Muhammad Ihsan Mukrim

Mr. Muhammad Ihsan Mukrim

Institut Teknologi B.J. Habibie, Parepare, Sulawesi Selatan, Indonesia
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Civil Engineering Journal
Verified
Journal Article
Open access
PDF file
EBErniati Bachtiar
Erniati Bachtiar
MMMustaan Mustaan
Mustaan Mustaan
FJFaris Jumawan
Faris Jumawan
MAMeldawati Artayani
Meldawati Artayani
TTTahang Tahang
Tahang Tahang
Muhammad Ihsan MukrimMuhammad Ihsan Mukrim
Muhammad Ihsan Mukrim
This study aims to examine the effect of recycled Polyethylene Terephthalate (PET) artificial aggregate as a substitute for coarse aggregate on the compressive strength and flexural strength, and the volume weight of the concrete. PET plastic waste is recycled by heating to a boiling point of approximately 300°C. There are five variations of concrete mixtures, defined the percentage of PET artificial aggregate to the total coarse aggregate, by 0, 25, 50, 75 and 100%. Tests carried out on fresh concrete mixtures are slump, bleeding, and segregation tests. Compressive and flexural strength tests proceeded based on ASTM 39/C39M-99 and ASTM C293-79 standards at the age of 28 days. The results showed that the use of PET artificial aggregate could improve the workability of the concrete mixture. The effect of PET artificial aggregate as a substitute for coarse aggregate on the compressive and flexural strength of concrete is considered very significant. The higher the percentage of PET plastic artificial aggregate, the lower the compressive and flexural strength, and the volume weight, of the concrete. Substitution of 25, 50, 75 and 100% of PET artificial aggregate gave decreases in compressive strength of 30.06, 32.39, 41.73 and 44.06% of the compressive strength of the standard concrete (18.20 MPa), respectively. The reductions in flexural strength were by respectively 19.03, 54.50, 53.95 and 61.00% of the standard concrete's flexural strength (3.59 MPa). The reductions in volume weight of concrete were by respectively 8.45, 17.71, 25.07 and 34.60% of the weight of the standard concrete volume of 2335.4 kg/m3 Doi: 10.28991/cej-2020-03091626 Full Text: PDF

1 January 2019 in FME Transactions
Verified
Journal Article
Open access
PDF file
RTRustan Tarakka
Rustan Tarakka
NSNasaruddin Salam
Nasaruddin Salam
JJJ Jalaluddin
J Jalaluddin
Muhammad Ihsan MukrimMuhammad Ihsan Mukrim
Muhammad Ihsan Mukrim
This paper presents analyses of the effect of blowing flow control and variations on front geometry towards the reduction of aerodynamic drag on vehicle models. Blowing flow control is an alternative measure in modifying the onset of flow separation in the boundary layer on the surface of the vehicle. The modification is expected to reduce the dominating influence of the separation area on the total drag. Conducted in computational and experimental approaches, the research investigated the effect of frontal slant angle variations (θ) of 25°, 30° and 35° towards the reduction of aerodynamic drag on vehicle models on the application of blowing flow control with upstream and blowing speed of 16.7 m/s and 0.5 m/s, respectively. Load cells were used in the experimental method to validate the reduction of aerodynamic drag obtained from computational method. It is indicated that the effects of blowing flow control and variations on front geometry are significant in the increasing on pressure coefficients and the reduction of aerodynamic drag on vehicle models. The largest increase on pressure coefficients of 38.93% is indicated on the vehicle model with θ=35°, while the largest reduction of aerodynamic drag occurred on the same model with the values of 14.81 and 12.54 for computational and experimental methods, respectively.

1 August 2021 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
RTR Tarakka
R Tarakka
NSN Salam
N Salam
JAJalaluddin
Jalaluddin
WRW Rauf
W Rauf
Muhammad Ihsan MukrimMuhammad Ihsan Mukrim
Muhammad Ihsan Mukrim
The innovation in the automotive industry must prioritize the issue of energy security and the environment. One aspect of the innovations is regarding the development of more aerodynamic vehicle design. The study of vehicle aerodynamics has been considered as very important, due to its direct relation to the safety and efficiency factors of energy utilization. Applying active control on the onset region of flow separation is one example of the efforts. This study aims to analyse the effect of the application of active control by suction to the aerodynamic drag of the vehicle model through qualitatively observations of flow dynamics and quantitatively pressure fields. The test model is a modified Ahmed body with 35° slant angles and varied flow orientations. This study has been conducted in both numerical computation and experimental testing at a suction velocity of 1.0 m/s and upstream velocity of 11.1 m/s, 13.9 m/s, and 16.7 m/s, respectively. The results have found out that the attachment of active control is proven capable able to delay flow separations, to increase the pressure coefficients on the back wall, and to reduce aerodynamic drag by 10.8487% for computational methods and 10.9748% for experimental methods.


1 May 2020 in Universal Journal of Mechanical Engineering
Verified
Journal Article
Open access
PDF file
WRWawan Rauf
Wawan Rauf
RTRustan Tarakka
Rustan Tarakka
JJJalaluddin Jalaluddin
Jalaluddin Jalaluddin
Muhammad Ihsan MukrimMuhammad Ihsan Mukrim
Muhammad Ihsan Mukrim
Flow separation is expected to have the effect of increasing aerodynamic drag due to decreased pressure distribution at the rear of the vehicle. The faster the flow separation occurs, the lower the pressure distribution is in the area, thereby reducing vehicle performance. Therefore, flow modification is needed with expected effects on the separation delay and the reduction in wake and vortex formation. This modification can be done through the application of suction active control in the separation area. The research is intended to analyze the effect of suction active control on flow characteristics, pressure distribution and aerodynamic drag on vehicle models with suction velocity variations. The test model used is an Ahmed model modified by changing the orientation of the flow. The study used a numerical computational approach with a standard k-epsilon turbulence model at 19.4 m/s upstream velocity. Results revealed that the use of flow active control was able to reduce wake and vortex formation through separation delay and to increase the minimum pressure coefficient by 73% on the model with Usc2 suction velocity of 0.5 m/s, gaining the highest drag coefficient reduction of 10.897% in the same model.

1 January 2022
Verified
Journal Article
Open access
NSNasaruddin Salam
Nasaruddin Salam
RTRustan Tarakka
Rustan Tarakka
JAJalaluddin
Jalaluddin
DIDandhy Iriansyah
Dandhy Iriansyah
Muhammad Ihsan MukrimMuhammad Ihsan Mukrim
Muhammad Ihsan Mukrim