Mati Ullah Shah

Mr. Mati Ullah Shah

School of Civil and Environmental Engineering, National University of Sciences and Technology,Pakistan
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2023 in Materials
Verified
Journal Article
Open access
PDF file
Ammar AliAmmar Ali
Ammar Ali
RRRaja Dilawar Riaz
Raja Dilawar Riaz
Umair Jalil MalikUmair Jalil Malik
Umair Jalil Malik
SASyed Baqar Abbas
Syed Baqar Abbas
Muhammad UsmanMuhammad Usman
Muhammad Usman
FMFaizan Muhammad
Faizan Muhammad
The additive manufacturing of concrete, also known as 3D-printed concrete, is produced layer by layer using a 3D printer. The three-dimensional printing of concrete offers several benefits compared to conventional concrete construction, such as reduced labor costs and wastage of materials. It can also be used to build complex structures with high precision and accuracy. However, optimizing the mix design of 3D-printed concrete is challenging, involving numerous factors and extensive hit-and-trail experimentation. This study addresses this issue by developing predictive models, such as the Gaussian Process Regression model, Decision Tree Regression model, Support Vector Machine model, and XGBoost Regression models. The input parameters were water (Kg/m3), cement (Kg/m3), silica fume (Kg/m3), fly ash (Kg/m3), coarse aggregate (Kg/m3 & mm for diameter), fine aggregate (Kg/m3 & mm for diameter), viscosity modifying agent (Kg/m3), fibers (Kg/m3), fiber properties (mm for diameter and MPa for strength), print speed (mm/sec), and nozzle area (mm2), while target properties were the flexural and tensile strength of concrete (MPa data from 25 literature studies were collected. The water/binder ratio used in the dataset ranged from 0.27 to 0.67. Different types of sands and fibers have been used, with fibers having a maximum length of 23 mm. Based upon the Coefficient of Determination (R2), Root Mean Square Error (RMSE), Mean Square Error (MSE), and Mean Absolute Error (MAE) for casted and printed concrete, the SVM model performed better than other models. All models’ cast and printed flexural strength values were also correlated. The model’s performance has also been checked on six different mix proportions from the dataset to show its accuracy. It is worth noting that the lack of ML-based predictive models for the flexural and tensile properties of 3D-printed concrete in the literature makes this study a novel innovation in the field. This model could reduce the computational and experimental effort required to formulate the mixed design of printed concrete.

27 February 2021 in Materials
Verified
Journal Article
Open access
PDF file
Mati Ullah ShahMati Ullah Shah
Mati Ullah Shah
Muhammad UsmanMuhammad Usman
Muhammad Usman
MHMuhammad Usman Hanif
Muhammad Usman Hanif
INIqra Naseem
Iqra Naseem
SFSara Farooq
Sara Farooq
The huge amount of solid waste from the brick manufacturing industry can be used as a cement replacement. However, replacement exceeding 10% causes a reduction in strength due to the slowing of the pozzolanic reaction. Therefore, in this study, the pozzolanic potential of brick waste is enhanced using ultrafine brick powder with hydrated lime (HL). A total of six self-compacting paste mixes were studied. HL 2.5% by weight of binder was added in two formulations: 10% and 20% of waste burnt brick powder (WBBP), to activate the pozzolanic reaction. An increase in the water demand and setting time was observed by increasing the replacement percentage of WBBP. It was found that the mechanical properties of mixes containing 5% and 10% WBBP performed better than the control mix, while the mechanical properties of the mixes containing 20% WBBP were found to be almost equal to the control mix at 90 days. The addition of HL enhanced the early-age strength. Furthermore, WBBP formulations endorsed improvements in both durability and rheological properties, complemented by reduced early-age shrinkage. Overall, it was found that brick waste in ultrafine size has a very high degree of pozzolanic potential and can be effectively utilized as a supplementary cementitious material.

17 April 2023 in Actuators
Verified
Journal Article
Open access
PDF file
RRRaja Dilawar Riaz
Raja Dilawar Riaz
Umair Jalil MalikUmair Jalil Malik
Umair Jalil Malik
Mati Ullah ShahMati Ullah Shah
Mati Ullah Shah
Muhammad UsmanMuhammad Usman
Muhammad Usman
FNFawad Ahmed Najam
Fawad Ahmed Najam
After the catastrophic destruction of the October 2005 Kashmir earthquake, the first building code of Pakistan was developed in 2007. The sole purpose of the building code of Pakistan (BCP) was to incorporate advancements in earthquake-resistant design to fortify structures and ensure the safety of citizens against future seismic events. After 2007, the BCP was not revised till 2021 to include the changes over time. However, the recently updated version of BCP 2021 highlights that the seismicity of many regions in Pakistan is high, which is not truly reflected in the BCP 2007. Therefore, the advancements in earthquake-resistant design due to the growing concerns about the potential risks of seismicity in the region have been incorporated into the updated version of the BCP. However, there are concerns among researchers that many structures designed on the 2007 code may need seismic fortification. Therefore, the current study focuses on the seismic fortification of existing systems that were developed using previous codes. Non-linear viscous fluid dampers are used to improve the seismic resilience of existing structures. This study compares the seismic performance of an existing reinforced concrete building with and without non-linear viscous dampers and subjected to a non-linear dynamic analysis. The performance of the building is evaluated in terms of story displacement, story drift, story acceleration, and energy dissipation mechanisms. Adding the non-linear fluid viscous dampers in the structure caused a decrease in the inter-story drift by around 31.16% and the roof displacement was reduced by around 36.58%. In addition to that, in a controlled structure, more than 70% of energy was dissipated by the fluid viscous dampers. These results indicate that adding the non-linear fluid viscous dampers to the existing structure significantly improved the vibration performance of the system against undesirous vibrations. The outcomes of this study also provide a very detailed insight into the usage of non-linear viscous dampers for improving the seismic performance of existing buildings and can be used to develop effective strategies to mitigate the impact of seismic events on already built structures.

13 November 2022 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
Mati Ullah ShahMati Ullah Shah
Mati Ullah Shah
Muhammad UsmanMuhammad Usman
Muhammad Usman
SFSyed Hassan Farooq
Syed Hassan Farooq
MRMuhammad Rizwan
Muhammad Rizwan

13 June 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Mati Ullah ShahMati Ullah Shah
Mati Ullah Shah
Muhammad UsmanMuhammad Usman
Muhammad Usman
A tuned liquid column damper (TLCD) is a passive vibration control device that not only mitigates unwanted structural vibrations but also acts as a water storage facility in a building. These aspects of TLCD make its application specifically suited for building structures. Previously, many experimental works on TLCDs have been conducted considering a single degree of freedom (SDOF) structure. However, the performance of TLCDs to control the response of multi-degree of freedom (MDOF) structure has rarely been studied experimentally. Therefore, this study has investigated the performance of a tuned liquid column damper (TLCD) on a multi-degree of freedom (MDOF) structure using shake table testing. A four-storey steel frame structure equipped with TLCD at the top of the fourth storey has been studied. Experimental normalized frequency response curves for MDOF structure equipped with TLCD have been determined. For this purpose, a series of harmonic loadings including frequencies 0.65 Hz, 1.17 Hz, 1.30 Hz, 1.43 Hz and 1.95 Hz have been applied in addition to historic earthquake loading. Peak and root-mean-square (RMS) accelerations have been discussed in detail for all the applied loadings at each storey level of the structure. For comparison purposes, the percentage reductions in peak and RMS accelerations have been calculated and compared. Also, RMS displacements and inter-storey drifts have been presented for resonant and seismic excitations. Both in time and frequency domains, responses of controlled MDOF structure have been analyzed and compared with uncontrolled structure. Results confirmed that TLCD has improved the MDOF structure responses at harmonic loadings frequencies near resonance and historic earthquake excitations. Furthermore, the improvement in the responses of MDOF structure with TLCD is more prominent at harmonic loadings compared to historic earthquake loading.

29 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Mati Ullah ShahMati Ullah Shah
Mati Ullah Shah
Muhammad UsmanMuhammad Usman
Muhammad Usman
SFSyed Hassan Farooq
Syed Hassan Farooq
IKInho Kim
Inho Kim
This paper reports the theoretical findings of the new modified type of tuned liquid column ball damper (TLCBD), called a tuned liquid column ball spring damper (TLCBSD). In this new modified form, the ball inside the horizontal section of the damper is attached to the spring. Furthermore, two types of this modified version are proposed, known as a tuned liquid column ball spring sliding damper (TLCBSSD) and a tuned liquid column ball spring rolling damper (TLCBSRD). In the former, the rotational motion of the ball attached to the spring is restricted, whereas in the latter, the ball attached to the spring can translate as well as rotate. Mathematical models and optimum design parameters are formulated for both types. The performance of these new modified damper versions is assessed numerically and subjected to harmonic, seismic, and impulse loadings. The results show that the performance of the newly proposed dampers is relatively better than traditional TLCBDs in harmonic and seismic excitations. The peak response reduction soon after the impact load becomes zero is comparatively better in TLCBSDs over TLCBDs. Overall, the newly proposed passive vibration control devices performed excellently in structure response reduction over TLCBDs.