Ignazio Kurti

Dr. Ignazio Kurti

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MPMilena Pisano
Milena Pisano
Łukasz ZadrożnyŁukasz Zadrożny
Łukasz Zadrożny
AMAnna Di Marzio
Anna Di Marzio
Ignazio KurtiIgnazio Kurti
Ignazio Kurti
Silvio Mario MeloniSilvio Mario Meloni
Silvio Mario Meloni
Marco TallaricoMarco Tallarico
Marco Tallarico
The aim of the present in vitro comparative study is to validate a novel composite polymer, named “ONLY”, developed to overcome the mechanical drawbacks of conventional, metal-reinforced poly(methyl methacrylate) (PMMA) interim restoration. Ten interim restorations were designed and fabricated (five in the composite “ONLY” group, and five in the metal-reinforced PMMA group). All the samples were screwed into the prototype models, simulating a complete edentulous mandible rehabilitated with six straight implants. Outcome measures were break point (load, N) and displacement (mm) through a static compression test, and material behavior through a dynamic cyclic test method (fatigue test). A total of 20 samples were tested (10 for static and 10 for dynamic). In each group, five samples (test and control) were used. All the specimens completed the mechanical tests, as planned. There was no statistically significant difference between groups for any test. In the test group, the break point was 1953.19 ± 543.73 N, while it was 2031.10 ± 716.68 N in the control group (p = 0.775). The displacement was 1.89 ± 0.34 mm in the test group and 1.98 ± 0.75 mm in the control group (p = 0.763). Using the dynamic cyclic test method, in the control group the mean load was 2504.60 ± 972.15 N, while in the test group the mean load was 3382.00 ± 578.50 N. The difference between groups was 877.40 ± 579.30 N (p value = 0.121). Within the limitations of this in vitro study, the novel composite polymer can be used to immediately load dental implants. Further clinical research is needed to confirm these preliminary results.

15 August 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
MPMilena Pisano
Milena Pisano
Łukasz ZadrożnyŁukasz Zadrożny
Łukasz Zadrożny
AMAnna Di Marzio
Anna Di Marzio
Ignazio KurtiIgnazio Kurti
Ignazio Kurti
Silvio Mario MeloniSilvio Mario Meloni
Silvio Mario Meloni
Marco TallaricoMarco Tallarico
Marco Tallarico
Metal-reinforced polymethyl-methacrylate (PMMA) is considered the gold standard material for immediate loading on dental implants. However, mechanical problems under loading cycles can occur, such as fractures. To overcome these drawbacks, a novel polymer-based material has been proposed. The aim of the present in vitro comparative research is to validate a novel composite polymer developed to replace metal-reinforced PMMA interim restoration due to its advantages of good mechanical proprieties, easier manufacturing, and handling. Ten interim restorations were CAD/CAM designed and fabricated (five in the composite "ONLY" group, and five in the metal-reinforced PMMA group). All the samples were screwed into the prototype models, simulating a complete edentulous mandible rehabilitated with six straight implants. Outcome measures were breakpoint (load, N) and displacement (mm) thought a static, compression test and material behavior under dynamic cyclic test method (fatigue test). A total of twenty samples were tested. Ten samples were used for each test (10 for static and 10 for dynamic), five samples were used in each group (test and control). All the specimens completed the mechanical tests, as planned. There was no statistically significant difference between groups for all, breakpoint, displacement and fatigue tests. Breakpoint in the test group was 1953.19 ± 543.73 N, while, it was 2031.10 ± 716.68 N in the control group, with no statistically significant difference (P=0.775). The displacement was 1.89 ± 0.34 mm in the test group and 1.98 ± 0.75 mm in the control group, again, with no statistically significant difference (P=0.763). Under dynamic cyclic test method, in the control group the mean load was 2504.6 ± 972.15 N, while, in the test group the mean load was 3382 ± 578.5 N. The difference between group was 877.4 ± 579.3 N (p value=0.121). With the limitation of this in vitro study, the novel composite polymer can be used to immediately load dental implants. Further clinical researches are needed to confirm this preliminary results.