Valérie Gaudin

Dr. Valérie Gaudin

ANSES (National Agency for Food, Environmental and Occupational Health Safety)
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

26 September 2012 in Food Additives & Contaminants: Part A
Verified
Journal Article
Closed access
Valérie GaudinValérie Gaudin
Valérie Gaudin
CHCeline Hedou
Celine Hedou
EVEric Verdon
Eric Verdon
Antibiotics are mixed with the food of bees to fight against diseases. No maximum residue limits have been set for honey. Recommended concentrations (RCs) have been published by European Union Reference Laboratories for tylosin and streptomycin. The objective of this project was to select and validate enzyme-linked immunosorbent assay (ELISA) kits for the screening of tylosin and streptomycin/dihydrostreptomycin residues to be implemented in the French honey control plan. Four ELISA kits for tylosin and five ELISA kits for streptomycin were evaluated. At the end, one kit each was selected and validated for tylosin (TECNA AB620) and streptomycin (Europroxima). Both ELISA kits for tylosin and streptomycin are specific, robust, fast and easy-to-use tests. The detection capability CCβ of tylosin A was less than or equal to 10 µg kg−1 (half the RC). The CCβ of desmycosin (the hydrolysed product of tylosin A in acidic conditions) is approximately 200 µg kg−1, which is five times the RC for tylosin (20 µg kg−1). Thus, this kit is fit for the screening of tylosin A but is unsuitable to detect desmycosin. The detection capability CCβ of streptomycin was less than or equal to 10 µg kg−1 (one fourth the RC). The cross-reactivity with dihydrostreptomycin was equal to 136%. Both ELISA kits were applicable to a wide variety of honey (single flower and multiflower, different floral origins, different geographic origins, different consistencies [liquid or solid] and different colours).

3 March 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
Valérie GaudinValérie Gaudin
Valérie Gaudin
The presence of antimicrobial residues in food-producing animals can lead to harmful effects on the consumer (e.g., allergies, antimicrobial resistance, toxicological effects) and cause issues in food transformation (i.e., cheese, yogurts production). Therefore, to control antimicrobial residues in food products of animal origin, screening methods are of utmost importance. Microbiological and immunological methods (e.g., ELISA, dipsticks) are conventional screening methods. Biosensors are an innovative solution for the development of more performant screening methods. Among the different kinds of biosensing elements (e.g., antibodies, aptamers, molecularly imprinted polymers (MIP), enzymes), aptamers for targeting antimicrobial residues are in continuous development since 2000. Therefore, this review has highlighted recent advances in the development of aptasensors, which present multiple advantages over immunosensors. Most of the aptasensors described in the literature for the detection of antimicrobial residues in animal-derived food products are either optical or electrochemical sensors. In this review, I have focused on optical aptasensors and showed how nanotechnologies (nanomaterials, micro/nanofluidics, and signal amplification techniques) largely contribute to the improvement of their performance (sensitivity, specificity, miniaturization, portability). Finally, I have explored different techniques to develop multiplex screening methods. Multiplex screening methods are necessary for the wide spectrum detection of antimicrobials authorized for animal treatment (i.e., having maximum residue limits).

3 September 2014 in Food Additives & Contaminants: Part A
Verified
Journal Article
Closed access
Valérie GaudinValérie Gaudin
Valérie Gaudin
CHCeline Hedou
Celine Hedou
CSChristophe Soumet
Christophe Soumet
EVEric Verdon
Eric Verdon
The main chemicals used against varoa are acaricides, and the antibiotics used for the control of bee bacterial diseases are mainly tetracyclines, streptomycins, sulfonamides and chloramphenicol. No maximum residue limits (MRLs) have been set for any antibiotics in honey. Therefore, in the European Union, minimum recommended concentrations (RC) for the analytical performance of methods to control a certain set of these non-authorised chemicals in honey were published by the European Union Reference Laboratory (EU-RL) in 2007. Concerning the strategy for the control for antibiotic residues in honey, there is still a great need for a cheap and single multi-residue method. Biochip array technology is an innovative assay technology for the multi-analyte screening of biological samples in a rapid and easy-to-use format. A multi-array system, called Evidence Investigator™ (Randox, Crumlin, Co., Antrim, UK), was evaluated in our laboratory. It is a semi-automated biochip system designed for research, clinical applications and veterinary use. A competitive chemiluminescent immunoassay is employed for the detection of antimicrobials. The MicroArray II kit (AM II) dedicated to the screening of six different families of antibiotic residues was validated according to the European guideline for the validation of screening methods for residues of veterinary medicines. The specificity was proven to be very satisfactory, and applicability to different kinds of honey was demonstrated. The detection capabilities (CCβ) of six antibiotic residues were determined and were below the RCs when exist. The AM II kit could detect at least six quinolones, four tetracyclines and three epimers, three aminoglycosides, three macrolides, thiamphenicol, florfenicol and ceftiofur along with one of its stabilised metabolites, the desfuroylceftiofurcysteine disulfide (DCCD).

1 March 2013 in Food and Agricultural Immunology
Verified
Journal Article
Open access
Valérie GaudinValérie Gaudin
Valérie Gaudin
ARAnnie Rault
Annie Rault
EVEric Verdon
Eric Verdon
A rapid receptor test dedicated to the screening of tetracycline (TTC) residues, the Tetrasensor® kit in different matrices, has been evaluated and validated according to the European regulation to achieve the French control plan in honey. The detection capabilities (CCβs) were included between 5 and 15 µg kg−1 for chlortetracycline (CTC), oxytetracycline (OTC), TTC and doxycycline (DOXY). The cross-reactions of both kits towards other families of antibiotics were negligible and there was no masking effect of these antibiotics on the detection of tetracyclines. The false positive rate was equal to 9.4%. This kit was applicable to a wide variety of honeys [monofloral and multifloral, different floral origins, different geographical origins and different consistencies (liquid or solid), different colours]. Finally, the Tetrasensor® test is a robust method, quick, easy to perform and easy to read which is now applied to implement the French control plan for the detection of tetracyclines in honey.

6 November 2012 in Food Additives & Contaminants: Part A
Verified
Journal Article
Closed access
Valérie GaudinValérie Gaudin
Valérie Gaudin
ACA. De Courville
A. De Courville
CHC. Hedou
C. Hedou
ARA. Rault
A. Rault
SDS.E. Diomandé
S.E. Diomandé
EVE. Verdon
E. Verdon
Two microbiological kits based on Bacillus stearothermophilus (Eclipse 50® and Premi®Test) have been evaluated and validated according to the European guideline for the validation of screening methods (January 2010) and in relation to the concentrations recommended by the EU-RL in 2007. Both tests are robust, a fast method and easy to implement. Both tests are applicable to a very large variety of honeys from different floral and geographical origins (rosemary, lavender, scrub, heath, alder, forest, lemon, acacia, chestnut, raspberry, mountain and flowers) as well as honey of different colours (from blank honey to brown honey, including yellow and orange honey). A satisfactory false-positive rate of 5% was obtained for the Eclipse 50® test. The observed detection capabilities CCβ of the Eclipse 50® kit were: chlortetracycline (>75 µg kg−1), oxytetracycline (≤200 µg kg−1), tetracycline (>100 µg kg−1), cloxacillin (≤40 µg kg−1), tylosin (≤200 µg kg−1), desmycosin (>400 µg kg−1), sulfadiazine (≤300 µg kg−1), sulfadimethoxine (≤250 µg kg−1), sulfamerazine (>300 µg kg−1), sulfamethazine (>1000 µg kg−1), sulfamethizole (>75 µg kg−1), sulfamethoxazole (≤25 µg kg−1), sulfanilamide (≫1000 µg kg−1), sulfaquinoxaline (>75 µg kg−1), sulfathiazole (≤250 µg kg−1) and lincomycin (>1500 µg kg−1). These levels were all higher than the recommended concentrations where they exist. Due to its lack of sensitivity, it cannot be recommended for reliable routine use. The observed CCβ of the Premi®Test kit were: chlortetracycline (10 µg kg−1), oxytetracycline (>10 µg kg−1), tetracycline (≤10 µg kg−1), cloxacillin (≤5 µg kg−1), tylosin (≤10 µg kg−1), desmycosin (≤15 µg kg−1), sulfadiazine (≤25 µg kg−1), sulfadimethoxine (≤25 µg kg−1), sulfamerazine (≤25 µg kg−1), sulfamethazine (≤25 µg kg−1), sulfamethizole (≤25 µg kg−1), sulfamethoxazole (≤10 µg kg−1), sulfanilamide (≤25 µg kg−1), sulfaquinoxaline (≤10 µg kg−1), sulfathiazole (25 µg kg−1) and lincomycin (≤25 µg kg−1). The Premi®Test kit could be recommended for reliable use in routine control due to its low detection capabilities (except for aminoglycosides), but the disadvantage is a high false-positive rate of 14%.