26 February 2021 in Respiratory Research
Verified
Journal Article
Open access
PDF file
FBFederico Bianco
Federico Bianco
FSFabrizio Salomone
Fabrizio Salomone
IMilaria milesi
ilaria milesi
XMXabier Murgia
Xabier Murgia
SBSauro Bonelli
Sauro Bonelli
JPJane Pillow
Jane Pillow
Delivery of medications to preterm neonates receiving non-invasive ventilation (NIV) represents one of the most challenging scenarios for aerosol medicine. This challenge is highlighted by the undersized anatomy and the complex (patho)physiological characteristics of the lungs in such infants. Key physiological restraints include low lung volumes, low compliance, and irregular respiratory rates, which significantly reduce lung deposition. Such factors are inherent to premature birth and thus can be regarded to as theintrinsic factorsthat affect lung deposition. However, there are a number ofextrinsic factorsthat also impact lung deposition: such factors include the choice of aerosol generator and its configuration within the ventilation circuit, the drug formulation, the aerosol particle size distribution, the choice of NIV type, and the patient interface between the delivery system and the patient. Together, these extrinsic factors provide an opportunity to optimize the lung deposition of therapeutic aerosols and, ultimately, the efficacy of the therapy.In this review, we first provide a comprehensive characterization of both the intrinsic and extrinsic factors affecting lung deposition in premature infants, followed by a revision of the clinical attempts to deliver therapeutic aerosols to premature neonates during NIV, which are almost exclusively related to the non-invasive delivery of surfactant aerosols. In this review, we provide clues to the interpretation of existing experimental and clinical data on neonatal aerosol delivery and we also describe a frame of measurable variables and available tools, including in vitro and in vivo models, that should be considered when developing a drug for inhalation in this important but under-served patient population.

12 March 2020 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
FBFederico Bianco
Federico Bianco
EPElena Pasini
Elena Pasini
MNMarcello Nutini
Marcello Nutini
XMXabier Murgia
Xabier Murgia
CSCarolin Stoeckl
Carolin Stoeckl
ABAlbert Bucholski
Albert Bucholski
Non-invasive delivery of nebulized surfactant has been a long-pursued goal in neonatology. Our aim was to evaluate the performance of an investigational vibrating-membrane nebulizer in a realistic non-invasive neonatal ventilation circuit with different configurations. Surfactant (aerosols were generated with a nebulizer in a set-up composed of a continuous positive airway pressure (CPAP) generator with a humidifier, a cast of the upper airway of a preterm infant (PrINT), and a breath simulator with a neonatal breathing pattern. The lung dose (LD), defined as the amount of surfactant collected in a filter placed at the distal end of the PrINT cast, was determined after placing the nebulizer at different locations of the circuit and using either infant nasal mask or nasal prongs as CPAP interfaces. The LD after delivering a range of nominal surfactant doses (100–600 mg/kg) was also investigated. Surfactant aerosol particle size distribution was determined by laser diffraction. Irrespective of the CPAP interface used, about 14% of the nominal dose (200 mg/kg) reached the LD filter. However, placing the nebulizer between the Y-piece and the CPAP interface significantly increased the LD compared with placing it 7 cm before the Y-piece, in the inspiratory limb. (14% ± 2.8 vs. 2.3% ± 0.8, nominal dose of 200 mg/kg). The customized eFlow Neos showed a constant aerosol generation rate and a mass median diameter of 2.7 μm after delivering high surfactant doses (600 mg/kg). The customized eFlow Neos nebulizer showed a constant performance even after nebulizing high doses of undiluted surfactant. Placing the nebulizer between the Y-piece and the CPAP interface achieves the highest LD under non-invasive ventilation conditions.

2 April 2020 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
FBFederico Bianco
Federico Bianco
EPElena Pasini
Elena Pasini
MNMarcello Nutini
Marcello Nutini
XMXabier Murgia
Xabier Murgia
CSCarolin Stoeckl
Carolin Stoeckl
ABAlbert Bucholski
Albert Bucholski
The delivery of nebulized medications to preterm infants during Non-Invasive Ventilation (NIV) remains an unmet clinical need. In this regard, the effective delivery of nebulized surfactant has been particularly investigated in preclinical and clinical studies. In this work, we investigated the feasibility of delivering nebulized surfactant through various commercially available nasal prong types. We first performed a compendial characterization of surfactant aerosols generated by the eFlow Neos nebulizer, customized to be used in neonates, determining the amount of surfactant delivered by the device as well as the aerodynamic characteristics of surfactant aerosols. Additionally, we extended the compendial characterization by testing the effect of different nasal prong types on the estimated lung dose using a realistic Continuous Positive Airway Pressure (CPAP) circuit that included a cast of the upper airways of a preterm neonate. The compendial characterization of surfactant aerosols delivered through different nasal prongs achieved relatively high delivered surfactant doses (in the range 63–74% of the nominal dose), with aerodynamic characteristics displaying mass median aerodynamic diameters ranging between 2.52 and 2.81 µm. Nevertheless, when using a representative in vitro setup mimicking NIV in a clinical setting, significant differences were observed in terms of the estimated lung dose accounting for up to two-fold differences (from 10% to 20% estimated lung deposition of the nominal dose) depending on the chosen nasal prong type. Considering that surfactant lung deposition rates are correlated with therapeutic efficacy, this study points out the relevance of choosing the appropriate NIV interface to maximize the lung dose of nebulized medications.

20 May 2022 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
FRFrancesca Ricci
Francesca Ricci
AMArianna Mersanne
Arianna Mersanne
MSMatteo Storti
Matteo Storti
MNMarcello Nutini
Marcello Nutini
GPGiulia Pellicelli
Giulia Pellicelli
FSFabrizio Salomone
Fabrizio Salomone
High-flow nasal cannula (HFNC) is a non-invasive respiratory support (NRS) modality to treat premature infants with respiratory distress syndrome (RDS). The delivery of nebulized surfactant during NRS would represent a truly non-invasive method of surfactant administration and could reduce NRS failure rates. However, the delivery efficiency of nebulized surfactant during HFNC has not been evaluated in vitro or in animal models of respiratory distress. We, therefore, performed first a benchmark study to compare the surfactant lung dose delivered by commercially available neonatal nasal cannulas (NCs) and HFNC circuits commonly used in neonatal intensive care units. Then, the pulmonary effect of nebulized surfactant delivered via HFNC was investigated in spontaneously breathing rabbits with induced respiratory distress. The benchmark study revealed the surfactant lung dose to be relatively low for both types of NCs tested (Westmed NCs 0.5 ± 0.45%; Fisher & Paykel NCs 1.8 ± 1.9% of a nominal dose of 200 mg/kg of Poractant alfa). The modest lung doses achieved in the benchmark study are compatible with the lack of the effect of nebulized surfactant in vivo (400 mg/kg), where arterial oxygenation and lung mechanics did not improve and were significantly worse than the intratracheal instillation of surfactant. The results from the present study indicate a relatively low lung surfactant dose and negligible effect on pulmonary function in terms of arterial oxygenation and lung mechanics. This negligible effect can, for the greater part, be explained by the high impaction of aerosol particles in the ventilation circuit and upper airways due to the high air flows used during HFNC.

30 September 2020 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
FTFrancesco Tarantini
Francesco Tarantini
IMilaria milesi
ilaria milesi
XMXabier Murgia
Xabier Murgia
FBFederico Bianco
Federico Bianco
Raffaele L. Dellaca'Raffaele L. Dellaca'
Raffaele L. Dellaca'
Nebulization could be a valuable solution to administer drugs to neonates receiving noninvasive respiratory support. Small and irregular tidal volumes and air leaks at the patient interface, which are specific characteristics of this patient population and are primarily responsible for the low doses delivered to the lung (DDL) found in this application, have not been thoroughly addressed in in vitro and in vivo studies for quantifying DDL. Therefore, we propose a compartment-based mathematical model able to describe convective aerosol transport mechanisms to complement the existing deposition models. Our model encompasses a mechanical ventilator, a nebulizer, and the patient; the model considers the gas flowing between compartments, including air leaks at the patient–ventilator interface. Aerosol particles are suspended in the gas flow and homogeneously distributed. The impact of breathing pattern variability, volume of the nebulizer, and leaks level on DDL is assessed in representative conditions. The main finding of this study is that convective mechanisms associated to air leaks and breathing patterns with tidal volumes smaller than the nebulizer dramatically reduce the DDL (up to 70%). This study provides a possible explanation to the inconsistent results of drug aerosolization in clinical studies and may provide guidance to improve nebulizer design and clinical procedures.