Martijn Riool

Prof. Dr. Martijn Riool

Amsterdam UMC, location AMC, University of Amsterdam, Department of Medical Microbiology & Infection Prevention
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2018 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
ABAnna de Breij
Anna de Breij
Martijn RioolMartijn Riool
Martijn Riool
RCRobert A. Cordfunke
Robert A. Cordfunke
NMNermina Malanovic
Nermina Malanovic
LBLeonie de Boer
Leonie de Boer
PNPeter H. Nibbering
Peter H. Nibbering
Development of novel antimicrobial agents is a top priority in the fight against multidrug-resistant (MDR) and persistent bacteria. We developed a panel of synthetic antimicrobial and antibiofilm peptides (SAAPs) with enhanced antimicrobial activities compared to the parent peptide, human antimicrobial peptide LL-37. Our lead peptide SAAP-148 was more efficient in killing bacteria under physiological conditions in vitro than many known preclinical- and clinical-phase antimicrobial peptides. SAAP-148 killed MDR pathogens without inducing resistance, prevented biofilm formation, and eliminated established biofilms and persister cells. A single 4-hour treatment with hypromellose ointment containing SAAP-148 completely eradicated acute and established, biofilm-associated infections with methicillin-resistant Staphylococcus aureus and MDR Acinetobacter baumannii from wounded ex vivo human skin and murine skin in vivo. Together, these data demonstrate that SAAP-148 is a promising drug candidate in the battle against antibiotic-resistant bacteria that pose a great threat to human health.

1 September 2017 in Biomaterials
Verified
Journal Article
Closed access
IHIngmar A.J. van Hengel
Ingmar A.J. van Hengel
Martijn RioolMartijn Riool
Martijn Riool
LFLidy E. Fratila-Apachitei
Lidy E. Fratila-Apachitei
JWJanneke Witte-Bouma
Janneke Witte-Bouma
EFEric Farrell
Eric Farrell
Iulian ApachiteiIulian Apachitei
Iulian Apachitei

1 June 2020 in The American Journal of Pathology
Verified
Journal Article
Closed access
MHMarloes I. Hofstee
Marloes I. Hofstee
GMGowrishankar Muthukrishnan
Gowrishankar Muthukrishnan
GAGerald Atkins
Gerald Atkins
Martijn RioolMartijn Riool
Martijn Riool
Keith ThompsonKeith Thompson
Keith Thompson
Fintan  MoriartyFintan Moriarty
Fintan Moriarty

24 August 2017 in Frontiers in Chemistry
Verified
Journal Article
Open access
Martijn RioolMartijn Riool
Martijn Riool
ABAnna de Breij
Anna de Breij
JDJan W. Drijfhout
Jan W. Drijfhout
PNPeter H. Nibbering
Peter H. Nibbering
SZSebastian A.J. Zaat
Sebastian A.J. Zaat
Over the past decades the use of medical devices, such as catheters, artificial heart valves, prosthetic joints and other implants, has grown significantly. Despite continuous improvements in device design, surgical procedures and wound care, biomaterial-associated infections (BAI) are still a major problem in modern medicine. Conventional antibiotic treatment often fails due to the low levels of antibiotic at the site of infection. The presence of biofilms on the biomaterial and/or the multidrug-resistant phenotype of the bacteria further impair the efficacy of antibiotic treatment. Removal of the biomaterial is then the last option to control the infection. Clearly, there is a pressing need for alternative strategies to prevent and treat BAI. Synthetic antimicrobial peptides (AMPs) are considered promising candidates as they are active against a broad spectrum of (antibiotic-resistant) planktonic bacteria and biofilms. Moreover, bacteria are less likely to develop resistance to these rapidly-acting peptides. In this review we highlight the four main strategies, three of which applying AMPs, in biomedical device manufacturing to prevent BAI. The first involves modification of the physicochemical characteristics of the surface of implants. Immobilization of AMPs on surfaces of medical devices with a variety of chemical techniques is essential in the second strategy. The main disadvantage of these two strategies relates to the limited antibacterial effect in the tissue surrounding the implant. This limitation is addressed by the third strategy that releases AMPs from a coating in a controlled fashion. Lastly, AMPs can be integrated in the design and manufacturing of additively manufactured / 3D-printed implants, owing to the physicochemical characteristics of the implant material and the versatile manufacturing technologies compatible with antimicrobials incorporation. These novel technologies utilizing AMPs will contribute to development of novel and safe antimicrobial medical devices, reducing complications and associated costs of device infection.

1 April 2016 in EFORT Open Reviews
Verified
Journal Article
Open access
Fintan  MoriartyFintan Moriarty
Fintan Moriarty
RKRichard Kuehl
Richard Kuehl
TCTom Coenye
Tom Coenye
Willem‐Jan MetsemakersWillem‐Jan Metsemakers
Willem‐Jan Metsemakers
MMMario Morgenstern
Mario Morgenstern
RRR. Geoff Richards
R. Geoff Richards
Orthopaedic and trauma device-related infection (ODRI) remains one of the major complications in modern trauma and orthopaedic surgery. Despite best practice in medical and surgical management, neither prophylaxis nor treatment of ODRI is effective in all cases, leading to infections that negatively impact clinical outcome and significantly increase healthcare expenditure. The following review summarises the microbiological profile of modern ODRI, the impact antibiotic resistance has on treatment outcomes, and some of the principles and weaknesses of the current systemic and local antibiotic delivery strategies. The emerging novel strategies aimed at preventing or treating ODRI will be reviewed. Particular attention will be paid to the potential for clinical impact in the coming decades, when such interventions are likely to be critically important. The review focuses on this problem from an interdisciplinary perspective, including basic science innovations and best practice in infectious disease. Cite this article: Moriarty TF, Kuehl R, Coenye T, et al. Orthopaedic device related infection: current and future interventions for improved prevention and treatment. EFORT Open Rev 2016;1:89-99. DOI: 10.1302/2058-5241.1.000037.

1 January 2016 in Journal of Controlled Release
Verified
Journal Article
Closed access
ABA. de Breij
A. de Breij
Martijn RioolMartijn Riool
Martijn Riool
PKP.H.S. Kwakman
P.H.S. Kwakman
LBL. de Boer
L. de Boer
RCR.A. Cordfunke
R.A. Cordfunke
TMT.F. Moriarty
T.F. Moriarty