Alberto Yúfera

Dr. Alberto Yúfera

Instituto de Microelectrónica de Sevilla (IMSE-CNM), Universidad de Sevilla
orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2005 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Open access
Alberto YúferaAlberto Yúfera
Alberto Yúfera
ARA. Rueda
A. Rueda
JMJ.M. Munoz
J.M. Munoz
RDR. Doldan
R. Doldan
GLG. Leger
G. Leger
ERE.O. Rodriguez-Villegas
E.O. Rodriguez-Villegas
In this paper, the design of a specific integrated circuit for the measurement of tissue impedances is presented. The circuit will be part of a multi-micro-sensor system intended to be used in cardiac surgery for sensing biomedical parameters in living bodies. Myocardium tissue impedance is one of these parameters which allows ischemia detection. The designed chip will be used in a four-electrode based setup where the effect of electrode interfaces are cancelled by design. The chip includes a circuit to generate the stimulus signals (sinusoidal current) and the circuitry to measure the magnitude and phase of the tissue impedance. Several integrated circuits have been designed, fabricated and tested, in a 0.8-/spl mu/m CMOS process, working at 3 V of power supply. Some of them including building blocks, and other with the whole measurement system. Experimental tests have shown the circuit feasibility giving expected results for both in-vitro and in-vivo test conditions.

2 June 2006 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Laura M. LechugaLaura M. Lechuga
Laura M. Lechuga
Javier TamayoJavier Tamayo
Javier Tamayo
Mar AlvarezMar Alvarez
Mar Alvarez
LCL.G. Carrascosa
L.G. Carrascosa
Alberto YúferaAlberto Yúfera
Alberto Yúfera
ABA. Bernad
A. Bernad

1 January 2013 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
PNPAULA DAZA NAVARRO
PAULA DAZA NAVARRO
AOAlberto Olmo
Alberto Olmo
DCDaniel Cañete
Daniel Cañete
Alberto YúferaAlberto Yúfera
Alberto Yúfera

11 June 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PGPablo Pérez García
Pablo Pérez García
GHGloria Huertas
Gloria Huertas
AMAndrés Maldonado-Jacobi
Andrés Maldonado-Jacobi
MMMaria E. Martin
Maria E. Martin
JVJuan Alfonso Serrano Viseas
Juan Alfonso Serrano Viseas
Alberto YúferaAlberto Yúfera
Alberto Yúfera
An alternative approach for cell-culture end-point protocols is proposed herein. This new technique is suitable for real-time remote sensing. It is based on Electrical Cell-substrate Impedance Spectroscopy (ECIS) and employs the Oscillation-Based Test (OBT) method. Simple and straightforward circuit blocks form the basis of the proposed measurement system. Oscillation parameters – frequency and amplitude – constitute the outcome, directly correlated with the culture status. A user can remotely track the evolution of cell cultures in real time over the complete experiment through a web tool continuously displaying the acquired data. Experiments carried out with commercial electrodes and a well-established cell line (AA8) are described, obtaining the cell number in real time from growth assays. The electrodes have been electrically characterized along the design flow in order to predict the system performance and the sensitivity curves. Curves for 1-week cell growth are reported. The obtained experimental results validate the proposed OBT for cell-culture characterization. Furthermore, the proposed electrode model provides a good approximation for the cell number and the time evolution of the studied cultures.

13 October 2022 in Journal of Biological Engineering
Verified
Journal Article
Open access
PDF file
DMDaniel Martín
Daniel Martín
JBJ. Bocio-Nuñez
J. Bocio-Nuñez
SSSantiago F. Scagliusi
Santiago F. Scagliusi
PPPablo Pérez
Pablo Pérez
GHGloria Huertas
Gloria Huertas
PDPaula Daza
Paula Daza
Background: Electrical stimulation is a novel tool to promote the differentiation and proliferation of precursor cells. In this work we have studied the effects of direct current (DC) electrical stimulation on neuroblastoma (N2a) and osteoblast (MC3T3) cell lines as a model for nervous and bone tissue regeneration, respectively. We have developed the electronics and encapsulation of a proposed stimulation system and designed a setup and protocol to stimulate cell cultures. Methods: Cell cultures were subjected to several assays to assess the effects of electrical stimulation on them. N2a cells were analyzed using microscope images and an inmunofluorescence assay, differentiated cells were counted and neurites were measured. MC3T3 cells were subjected to an AlamarBlue assay for viability, ALP activity was measured, and a real time PCR was carried out. Results: Our results show that electrically stimulated cells had more tendency to differentiate in both cell lines when compared to non-stimulated cultures, paired with a promotion of neurite growth and polarization in N2a cells and an increase in proliferation in MC3T3 cell line. Conclusions: These results prove the effectiveness of electrical stimulation as a tool for tissue engineering and regenerative medicine, both for neural and bone injuries. Bone progenitor cells submitted to electrical stimulation have a higher tendency to differentiate and proliferate, filling the gaps present in injuries. On the other hand, neuronal progenitor cells differentiate, and their neurites can be polarized to follow the electric field applied.

21 January 2004 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
ERE. Rodriguez-Villegas
E. Rodriguez-Villegas
Alberto YúferaAlberto Yúfera
Alberto Yúfera
ARA. Rueda
A. Rueda
This paper describes the implementation of a low-power floating-gate MOS (FGMOS)-based log-domain integrator that reduces the minimum required voltage supply and the risk of instabilities. The performance of the block is illustrated with the experimental results of a second-order low-pass/bandpass filter working in the audio range with a 1-V voltage supply and a maximum power consumption of 2 /spl mu/W. The experimental results show that the FGMOS transistor is a powerful device that enables the design of low-voltage-supply low-power-consumption filters which have very simple topologies.