Lemiao Qiu

Dr. Lemiao Qiu

Zhejiang University
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2023 in Expert Systems with Applications
Verified
Journal Article
Closed access
FXFeifan Xiang
Feifan Xiang
YZYiming Zhang
Yiming Zhang
SZShuyou Zhang
Shuyou Zhang
Zili WangZili Wang
Zili Wang
LQLemiao Qiu
Lemiao Qiu
JCJoo-Ho Choi
Joo-Ho Choi

25 October 2024
Verified
Book Chapter
Closed access
PDF file
ZZZheyuan Zhou
Zheyuan Zhou
LWLe Wang
Le Wang
NFNaiyu Fang
Naiyu Fang
ZWZili Wang
Zili Wang
LQLemiao Qiu
Lemiao Qiu
SZShuyou Zhang
Shuyou Zhang

22 September 2021 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
ZWZili Wang
Zili Wang
YLYaochen Lin
Yaochen Lin
LQLemiao Qiu
Lemiao Qiu
SZShuyou Zhang
Shuyou Zhang
DFDingyu Fang
Dingyu Fang
LWLe Wang
Le Wang

22 June 2024 in Expert Systems with Applications
Verified
Journal Article
Closed access
ZWZili Wang
Zili Wang
CWCaicheng Wang
Caicheng Wang
SZShuyou Zhang
Shuyou Zhang
LQLemiao Qiu
Lemiao Qiu
YLYaochen Lin
Yaochen Lin
CSChang Sun
Chang Sun

13 February 2020 in Shock and Vibration
Verified
Journal Article
Open access
LQLemiao Qiu
Lemiao Qiu
Zili WangZili Wang
Zili Wang
SZShuyou Zhang
Shuyou Zhang
LZLichun Zhang
Lichun Zhang
JCJie Chen
Jie Chen
High-speed elevator horizontal vibration (HsEHV) is a problem that seriously affects ride comfort. To solve this problem, a design parameter optimization method for HsEHV reduction was studied. A dynamic equation of HsEHV was established, and its response value was calculated using a precise integration method. The influence of the design parameters on horizontal vibration was also analyzed. An optimization model of the design parameters for HsEHV reduction was constructed, and the response surface model of objective function (the peak-to-peak value of horizontal vibration acceleration) was constructed using Latin hypercube sampling. We adopted a multiobjective genetic algorithm to optimize the design parameters for horizontal vibration reduction and used the min-max standardization method to select an optimal solution set. Finally, a KLK2 high-speed elevator made by Canny Elevator Co., Ltd., was utilized as an example to analyze the influencing factors of HsEHV, optimize the design parameters to reduce horizontal vibration, and verify the optimized results using numerical calculation and prototype testing.

26 April 2022 in Journal of Vibration and Control
Verified
Journal Article
Closed access
Zili WangZili Wang
Zili Wang
LQLemiao Qiu
Lemiao Qiu
SZShuyou Zhang
Shuyou Zhang
GSGuannan Su
Guannan Su
LZLinhao Zhu
Linhao Zhu
XZXuewei Zhang
Xuewei Zhang
As the field of modern high-rise buildings advances, the demand for the high-speed elevator increases. The high-speed elevator car vibration directly affects the riding comforts, among which the high-speed elevator car horizontal vibration has the most pronounced effect. Previous researches indicate that the semi-active vibration reduction method is an effective horizontal vibration reduction method for elevator car, which has the characteristics of low energy consumption, suitable for high-speed elevator, while its adaptability is relatively weak. To address the adaptability issue, we proposed a semi-active high-speed elevator car horizontal vibration reduction method based on the improved particle swarm algorithm. To verify the feasibility of the proposed method, it is applied with a magneto-rheological damper in the KLK2-type elevator from Canny Elevator Co, Ltd The horizontal vibration results are compared with ones of the passive vibration reduction method and other algorithm-based vibration reduction methods. The vibration reduction method proposed in this paper is superior to all other mentioned methods in terms of the peak-to-peak value and the A95 value of the vibration acceleration. The horizontal vibration acceleration performance of the HSEC is improved by about 70%.