Pavel Hyšpler

Dr. Pavel Hyšpler

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ANAdam Nocar
Adam Nocar
Ales ProchazkaAles Prochazka
Ales Prochazka
MKMagdaléna Kloubcová
Magdaléna Kloubcová
PHPavel Hyšpler
Pavel Hyšpler
MSMartin Schätz
Martin Schätz
TDTatjana Dostalova
Tatjana Dostalova
The integration of computational intelligence and augmented reality has become increasingly prevalent in dental practices. Three-dimensional (3D) printing techniques have now become routine in orthodontics, prosthetics, and maxillofacial surgery. The objective of this study is to assess the effectiveness of stereolithography (SLA) printed models compared to traditional plaster casts over a three-year period. The experimental dataset consisted of 36 orthodontic patients, each with SLA printed models and plaster casts for both the upper and lower jaws, resulting in a total of 72 scans in the form of Standard Template Library (STL) files and 72 traditional impressions. The upper dental arch models were constructed using an SLA 3D printer, employing a blue 405 nm laser beam to solidify a liquid polymer. The classical plaster casts were prepared in a dental laboratory. The models were retained for long-term orthodontic therapy control. To evaluate the differences between the dental models, a laboratory scanner was used to generate virtual casts. The meshes obtained were adjusted and pre-aligned using the best-fit algorithm. Subsequently, registration of the models was performed using the iterative closest point (ICP) algorithm. Distances between the point clouds and meshes for each point of the printed model were calculated by determining the nearest triangle on the reference mesh (cast). Additionally, the model surfaces were assessed using a scanning electron microscope and a stereomicroscope. The results from 22 experimental datasets indicated a high level of agreement between the plaster casts and virtual surfaces, with a mean absolute difference of 0.018 mm and a standard deviation of 0.17 mm. These values were obtained by averaging 231,178 data points for each comparison. Overall, this study demonstrates the comparability and accuracy of SLA printed models in relation to traditional plaster casts, supporting their potential as reliable alternatives in dental practice.

30 September 2024 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
PHPavel Hyšpler
Pavel Hyšpler
PUPetra Urbanová
Petra Urbanová
TDTatjana Dostalova
Tatjana Dostalova

22 July 2023 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
PHPavel Hyšpler
Pavel Hyšpler
JSJakub Strnad
Jakub Strnad
RSRadim Sala
Radim Sala
TDTatjana Dostalova
Tatjana Dostalova

6 July 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
PHPavel Hyšpler
Pavel Hyšpler
JBJiří Borovec
Jiří Borovec
TDTatjana Dostalova
Tatjana Dostalova
This article introduces a modified reverse scan technique for abutment teeth that incorporates laboratory scanners into a fully digital workflow to enhance accuracy and reduces the impact of stitching and merging errors associated with long-span intraoral scans when fabricating extensive tooth-supported prostheses. This cost-effective, time-saving, and versatile procedure uses a 3D-printed interim tooth-supported prosthesis that is sectioned, bonded intraorally, and scanned with a laboratory scanner to improve the virtual definitive cast. The modification is performed using free software.

10 March 2025 in Česká stomatologie a praktické zubní lékařství
Verified
Journal Article
Open access
PDF file
PHPavel Hyšpler
Pavel Hyšpler
TDT Dostálová
T Dostálová
?vod a c?l: Pln? digit?ln? workflow za??n? ovl?dat na?e ordinace. P?esnost a spr?vnost n?kter?ch intraor?ln?ch skener? je nejenom dostate?n?, ale v?razn? p?ekon?v? klasickou technologii otiskov?n? (s?drov? model) pro ??ely mal?ch protetick?ch ... ?vod a c?l: Pln? digit?ln? workflow za??n? ovl?dat na?e ordinace. P?esnost a spr?vnost n?kter?ch intraor?ln?ch skener? je nejenom dostate?n?, ale v?razn? p?ekon?v? klasickou technologii otiskov?n? (s?drov? model) pro ??ely mal?ch protetick?ch ...

5 May 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HEHana Eliášová
Hana Eliášová
TDTatjana Dostalova
Tatjana Dostalova
PHPavel Hyšpler
Pavel Hyšpler
ANAdam Nocar
Adam Nocar
The increasing demand for better dental aesthetics has driven the development of tooth-whitening techniques that are effective while reducing invasiveness. Hydrogen peroxide (HP) and carbamide peroxide (CP) continue to be the most common active ingredients in bleaching products. Various types of light and laser activation have been introduced to speed up the bleaching process and decrease clinical application time. However, published results regarding their effectiveness and biological safety are inconsistent and sometimes contradictory. Aim: The objective of this study was to identify irradiation conditions that optimise the whitening performance of peroxide-based bleaching agents while ensuring safety for dental hard tissues and ocular structures. This objective was achieved through a systematic synthesis and meta-analyses of both experimental and clinical evidence on bleaching techniques, light or laser activation, and related treatment outcomes. Additionally, the study aimed to provide an integrated overview of currently used irradiation technologies, bleaching agents, treatment protocols, and relevant safety considerations. Methods: A multi-stage analytical approach was employed. Evidence was collected from systematic reviews, randomised and non-randomised clinical trials, and laboratory-based in vitro investigations. The studies assessed differences in bleaching agents (HP and CP), their concentrations, and application protocols, as well as various activation systems, including halogen lamps, conventional LEDs, violet LEDs, metal–halide lamps, and laser wavelengths such as visible blue (~440 nm), red or near-infrared (~1.7 µm), and other spectral ranges. Extracted outcome measures included tooth colour improvement (ΔSGU, ΔE), incidence of tooth sensitivity, changes in enamel surface morphology, temperature increases in the pulp chamber, and the bond strength of restorative or orthodontic materials. When methodological compatibility permitted, quantitative synthesis and meta-analysis were conducted to estimate the effects of activation modalities and irradiation parameters. Results: Analysis of data from 28 systematic reviews and numerous clinical and laboratory studies showed that the degree of colour improvement did not consistently rely on peroxide concentration or on whether bleaching was performed in-office or through home-based protocols. In most studies, adding light activation did not produce a clearly superior whitening effect compared to chemically driven bleaching alone. However, certain laser-assisted methods—especially those using blue diode lasers around 440 nm or near-infrared diode lasers near 1.7 µm—were linked with faster whitening responses and, in several in vitro experiments, fewer enamel surface irregularities. Increases in pulp temperature remained below the generally accepted safety threshold of 5.5 °C in the reported experimental conditions. While laser activation reduced treatment time, some studies observed a temporary decrease in the bond strength of orthodontic brackets following bleaching. Photobiomodulation techniques seem promising for reducing post-treatment sensitivity, although more robust clinical evidence is still needed. Conclusions: Targeted activation with diode lasers, especially within the blue and near-infrared spectral ranges, may speed up the whitening process and potentially minimise structural changes to enamel when irradiation parameters are carefully managed. Despite these positive findings, current clinical evidence remains limited. Well-designed randomised controlled trials with standardised treatment protocols are essential to determine the best wavelengths, energy delivery settings, and safety limits for laser-assisted dental bleaching.