Sanja Kojic

Mrs. Sanja Kojic

University of Novi Sad Faculty of Technical Sciences
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Sanja KojicSanja Kojic
Sanja Kojic
Goran M. StojanovicGoran M. Stojanovic
Goran M. Stojanovic
VRVasa Radonic
Vasa Radonic
Microfluidics, one of the most attractive and fastest developed areas of modern science and technology, has found a number of applications in medicine, biology and chemistry. To address advanced designing challenges of the microfluidic devices, the research is mainly focused on development of efficient, low-cost and rapid fabrication technology with the wide range of applications. For the first time, this paper presents fabrication of microfluidic chips using hybrid fabrication technology—a grouping of the PVC (polyvinyl chloride) foils and the LTCC (Low Temperature Co-fired Ceramics) Ceram Tape using a combination of a cost-effective xurography technique and a laser micromachining process. Optical and dielectric properties were determined for the fabricated microfluidic chips. A mechanical characterization of the Ceram Tape, as a middle layer in its non-baked condition, has been performed and Young’s modulus and hardness were determined. The obtained results confirm a good potential of the proposed technology for rapid fabrication of low-cost microfluidic chips with high reliability and reproducibility. The conducted microfluidic tests demonstrated that presented microfluidic chips can resist 3000 times higher flow rates than the chips manufactured using standard xurography technique.

16 November 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
NDNuraina Anisa Dahlan
Nuraina Anisa Dahlan
ATAung Thiha
Aung Thiha
FIFatimah Ibrahim
Fatimah Ibrahim
LMLazar Milić
Lazar Milić
SMShalini Muniandy
Shalini Muniandy
Goran M. StojanovicGoran M. Stojanovic
Goran M. Stojanovic
BioNEMS/MEMS has emerged as an innovative technology for the miniaturisation of biomedical devices with high precision and rapid processing since its first R&D breakthrough in the 1980s. To date, several organic including food waste derived nanomaterials and inorganic nanomaterials (e.g., carbon nanotubes, graphene, silica, gold, and magnetic nanoparticles) have steered the development of high-throughput and sensitive bioNEMS/MEMS-based biosensors, actuator systems, drug delivery systems and implantable/wearable sensors with desirable biomedical properties. Turning food waste into valuable nanomaterials is potential groundbreaking research in this growing field of bioMEMS/NEMS. This review aspires to communicate recent progress in organic and inorganic nanomaterials based bioNEMS/MEMS for biomedical applications, comprehensively discussing nanomaterials criteria and their prospects as ideal tools for biomedical devices. We discuss clinical applications for diagnostic, monitoring, and therapeutic applications as well as the technological potential for cell manipulation (i.e., sorting, separation, and patterning technology). In addition, current in vitro and in vivo assessments of promising nanomaterials-based biomedical devices will be discussed in this review. Finally, this review also looked at the most recent state-of-the-art knowledge on Internet of Things (IoT) applications such as nanosensors, nanoantennas, nanoprocessors, and nanobattery.

29 July 2020 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
Susbin Raj WagleSusbin Raj Wagle
Susbin Raj Wagle
BKBozica Kovacevic
Bozica Kovacevic
DWDaniel Walker
Daniel Walker
CICorina Mihaela Ionescu
Corina Mihaela Ionescu
MJMelissa Jones
Melissa Jones
Hani Al-SalamiHani Al-Salami
Hani Al-Salami
Bile acids have recently been studied for potential applications as formulation excipients and enhancers for drug release; however, some bile acids are not suitable for this application. Unconjugated lithocholic acid (ULCA) has recently shown drug formulation-stabilizing and anti-inflammatory effects. Lipophilic drugs have poor gut absorption after an oral dose, which necessitates the administration of high doses and causes subsequent side effects. Probucol (PB) is a highly lipophilic drug with poor oral absorption that resulted in restrictions on its clinical prescribing. Hence, this study aimed to design new delivery systems for PB using ULCA-based matrices and to test drug formulation, release, temperature, and biological effects. ULCA-based matrices were formulated for PB oral delivery by applying the jet-flow microencapsulation technique using sodium alginate as a polymer. ULCA addition to new PB matrices improved the microcapsule’s stability, drug release in vitro (formulation study), and showed a promising effect in ex vivo study (p < 0.05), suggesting that ULCA can optimize the oral delivery of PB and support its potential application in diabetes treatment.

21 February 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
IKIvana Kundacina
Ivana Kundacina
MDMiroslav Djocos
Miroslav Djocos
MVMarija Vejin
Marija Vejin
SBSlobodan Birgermajer
Slobodan Birgermajer
ZPZoran Pavlovic
Zoran Pavlovic
VRVasa Radonic
Vasa Radonic
The connection of macrosystems with microsystems for in-line measurements is important in different biotechnological processes as it enables precise and accurate monitoring of process parameters at a small scale, which can provide valuable insights into the process, and ultimately lead to improved process control and optimization. Additionally, it allows continuous monitoring without the need for manual sampling and analysis, leading to more efficient and cost-effective production. In this paper, a 3D printed microfluidic (MF) chip for glucose (Glc) sensing in a liquid analyte is proposed. The chip made in Poly(methyl methacrylate) (PMMA) contains integrated serpentine-based micromixers realized via stereolithography with a slot for USB-like integration of commercial DropSens electrodes. After adjusting the sample’s pH in the first micromixer, small volumes of the sample and enzyme are mixed in the second micromixer and lead to a sensing chamber where the Glc concentration is measured via chronoamperometry. The sensing potential was examined for Glc concentrations in acetate buffer in the range of 0.1–100 mg/mL and afterward tested for Glc sensing in a cell culturing medium. The proposed chip showed great potential for connection with macrosystems, such as bioreactors, for direct in-line monitoring of a quality parameter in a liquid sample.

3 August 2020 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
Sanja KojicSanja Kojic
Sanja Kojic
SBSlobodan Birgermajer
Slobodan Birgermajer
VRVasa Radonić
Vasa Radonić
IKIvana Kundacina
Ivana Kundacina
JJJovana Jevremov
Jovana Jevremov
Goran M. StojanovicGoran M. Stojanovic
Goran M. Stojanovic

28 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
SQSaima Qureshi
Saima Qureshi
LMLazar Milić
Lazar Milić
Bojan PetrovicBojan Petrovic
Bojan Petrovic
MVMarija Vejin
Marija Vejin
Sanja KojicSanja Kojic
Sanja Kojic
Goran M. StojanovicGoran M. Stojanovic
Goran M. Stojanovic
The aim of this study was to tackle the topic of appropriate recommendations for artificial-saliva and mouthwash usage. The contact angle, pH, and conductivity of two artificial saliva solutions, four mouthwashes, and their mixtures on enamel, glass-ionomer, and composite dental materials were measured. The measurements were conducted with a MATLAB algorithm to minimize human error. The obtained values for the contact angle were in the range from 7.98° to 52.6°, and they showed completely nonlinear and nonuniform behavior for all investigated liquids and on all investigated substrates. Results reveal statistically significant differences among all tested liquids on all investigated substrates (p < 0.05). pH values ranged from 1.54 to 7.01. A wide range of conductivity values were observed, from 1205µS/cm in the saliva-stimulating solution to 6679 mS/cm in the artificial saliva. Spearman’s test showed a moderate positive correlation between the pH and conductivity of the tested fluids (R = 0.7108). A comparison of the data obtained using Image J software and the MATLAB algorithm showed consistency, not exceeding 5% error. When an experiment uses human material and bioactive materials THAT are used in biomedicine as substrates, an additional definition of protocols is highly recommended for future research on this topic.