Irene Gennarelli

Dr. Irene Gennarelli

Italian Institute of Technology, Genoa, Liguria, Italy
+2
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2024 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
GDGiorgio Davico
Giorgio Davico
LLLuciana Labanca
Luciana Labanca
IGIrene Gennarelli
Irene Gennarelli
MBMaria Grazia Benedetti
Maria Grazia Benedetti
MVMarco Viceconti
Marco Viceconti
The aging process is commonly accompanied by a general or specific loss of muscle mass, force and/or function that inevitably impact on a person’s quality of life. To date, various clinical tests and assessments are routinely performed to evaluate the biomechanical status of an individual, to support and inform the clinical management and decision-making process (e.g., to design a tailored rehabilitation program). However, these assessments (e.g., gait analysis or strength measures on a dynamometer) are typically conducted independently from one another or at different time points, providing clinicians with valuable yet fragmented information. We hereby describe a comprehensive protocol that combines both in vivo measurements (maximal voluntary isometric contraction test, superimposed neuromuscular electrical stimulation, electromyography, gait analysis, magnetic resonance imaging, and clinical measures) and in silico methods (musculoskeletal modeling and simulations) to enable the full characterization of an individual from the biomechanical standpoint. The protocol, which requires approximately 4 h and 30 min to be completed in all its parts, was tested on twenty healthy young participants and five elderlies, as a proof of concept. The implemented data processing and elaboration procedures allowing for the extraction of several biomechanical parameters (including muscle volumes and cross-sectional areas, muscle activation and co-contraction levels) are thoroughly described to enable replication. The main parameters extracted are reported as mean and standard deviation across the two populations, to highlight the potential of the proposed approach and show some preliminary findings (which were in agreement with previous literature).

6 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
IGIrene Gennarelli
Irene Gennarelli
TVTiwana VARRECCHIA
Tiwana VARRECCHIA
GCGiorgia Chini
Giorgia Chini
NMNiki Martinel
Niki Martinel
Micheloni christianMicheloni christian
Micheloni christian
ARAlberto Ranavolo
Alberto Ranavolo
Manual material handling is one of the leading causes of work-related low-back disorders, and an accurate assessment of the biomechanical risk is essential to support prevention strategies. Despite workers’ interest in wearable sensor networks for quantifying exposure metrics, these systems still present several limitations, including potential interference with natural movements and workplaces, and concerns about durability and cost-effectiveness. For these reasons, alternative motion capture methods are being explored. Among them, completely markerless (ML) technologies are being increasingly applied in ergonomics. This study aimed to compare a wearable sensor network and an ML system in the evaluation of lifting tasks, focusing on the variables and multipliers used to compute the recommended weight limit (RWL) and the lifting index (LI) according to the revised NIOSH lifting equation. We hypothesized that ML systems equipped with multiple cameras may provide reliable and consistent estimations of these kinematic variables, thereby improving risk assessments. We also assumed that these ML approaches could represent valuable input for training AI algorithms capable of automatically classifying the biomechanical risk level. Twenty-eight workers performed standardized lifts under three risk conditions. The results showed significant differences between wearable sensor networks and ML systems for most measures, except at a low risk (LI = 1). Nevertheless, ML consistently showed a closer agreement with reference benchmarks and a lower variability. In terms of the automatic classification performance, ML–based kinematic variables yielded accuracy levels comparable to those obtained with the wearable system. These findings highlight the potential of ML approaches to deliver accurate, repeatable, and cost-effective biomechanical risk assessments, particularly in demanding lifting tasks.

6 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
CCCristina Chieffo
Cristina Chieffo
GCGiorgia Chini
Giorgia Chini
TVTiwana VARRECCHIA
Tiwana VARRECCHIA
IGIrene Gennarelli
Irene Gennarelli
ASAlessio Silvetti
Alessio Silvetti
ARAlberto Ranavolo
Alberto Ranavolo
Spinal cord injury (SCI) causes major challenges to mobility and daily life activities and maintaining balance becomes a crucial issue. Individuals with SCI often need to adopt new strategies to manage balance with minimal discomfort. Sports and physical activities have become one of the most popular rehabilitation methods for people with SCI. The assessment of balance improvement currently relies on subjective evaluation scales, and this study aims to quantitively assess the efficacy of sports on the balance strategies of people with SCI. Twenty-two SCI people remained seated still for 30 s, with their eyes open and closed, and we recorded trunk kinematics with an optoelectronic system before and after a three-months sports program. We also computed trunk total sway length, mean velocity, and sway density curve. Statistical analyses were performed to compare SCI people before and after the rehabilitation program and to investigate any correlations between the trunk balance parameters and the clinical scales. The results demonstrate improvements in static balance, with significant reductions in sway length and mean velocity. In conclusion, our findings confirm the potential of sports to enhance balance in SCI individuals and suggest that integrating structured sports programs into rehabilitation can improve stability and postural control.

30 October 2026 in Prosthesis
Verified
Journal Article
Open access
PDF file
MVMattia Giuseppe Viva
Mattia Giuseppe Viva
AFAlessio Fricano
Alessio Fricano
MPMarco Paoloni
Marco Paoloni
Andrea BernettiAndrea Bernetti
Andrea Bernetti
GGGiuseppe Giannicola
Giuseppe Giannicola
Massimiliano MangoneMassimiliano Mangone
Massimiliano Mangone
Introduction: Adaptive polyarticulated myoelectric hands aim to improve grasp versatility and intuitiveness of use; however, objective clinical and biomechanical evidence supporting their functional impact remains limited. Case presentation: A 75-year-old right-hand-dominant male with a long-standing transradial traumatic amputation and over 30 years of experience with a myoelectric tridigital prosthesis underwent experimental evaluation of an adaptive polyarticulated myoelectric hand (Adam’s Hand®). Methods: Assessment included patient-reported outcome measures (Orthotics and Prosthetics User Survey—Upper Extremity Functional Status (OPUS-UEFS), Trinity Amputation and Prosthesis Experience Scales–Revised (TAPES-R), Disabilities of the Arm, Shoulder and Hand questionnaire (DASH), Short Form Health Survey 36 (SF-36)), standardized performance-based functional tests (Minnesota Manual Dexterity Test (MMDT), Box and Block Test (BBT), Southampton Hand Assessment Procedure (SHAP)), and laboratory-based biomechanical evaluation using optoelectronic motion capture and surface electromyography during Pointing, Hand-to-Mouth, and Grasping tasks. The adaptive prosthesis was tested after rapid artificial intelligence-based calibration, without structured training. Results: Patient-reported outcomes reflected high satisfaction and adaptation to the habitual prosthesis. Performance-based tests favored the habitual device in speed and dexterity, whereas the adaptive hand enabled additional grasp patterns. Biomechanically, the adaptive hand was smoother and faster during reaching, but less stable during grasping. Compensatory trunk and shoulder movements occurred with both devices, with a trend toward less compensation during reaching with the adaptive hand. Conclusions: This case highlights a task-dependent biomechanical profile of an adaptive polyarticulated myoelectric hand under first-use conditions. Rapid calibration may support immediate use for reaching, while optimal grasp control appears to require structured training.

2 January 2026
Verified
Book Chapter
Closed access
PDF file
IGIrene Gennarelli
Irene Gennarelli
GNGianluca Giuseppe Maria De Nardi
Gianluca Giuseppe Maria De Nardi
ARAlberto Ranavolo
Alberto Ranavolo
Micheloni christianMicheloni christian
Micheloni christian
NMNiki Martinel
Niki Martinel