LEONARDO MORAIS DA SILVA

Prof. Dr. LEONARDO MORAIS DA SILVA

Federal University of Jequitinhonha and Mucurí Valleys (UFVJM)
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2001 in Electrochimica Acta
Verified
Journal Article
Closed access
LEONARDO MORAIS DA SILVALEONARDO MORAIS DA SILVA
LEONARDO MORAIS DA SILVA
LFL.A De Faria
L.A De Faria
JBJ.F.C Boodts
J.F.C Boodts

1 February 2001 in Electrochimica Acta
Verified
Journal Article
Closed access
LEONARDO MORAIS DA SILVALEONARDO MORAIS DA SILVA
LEONARDO MORAIS DA SILVA
JBJ.F.C. Boodts
J.F.C. Boodts
LFL.A. De Faria
L.A. De Faria

1 February 2003 in Electrochimica Acta
Verified
Journal Article
Closed access
LEONARDO MORAIS DA SILVALEONARDO MORAIS DA SILVA
LEONARDO MORAIS DA SILVA
LFLuiz A. De Faria
Luiz A. De Faria
JBJulien F.C. Boodts
Julien F.C. Boodts

12 April 2019 in Molecules
Verified
Journal Article
Open access
PDF file
RVRafael Vicentini
Rafael Vicentini
LEONARDO MORAIS DA SILVALEONARDO MORAIS DA SILVA
LEONARDO MORAIS DA SILVA
EJEdson Pedro Cecilio Junior
Edson Pedro Cecilio Junior
TAThayane Almeida Alves
Thayane Almeida Alves
WNWillian Nunes
Willian Nunes
HZHudson Zanin
Hudson Zanin
Electric double-layer capacitors (EDLCs) are energy storage devices that have attracted attention from the scientific community due to their high specific power storage capabilities. The standard method for determining the maximum power (Pmax) of these devices uses the relation Pmax = U2/4RESR, where U stands for the cell voltage and RESR for the equivalent series resistance. Despite the relevance of RESR, one can observe a lack of consensus in the literature regarding the determination of this parameter from the galvanostatic charge-discharge findings. In addition, a literature survey revealed that roughly half of the scientific papers have calculated the RESR values using the electrochemical impedance spectroscopy (EIS) technique, while the other half used the galvanostatic charge discharge (GCD) method. RESR values extracted from EIS at high frequencies (>10 kHz) do not depend on the particular equivalent circuit model. However, the conventional GCD method better resembles the real situation of the device operation, and thus its use is of paramount importance for practical purposes. In the latter case, the voltage drop (ΔU) verified at the charge-discharge transition for a given applied current (I) is used in conjunction with Ohm’s law to obtain the RESR (e.g., RESR = ΔU/ΔI). However, several papers have caused a great confusion in the literature considering only applied current (I). In order to shed light on this important subject, we report in this work a rational analysis regarding the GCD method in order to prove that to obtain reliable RESR values the voltage drop must be normalized by a factor of two (e.g., RESR = ΔU/2I).

1 September 2004 in Electrochimica Acta
Verified
Journal Article
Closed access
LEONARDO MORAIS DA SILVALEONARDO MORAIS DA SILVA
LEONARDO MORAIS DA SILVA
DFDébora V. Franco
Débora V. Franco
LFLuiz A. De Faria
Luiz A. De Faria
JBJulien F.C. Boodts
Julien F.C. Boodts

5 November 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
WNWillian G. Nunes
Willian G. Nunes
BFBruno G. A. Freitas
Bruno G. A. Freitas
RBRenato M. Beraldo
Renato M. Beraldo
RFRubens Maciel Filho
Rubens Maciel Filho
LEONARDO MORAIS DA SILVALEONARDO MORAIS DA SILVA
LEONARDO MORAIS DA SILVA
HZHudson Zanin
Hudson Zanin
It is common to find in the literature different values for the working voltage window (WVW) range for aqueous-based supercapacitors. In many cases, even with the best intentions of the widening the operating voltage window, the measured current using the cyclic voltammetry (CV) technique includes a significant contribution from the irreversible Faradaic reactions involved in the water-splitting process, masked by fast scan rates. Sometimes even using low scan rates is hard to determine precisely the correct WVW of the aqueous-based electrochemical capacitor. In this sense, we discuss here the best practices to determine the WVW for capacitive current in an absence of water splitting using complementary techniques such as CV, chronoamperometry (CA), and the electrochemical impedance spectroscopy (EIS). To accomplish this end, we prepare and present a model system composed of multiwalled carbon nanotubes buckypaper electrodes housed in the symmetric coin cell and soaked with an aqueous-based electrolyte. The system electrochemical characteristics are carefully evaluated during the progressive enlargement of the cell voltage window. The presence of residual Faradaic current is verified in the transients from the CA study, as well as the impedance changes revealed by EIS as a function of the applied voltage, is discussed. We verify that an apparent voltage window of 2.0 V determined using the CV technique is drastically decreased to 1.2 V after a close inspection of the CA findings used to discriminate the presence of a parasitic Faradaic process. Some orientations are presented to instigate the establishment in the literature of some good scientific practices concerned with the reliable characterization of supercapacitors.