Igor Džolev

Prof. Dr. Igor Džolev

University of Novi Sad, Novi Sad, Serbia
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Safety Science
Verified
Journal Article
Closed access
Igor DžolevIgor Džolev
Igor Džolev
MLMirjana Laban
Mirjana Laban
SDSuzana Draganić
Suzana Draganić

26 July 2022 in Buildings
Verified
Journal Article
Open access
PDF file
VŽVladimir Živaljević
Vladimir Živaljević
ĐJĐorđe Jovanović
Đorđe Jovanović
DKDusan I. Kovacevic
Dusan I. Kovacevic
Igor DžolevIgor Džolev
Igor Džolev
The use of cold-formed steel (CFS) members in structural engineering has been on the increase recently due to a wide range of benefits. The placement of electrical and/or plumbing installations within the floor or wall thickness requires that members are being manufactured with holes along the web, inevitably affecting their resistance. This article aims at providing a useful and comprehensive overview of the existing literature regarding CFS members with web holes. Experimental and numerical research on CFS members with web holes subjected to pure compression, bending, web crippling and shear is outlined and discussed. Although research on these types of members date back to the early 1970s, the greatest progress in the research field of CFS members with web holes was achieved during the past 15 years; hence, mostly the research conducted during this period was addressed. Additionally, design proposals are summarised for each of the aforementioned stress states. A brief description of the main concepts of design presented in four principal design codes, as well as numerical solution methods for predicting global, local, and distortional buckling modes, is also presented, aiming to collect the accessible up-to-date knowledge of CFS members with holes and identify areas that were modestly covered by previous research.

3 July 2025 in Buildings
Verified
Journal Article
Open access
PDF file
Igor DžolevIgor Džolev
Igor Džolev
SKSofija Kekez-Baran
Sofija Kekez-Baran
ARAndrija Rašeta
Andrija Rašeta
The thermal conductivity of steel is high compared to other materials such as concrete or timber. Therefore, fire protection measures are applied to prolong the duration between the onset of fire exposure and the final loss of load-bearing function of a steel structure. The most common passive fire protection measure is the application of intumescent coating (IC), a thin film that expands at elevated temperatures and forms an insulating char layer of lower thermal conductivity. This paper focuses on structural steel beams with IPE open-section profiles protected by a water-based IC and subjected to static and standard fire loading. ANSYS 16.0 is used to simulate heat transfer, with thermal conductivity function described by standard multivariate linear regression analysis, followed by mechanical analysis considering degradation of material mechanical properties at elevated temperatures. Simulations are conducted for all IPE profile sizes, with varying initial degrees of utilisation, beam lengths, and coating thicknesses. Results indicated fire resistance times ranging from 24 to 53.5 min, demonstrating a relatively good level of fire resistance even with the minimal IC thickness. Furthermore, artificial neural networks were developed to predict the fire resistance time of steel members with IC using varying numbers of hidden neurons and subset ratios. The model achieved a predictability level of 99.9% upon evaluation.

1 January 2021 in Thermal Science
Verified
Journal Article
Open access
PDF file
MLMirjana Laban
Mirjana Laban
MCMeri J. Cvetkovska
Meri J. Cvetkovska
ATAna Gj. Trombeva-Gavriloska
Ana Gj. Trombeva-Gavriloska
SDSuzana R. Draganić
Suzana R. Draganić
MLMarijana T. Lazarevska
Marijana T. Lazarevska
Igor DžolevIgor Džolev
Igor Džolev
According to official fire statistics, chimney fires account for almost 20% of all fires that occur in family residential buildings every year in the Balkan region. The high temperature from the chimneys may have an influence on fire spreading to the wooden girders. The objective of the study was to gather and analyse data on timber structure fire incidents occurring in family residential buildings in lowland rural settlements in Serbia (2010-2014) and a mountain settlement in Montenegro (2007-2013) in order to determine the extent to which existing data can be used in fire risk assessment. Additionally, the chimney-timber floor heat transfer mechanism was investigated, namely, the time dependent temperature distribution in the cross-section of few types of mostly used chimneys and floor structures were analysed. This research illustrates how the lack of chimney maintenance and social vulnerability of the settlements (aged rural population with low incomes, living in many cases alone in old houses in areas with limited access to distance heating systems or piped gas) could influence the fire risk in timber structures in rural lowland and mountain areas. It is shown that significant differences exist with respect to fire causation over time and the type of wooden structural elements ? due to different temperature distribution in the cross-sections of the floor structure, both in lowland and mountain settlements.


1 January 2025
Verified
Conference Paper
Closed access
VPVladan Pantić
Vladan Pantić
Slobodan SupicSlobodan Supic
Slobodan Supic
Suzana DraganićSuzana Draganić
Suzana Draganić
Igor DžolevIgor Džolev
Igor Džolev
Sustainable development in the twenty-first century necessitates the strategic use of renewable, environmentally-friendly materials as well as inventive thinking. Hence, it is unavoidable to assess their performance and engineering properties to be accepted by the civil engineering community. Traditional masonry structures have relied heavily on conventional cement-lime mortars. Owing to enormous natural resources consumption (limestone and clay) and a large amount of CO2 discharged into the environment due to the thermal treatment of raw materials, these mortars might be classified as unfriendly in contemporary engineering practice. Therefore, in recent years, extensive research has been conducted on the application of various pozzolanic materials as a feasible option for developing new, alternative types of greener masonry mortars. However, just a few studies have addressed the fire behaviour aspect of masonry mortars, particularly those containing supplementary cementitious materials. This paper focuses on the reaction to fire of nine different masonry mortar mixtures incorporating locally accessible waste materials: ceramic waste powder, fly ash, and biomass ash, as cement substitutes. Non-combustibility and the gross heat of combustion tests were performed with the aim of categorizing investigated mortars into fire reaction classes. The results indicate that all mortar combinations meet the requirements for the A1 fire reaction class, while all blended mortars had lower mass loss and heat release in relation to the reference cement-lime mortars.