Gerardo Pellegrino

Dr. Gerardo Pellegrino

University of Bologna
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2019 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
Gerardo PellegrinoGerardo Pellegrino
Gerardo Pellegrino
Carlo  ManganoCarlo Mangano
Carlo Mangano
RMRoberto Mangano
Roberto Mangano
AFAgnese Ferri
Agnese Ferri
VTValerio Taraschi
Valerio Taraschi
CMClaudio Marchetti
Claudio Marchetti
Despite the limited number of articles dedicated to its use, augmented reality (AR) is an emerging technology that has shown to have increasing applications in multiple different medical sectors. These include, but are not limited to, the Maxillo-facial and Dentistry disciplines of medicine. In these medical specialties, the focus of AR technology is to achieve a more visible surgical field during an operation. Currently, this goal is brought about by an accurate display of either static or dynamic diagnostic images via the use of a visor or specific glasses. The objective of this study is to evaluate the feasibility of using a virtual display for dynamic navigation via AR. The secondary outcome is to evaluate if the use of this technology could affect the accuracy of dynamic navigation. Two patients, both needing implant rehabilitation in the upper premolar area, were treated with flapless surgery. Prior to the procedure itself, the position of the implant was virtually planned and placed for each of the patients using their previous scans. This placement preparation contributed to a dynamic navigation system that was displayed on AR glasses. This, in turn, allowed for the use of a computer-aided/image-guided procedure to occur. Dedicated software for surface superimposition was then used to match the planned position of the implant and the real one obtained from the postoperative scan. Accuracies, using this procedure were evaluated by way of measuring the deviation between real and planned positions of the implants. For both surgeries it was possible to proceed using the AR technology as planned. The deviations for the first implant were 0.53 mm at the entry point and 0.50 mm at the apical point and for the second implant were 0.46 mm at the entry point and 0.48 mm at the apical point. The angular deviations were respectively 3.05° and 2.19°. From the results of this pilot study, it seems that AR can be useful in dental implantology for displaying dynamic navigation systems. While this technology did not seem to noticeably affect the accuracy of the procedure, specific software applications should further optimize the results.

9 November 2009 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
PFPietro Felice
Pietro Felice
CMClaudio Marchetti
Claudio Marchetti
GIGiovanna Iezzi
Giovanna Iezzi
APAdriano Piattelli
Adriano Piattelli
HWHelen Worthington
Helen Worthington
MEMarco Esposito
Marco Esposito

1 October 2009 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PFPietro Felice
Pietro Felice
RPRoberto Pistilli
Roberto Pistilli
GLGiuseppe Lizio
Giuseppe Lizio
Gerardo PellegrinoGerardo Pellegrino
Gerardo Pellegrino
ANAlessandro Nisii
Alessandro Nisii
CMClaudio Marchetti
Claudio Marchetti

10 November 2010 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
PFPietro Felice
Pietro Felice
Gerardo PellegrinoGerardo Pellegrino
Gerardo Pellegrino
LCLuigi Checchi
Luigi Checchi
RPRoberto Pistilli
Roberto Pistilli
MEMarco Esposito
Marco Esposito

Gerardo PellegrinoGerardo Pellegrino
Gerardo Pellegrino
Pierantonio BelliniPierantonio Bellini
Pierantonio Bellini
PCPier Francesco Cavallini
Pier Francesco Cavallini
AFAgnese Ferri
Agnese Ferri
AZAndrea Zacchino
Andrea Zacchino
Ugo ConsoloUgo Consolo
Ugo Consolo
Aim: the aim of this in vitro study was to test whether the implant placement accuracy and the operating time can be influenced by the operator’s experience. Materials and methods: sixteen models underwent a (Cone Beam Computer Tomography) CBCT and implant positioning was digitally planned on this. The models were randomly assigned to four operators with different levels of surgical experience. One hundred and twelve implant sites were drilled using a dynamic navigation system and operating times were measured. Based on postoperative CBCTs, dental implants were virtually inserted and superimposed over the planned ones. Two-dimensional and 3D deviations between planned and virtually inserted implants were measured at the entry point and at the apical point. Angular and vertical errors were also calculated. Results: considering coronal and apical 3D deviations, no statistically significant differences were found between the four operators (p = 0.27; p = 0.06). Some vectorial components of the deviation at the apical point and the angular errors of some operators differed from each other. Conclusions: within the limitations of this study, dynamic navigation can be considered a reliable technique both for experienced and novice clinicians.

FAFrancesca De Angelis
Francesca De Angelis
NPNicola Pranno
Nicola Pranno
ALESSIO FRANCHINAALESSIO FRANCHINA
ALESSIO FRANCHINA
Stefano Di CarloStefano Di Carlo
Stefano Di Carlo
Edoardo BraunerEdoardo Brauner
Edoardo Brauner
Luigi Vito StefanelliLuigi Vito Stefanelli
Luigi Vito Stefanelli
Background: Artificial intelligence (AI) has taken hold in public health because more and more people are looking to make a diagnosis using technology that allows them to work faster and more accurately, reducing costs and the number of medical errors. Methods: In the present study, 120 panoramic X-rays (OPGs) were randomly selected from the Department of Oral and Maxillofacial Sciences of Sapienza University of Rome, Italy. The OPGs were acquired and analyzed using Apox, which takes a panoramic X-rayand automatically returns the dental formula, the presence of dental implants, prosthetic crowns, fillings and root remnants. A descriptive analysis was performed presenting the categorical variables as absolute and relative frequencies. Results: In total, the number of true positive (TP) values was 2.195 (19.06%); true negative (TN), 8.908 (77.34%); false positive (FP), 132 (1.15%); and false negative (FN), 283 (2.46%). The overall sensitivity was 0.89, while the overall specificity was 0.98. Conclusions: The present study shows the latest achievements in dentistry, analyzing the application and credibility of a new diagnostic method to improve the work of dentists and the patients’ care.