR has been reported to be 1.5%, ranging from 0.5% to 3.1%,3,4 similar to infective endocarditis rates after surgical valve replacement.5,6 Greater exposure to health care procedures, older age, and a considerable amount of foreign material (eg, stent struts) of the transcatheter valve prostheses may have contributed to increase the risk of infective endocarditis in such patients. To date, data on infective endocarditis after TAVR have been limited to case reports and relatively small series with limited follow-up,3,4,7-10 demonstrating in-hospital complication and mortality rates as high as 87% and 47%, respectively. Valve explantation rates in such patients remain relatively low (<10%). It is therefore relevant to further investigate the factors associated with and the clinical characteristics and outcomes of infective endocarditis after TAVR.

1 May 2013 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
HRHenrique Ribeiro
Henrique Ribeiro
LNLuis Nombela-Franco
Luis Nombela-Franco
MUMarina Urena
Marina Urena
MMMichael Mok
Michael Mok
SPSergio Pasian
Sergio Pasian
JRJosep Rodés-Cabau
Josep Rodés-Cabau

18 March 2014 in Circulation
Verified
Journal Article
Closed access
MUMarina Urena
Marina Urena
JWJohn G. Webb
John G. Webb
CTCorrado Tamburino
Corrado Tamburino
AMAntonio J. Muñoz-García
Antonio J. Muñoz-García
ACAsim Cheema
Asim Cheema
JRJosep Rodés-Cabau
Josep Rodés-Cabau
Background—: Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. Methods and Results—: A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74–1.30; P =0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56–1.17; P =0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77–1.30; P =0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11–0.85; P =0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time ( P =0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, −2.26; 95% confidence interval, −4.07 to −0.44; P =0.013; R 2 =0.121). Conclusions—: The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.