This paper presents a method for improving capability of a Hybrid Energy Storage System (HESS) comprised of a battery and supercapacitor (SC), for smoothing power fluctuations of renewable energy sources by adaptively controlling the state of charge (SOC) allocation range using automatic SOC management. The proposed method secures the preset SOC range of both battery and SC for power smoothing applications of renewables and also has the ability to significantly smooth power fluctuations using the virtual capacity concept of an energy storage system (ESS) by extending the SOC usage range. The bode plots of the proposed method are analyzed to observe the coverage of the power spectrum in the frequency domain in each storage based on the case studies. A criterion of HESS sizing, both battery and SC, is also developed based on the SOC range, smoothing time constant, and the power rating of renewables. The proposed method for the integration of HESS on renewable energy sources is verified with simulation results and characteristic analysis using PSCAD/EMTDC and MATLAB software.
The paper proposes a coordinated operation method of two independent storages for managing state-of-charge (SOC) and for providing ancillary service concerning frequency regulation (FR); furthermore, this article also introduces the power allocation scheme between two storages in consideration of the coverage of the frequency band for each storage along with the SOC management scheme of the supercapacitor and battery. We also provide a guideline for the storage sizing on the basis of the smoothing time constant. Additionally, we verify the advantage of the HESS in extending the lifetime of the battery, which is estimated by a real-time state-of-health (SOH) calculation method. The Bode plot of the proposed method is analyzed to observe the power spectrum coverage in the frequency domain through the case studies using PSCAD/EMTDC and MATLAB.
In this paper, a modified submodule (MSM) method is proposed to reduce capacitor voltage fluctuation by integrating a bidirectional buck‐boost type active power decoupling (APD) circuit into each SM for the low‐frequency operation of a converter system. The capacitor voltage fluctuation of the proposed MSM‐MMC can be significantly reduced compared to conventional SMs with the same capacitance by transferring the low‐frequency ripple power components to the auxiliary energy storage capacitor, resulting in a lower voltage fluctuation of the main capacitor in the SM, which requires a lower total SM capacitance. Additionally, a closed‐loop controller is proposed to control the APD capacitor voltages by inheriting the advantages of the repetitive controller and proportional‐integral (PI) controller to enhance the performance of SM capacitor voltage ripple suppression. The method can improve the start‐up performance of medium voltage drives without injecting high‐frequency components, which can avoid the common‐mode voltage imposed on the AC side of the system. The operating principle, auxiliary capacitor voltage control, and capacitor voltage ripple suppression control of the proposed MSM‐MMC method are analyzed in detail. The feasibility of the proposed method has been confirmed by simulation results based on case studies using MATLAB/SIMULINK software and further verified with hardware‐in‐the‐loop simulation (HILS) using the real‐time simulator OPAL‐RT platform.
This paper proposes an algorithm for determining the optimal capacitance by utilizing a mathematical model of a submodule (SM) capacitor in a modular multilevel converter (MMC) specifically for medium voltage motor drives (MVDs). By approximating the voltage fluctuation of the SM capacitor during low-frequency operation, it is feasible to ascertain the minimum capacitance required for the SM capacitor, ensuring that its voltage fluctuations remain within an acceptable limit that is predefined as a specified value. Moreover, the study considered the injection of both a high-frequency common-mode voltage (CMV) and a circulating current to alleviate the SM voltage fluctuation during the acceleration of motor drives. The effectiveness of the proposed method is validated through verification using time-domain simulation results obtained using the MATLAB/SIMULINK software and real-time simulation results acquired using the OPAL-RT simulator platform.
This paper presents a method of estimating the speed of an induction motor Luenberger. This method is based on speed sensorless estimation of vector controlled induction motor drive and adaptive control theory. A flux observer of an induction motor with a parameter adaptive scheme will be proposed. The parameters identified adaptively are stator and rotor resistance. A stability of the proposed adaptive flux observer will be proved by the Lyapunov's theorem. An adaptive scheme can be applied also to estimate motor speed without speed sensors. The theoretical basis of indirect field oriented vector control is explained in detail and it is implemented in Matlab, Simulink. Furthermore, experimental results of an indirect field-oriented induction motor control without speed sensor using DSP 1104 card are presented. Simulation and experimental results are presented to verify the principles and demonstrate the practicality of the approach. Those results are obtained under the condition that the motor parameters used in the observer are correct.
Wind-power ramp smoothing with hybrid energy storage must reduce grid-side excursions without assuming unlimited storage headroom or hiding battery-supercapacitor cycling stress. This paper proposes a constraint-aware hierarchical HESS controller (CA-HESS) for grid-code-oriented wind-power smoothing under ramp-rate, power, energy, state-of-charge (SOC), and efficiency limits. The method first forms an SOC-aware grid-power reference and aggregate HESS request, tightening the smoothing target when headroom is available and relaxing it near SOC boundaries. The requested HESS power is then separated into slow battery support and fast supercapacitor support, after which one-step feasible projection enforces converter-power and SOC/energy limits and records the residual as unserved HESS demand. The controller is evaluated on a 20 MW wind plant with a 5 MWh battery and a 0.5 MWh supercapacitor using a 365-day, 1-min wind profile and a one-day, 1-s profile; an SOC-feedback HESS benchmark based on adaptive SOC-range control is reproduced under identical ratings, limits, efficiencies, and metrics. Annually, CA-HESS reduces the P99 ramp from 0.635 to 0.379 MW/min and the violation rate from 0.0341\% to 0.0122\%. Its battery cycling is 30.7 EFC, compared with 435.8 EFC for fixed LPF-HESS and 502.8 EFC for the SOC-feedback HESS benchmark. In the 1-s test, the maximum 60-s power change decreases from 2.651 to 0.742 MW. These results indicate that CA-HESS provides a balanced smoothing--cycling--feasibility compromise, while ramp compliance remains conditional on feasible HESS headroom.