Various commercial auto-contouring solutions have emerged over past few years to address labor-intensiveness, and inter- and intra-operator variabilities issues of traditional manual anatomy contouring for head and neck (H&N) radiation therapy (RT). The purpose of this study is to compare the clinical performances between RaySearch Laboratories deep learning (DL) and atlas-based auto-contouring tools for organs at risk (OARs) segmentation in the H&N RT with the manual contouring as reference. Forty-five H&N computed tomography datasets were used for the DL and atlas-based auto-contouring tools to contour 16 OARs and time required for the segmentation was measured. Dice similarity coefficient (DSC), Hausdorff distance (HD) and HD 95th-percentile (HD95) were used to evaluate geometric accuracy of OARs contoured by the DL and atlas-based auto-contouring tools. Paired sample t-test was employed to compare the mean DSC, HD, HD95, and contouring time values of the two groups. The DL auto-contouring approach achieved more consistent performance in OARs segmentation than its atlas-based approach, resulting in statistically significant time reduction of the whole segmentation process by 40% (p < 0.001). The DL auto-contouring had statistically significantly higher mean DSC and lower HD and HD95 values (p < 0.001–0.009) for 10 out of 16 OARs. This study proves that the RaySearch Laboratories DL auto-contouring tool has significantly better clinical performances than its atlas-based approach.
This study retrospectively evaluates clinical outcomes of dose escalation to involved nodes using volumetric modulated arc therapy (VMAT) with simultaneous integrated boost (SIB) for node-positive locally advanced cervical cancer (LACC) at a single institution. Consecutive patients with node-positive LACC (FIGO2018 IIIC1-IVA) who received definitive chemoradiotherapy by VMAT 45 Gy in 25 fractions with SIB to 55–57.5 Gy, followed by magnetic resonance image-guided adaptive brachytherapy (IGABT) between 2018 and 2022 were identified. A standardized strategy regarding nodal boost delivery and elective para-aortic (PAO) irradiation was employed. Primary endpoints were involved nodal control (INC) and regional nodal control (RNC). Secondary endpoints were pelvic control (PC), locoregional control (LRC), disease-free survival (DFS), overall survival (OS), failure pattern, and radiotherapy-related toxicities. A total of 234 involved nodes (182 pelvic and 52 PAO) in 54 patients, with a median of 3 involved nodes per patient (range 1–16), were analyzed. After a median follow-up of 19.6 months, excellent INC was achieved, with four (2%) boost-volume failures occurring in three patients. The 2-year actuarial RNC, PC, LRC, DFS, and OS were 93%, 87%, 87%, 78%, and 85%, respectively. Adenocarcinoma histology was associated with worse RNC (p = 0.02) and OS (p = 0.04), whereas the primary tumor maximum standardized uptake value (SUVmax) was associated with worse PC (p = 0.04) and LRC (p = 0.046) on univariate analysis. The incidence of grade ≥3 acute and late radiotherapy-related toxicity were 2% and 4%, respectively. Treatment of node-positive LACC with VMAT with SIB allows safe and effective dose escalation. The 5-year local experience demonstrated excellent treatment outcomes without additional toxicity.
Multi-criteria optimization (MCO) function has been available on commercial radiotherapy (RT) treatment planning systems to improve plan quality; however, no study has compared Eclipse and RayStation MCO functions for prostate RT planning. The purpose of this study was to compare prostate RT MCO plan qualities in terms of discrepancies between Pareto optimal and final deliverable plans, and dosimetric impact of final deliverable plans. In total, 25 computed tomography datasets of prostate cancer patients were used for Eclipse (version 16.1) and RayStation (version 12A) MCO-based plannings with doses received by 98% of planning target volume having 76 Gy prescription (PTV76D98%) and 50% of rectum (rectum D50%) selected as trade-off criteria. Pareto optimal and final deliverable plan discrepancies were determined based on PTV76D98% and rectum D50% percentage differences. Their final deliverable plans were compared in terms of doses received by PTV76 and other structures including rectum, and PTV76 homogeneity index (HI) and conformity index (CI), using a t-test. Both systems showed discrepancies between Pareto optimal and final deliverable plans (Eclipse: −0.89% (PTV76D98%) and −2.49% (Rectum D50%); RayStation: 3.56% (PTV76D98%) and −1.96% (Rectum D50%)). Statistically significantly different average values of PTV76D98%,HI and CI, and mean dose received by rectum (Eclipse: 76.07 Gy, 0.06, 1.05 and 39.36 Gy; RayStation: 70.43 Gy, 0.11, 0.87 and 51.65 Gy) are noted, respectively (p < 0.001). Eclipse MCO-based prostate RT plan quality appears better than that of RayStation.
A previous study investigated robustness of manual flash (MF) and robust optimized (RO) volumetric modulated arc therapy plans for breast radiotherapy based on five patients in 2020 and indicated that the RO was more robust than the MF, although the MF is still current standard practice. The purpose of this study was to compare their plan robustness in terms of dose variation to clinical target volume (CTV) and organs at risk (OARs) based on a larger sample size. This was a retrospective study involving 34 female patients. Their plan robustness was evaluated based on measured volume/dose difference between nominal and worst scenarios (ΔV/ΔD) for each CTV and OARs parameter, with a smaller difference representing greater robustness. Paired sample t-test was used to compare their robustness values. All parameters (except CTV ΔD98%) of the RO approach had smaller ΔV/ΔD values than those of the MF. Also, the RO approach had statistically significantly smaller ΔV/ΔD values (p < 0.001–0.012) for all CTV parameters except the CTV ΔV95% and ΔD98% and heart ΔDmean. This study’s results confirm that the RO approach was more robust than the MF in general. Although both techniques were able to generate clinically acceptable plans for breast radiotherapy, the RO could potentially improve workflow efficiency due to its simpler planning process.
This study retrospectively evaluates the clinical outcomes of definitive volumetric modulated arc therapy (VMAT) for high-risk or very high-risk locoregional prostate cancer patients from an Asian institution. Consecutive patients who received VMAT (76 Gy in 38 fractions) between January 2017 and June 2022 were included. Whole pelvic radiotherapy (WPRT) (46 Gy in 23 fractions) was employed for clinically node-negative disease (cN0) and a Roach estimated risk of ≥15%, as well as simultaneous integrated boost (SIB) of 55–57.5 Gy to node-positive (cN1) disease. The primary endpoint was biochemical relapse-free survival (BRFS). Secondary endpoints included radiographic relapse-free survival (RRFS), metastasis-free survival (MFS) and prostate cancer-specific survival (PCSS). A total of 209 patients were identified. After a median follow-up of 47.5 months, the 4-year actuarial BRFS, RRFS, MFS and PCSS were 85.2%, 96.8%, 96.8% and 100%, respectively. The incidence of late grade ≥ 2 genitourinary (GU) and gastrointestinal (GI) toxicity were 15.8% and 11.0%, respectively. No significant difference in cancer outcomes or toxicity was observed between WPRT and prostate-only radiotherapy for cN0 patients. SIB to the involved nodes did not result in increased toxicity. International Society of Urological Pathology (ISUP) group 5 and cN1 stage were associated with worse RRFS (p < 0.05). PSMA PET-CT compared to conventional imaging staging was associated with better BRFS in patients with ISUP grade group 5 (p = 0.039). Five-year local experience demonstrates excellent clinical outcomes. PSMA PET-CT staging for high-grade disease and tailored pelvic irradiation based on nodal risk should be considered to maximize clinical benefit.