Alfredo Rodriguez

Prof. Alfredo Rodriguez

Universidad Autonoma Metropolitana Iztapalapa
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
JGJulio Garcia
Julio Garcia
OMOscar R Marrufo
Oscar R Marrufo
Alfredo RodriguezAlfredo Rodriguez
Alfredo Rodriguez
ELEric Larose
Eric Larose
PPPhilippe Pibarot
Philippe Pibarot
LKLyes Kadem
Lyes Kadem
Transthoracic echocardiography (TTE) is the standard method for the evaluation of the severity of aortic stenosis (AS). Valve effective orifice area (EOA) measured by the continuity equation is one of the most frequently used stenotic indices. However, TTE measurement of aortic valve EOA is not feasible or not reliable in a significant proportion of patients. Cardiovascular magnetic resonance (CMR) has emerged as a non-invasive alternative to evaluate EOA using velocity measurements. The objectives of this study were: 1) to validate a new CMR method using jet shear layer detection (JSLD) based on acoustical source term (AST) concept to estimate the valve EOA; 2) to introduce a simplified JSLD method not requiring vorticity field derivation.

25 November 2013 in Sensors
Verified
Journal Article
Open access
PDF file
FDFloriberto Díaz-Díaz
Floriberto Díaz-Díaz
PCPrisciliano F. De J. Cano-Barrita
Prisciliano F. De J. Cano-Barrita
BBBruce J. Balcom
Bruce J. Balcom
SSSergio E. Solís-Nájera
Sergio E. Solís-Nájera
Alfredo RodriguezAlfredo Rodriguez
Alfredo Rodriguez
In cement-based materials porosity plays an important role in determining their mechanical and transport properties. This paper describes an improved low–cost embeddable miniature NMR sensor capable of non-destructively measuring evaporable water loss and porosity refinement in low and high water-to-cement ratio cement-based materials. The sensor consists of two NdFeB magnets having their North and South poles facing each other, separated by 7 mm to allow space for a Faraday cage containing a Teflon tube and an ellipsoidal RF coil. To account for magnetic field changes due to temperature variations, and/or the presence of steel rebars, or frequency variation due to sample impedance, an external tuning circuit was employed. The sensor performance was evaluated by analyzing the transverse magnetization decay obtained with a CPMG measurement from different materials, such as a polymer phantom, fresh white and grey cement pastes with different w/c ratios and concrete with low (0.30) and high (0.6) w/c ratios. The results indicated that the sensor is capable of detecting changes in water content in fresh cement pastes and porosity refinement caused by cement hydration in hardened materials, even if they are prepared with a low w/c ratio (w/c = 0.30). The short lifetime component of the transverse relaxation rate is directly proportional to the compressive strength of concrete determined by destructive testing. The r2 (0.97) from the linear relationship observed is similar to that obtained using T2 data from a commercial Oxford Instruments 12.9 MHz spectrometer.

7 November 2006 in Concepts in Magnetic Resonance Part A
Verified
Journal Article
Closed access
PDF file
KOK. Ocegueda
K. Ocegueda
Alfredo RodriguezAlfredo Rodriguez
Alfredo Rodriguez

8 October 2015 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Closed access
PDF file
SSSergio E. Solis-Najera
Sergio E. Solis-Najera
RMRodrigo Martin
Rodrigo Martin
FVFabian Vazquez
Fabian Vazquez
Alfredo RodriguezAlfredo Rodriguez
Alfredo Rodriguez

31 August 2005 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
Alfredo RodriguezAlfredo Rodriguez
Alfredo Rodriguez
LMLucía Medina
Lucía Medina
A computational comparison of signal-to-noise ratio (SNR) was performed between a conventional phased array of two circular-shaped coils and a petal resonator surface array. The quasi-static model and phased-array optimum SNR were combined to derive an SNR formula for each array. Analysis of mutual inductance between coil petals was carried out to compute the optimal coil separation and optimum number of petal coils. Mutual interaction between coil arrays was not included in the model because this does not drastically affect coil performance. Phased arrays of PERES coils show a 114% improvement in SNR over that of the simplest circular configuration.

1 August 2007 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
RRR. Rojas
R. Rojas
Alfredo RodriguezAlfredo Rodriguez
Alfredo Rodriguez
An image based method to compute the signal to noise ratio and specific energy absorption rate of MRI surface resonator coil for different polygonal geometries is proposed. A commercial software tool based on the Finite Element Method was used to numerically solve the Maxwell's equations to form bidimensional images of the electric and magnetic fields. These images represent the point by point fields inside the surface coil. With this data, MATLAB specifically written programs were used to numerically compute the signal to noise ratio and the specific absorption rate for different surface coil geometries. Bidimensional images and contours of the signal to noise ratio and specific absorption rate were also computed and compared. Uniformity profiles of various geometries were calculated using the resulting data to determine the optimal field uniformity. According to the signal to noise ratio images, the squared shaped coil shows the most suitable uniformity for magnetic resonance imaging applications. This can be a good candidate for phased array imaging and parallel imaging.