Remote monitoring of gait performance offers possibilities for objective evaluation, and tackling impairment in motor ability, gait, and balance in populations such as elderly, stroke, multiple sclerosis, Parkinson’s, etc. This requires a wearable and unobtrusive system capable of estimating ambulatory gait and balance measures, such as Extrapolated Centre of Mass (XCoM) and dynamic Margin of Stability (MoS). These estimations require knowledge of 3D forces and moments (F&M), and accurate foot positions. Though an existing Ambulatory Gait and Balance System (AGBS) consisting of 3D F&M sensors, and inertial measurement units (IMUs) can be used for the purpose, it is bulky and conspicuous. Resistive pressure sensors were investigated as an alternative to the onboard 3D F&M sensors. Subject specific regression models were built to estimate 3D F&M from 1D plantar pressures. The model was applicable for different walking speeds. Different pressure sensor configurations were studied to optimise system complexity and accuracy. Using resistive sensors only under the toe and heel, we were able to estimate the XCoM with a mean absolute RMS error of 2.2±0.3 cm in the walking direction while walking at a preferred speed, when compared to the AGBS. For the same case, the XCoM was classified as ahead or behind the Base of Support correctly at 97.7 ± 1.7%. In conclusion, the study shows that pressure sensors, minimally under the heel and toe, offer a lightweight and inconspicuous alternative for F&M sensing, towards estimating ambulatory gait and dynamic balance.
31 January 2022 in Neurorehabilitation and Neural Repair
Background: Disambiguation of behavioral restitution from compensation is important to better understand recovery of upper limb motor control post-stroke and subsequently design better interventions. Measuring quality of movement (QoM) during standardized performance assays and functional tasks using kinematic and kinetic metrics potentially allows for this disambiguation. Objectives: To identify longitudinal studies that used kinematic and/or kinetic metrics to investigate post-stroke recovery of reaching and assess whether these studies distinguish behavioral restitution from compensation. Methods: A systematic literature search was conducted using the databases PubMed, Embase, Scopus, and Wiley/Cochrane Library up to July 1st, 2020. Studies were identified if they performed longitudinal kinematic and/or kinetic measurements during reaching, starting within the first 6 months post-stroke. Results: Thirty-two longitudinal studies were identified, which reported a total of forty-six different kinematic metrics. Although the majority investigated improvements in kinetics or kinematics to quantify recovery of QoM, none of these studies explicitly addressed the distinction between behavioral restitution and compensation. One study obtained kinematic metrics for both performance assays and a functional task. Conclusions: Despite the growing number of kinematic and kinetic studies on post-stroke recovery, longitudinal studies that explicitly seek to delineate between behavioral restitution and compensation are still lacking in the literature. To rectify this situation, future studies should measure kinematics and/or kinetics during performance assays to isolate restitution and during a standardized functional task to determine the contributions of restitution and compensation.
20 April 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Ground Reaction Forces (GRF) during gait are measured using expensive laboratory setups such as in-floor or treadmill force plates. Ambulatory measurement of GRF using wearables enables remote monitoring of gait and balance. Here, we propose using an Inertial Measurement Unit (IMU) mounted on the pelvis to estimate the GRF during gait in daily life. Calibration procedures and an Error State Extended Kalman filter (EEKF) were used to transform the accelerations at the center of mass (CoM) to the 3D GRF. The instantaneous 3D GRF was estimated for different overground walking patterns and compared with the 3D GRF measured using the reference ForceShoeTM system. Furthermore, we introduce a changing reference frame called the current step frame that followed the direction of each step made. The frame was defined using movement of the feet, and the estimated GRF were expressed in this new frame. This allowed direct comparison and validation with the reference. The mean and standard deviation of error between the estimated instantaneous 3D GRF and the reference, normalized against the range of the reference, was 12.1±3.3% across all walking tasks, in the horizontal plane. The error margins show that a single pelvis IMU could be a minimal and ambulatory sensing alternative for estimating the instantaneous 3D components of GRF during overground gait.
Low-back pain is a common occupational hazard for industrial workers. Several studies show the advantages of using rigid and soft back-support passive exoskeletons and exosuits (exos) to reduce the low-back loading and risk of injury. However, benefits of using these exos have been shown to be task-specific. Therefore, in this study, we developed a benchmarking approach to assess exos for an industrial workplace at Hankamp Gears B.V. We assessed two rigid (Laevo Flex, Paexo back) and two soft (Auxivo Liftsuit 1.0, and Darwing Hakobelude) exos for tasks resembling the workplace. We measured the assistive moment provided by each exo and their respective influence on muscle activity as well as the user’s perception of comfort and exertion. Ten participants performed four lifting tasks (Static hold, Asymmetric, Squat, and Stoop), while their electromyography and subjective measures were collected. The two rigid exos provided the largest assistance during the Dynamic tasks. Reductions in erector spinae activity were seen to be task-specific, with larger reductions for the two rigid exos. Overall, Laevo Flex offered a good balance between assistive moments, reductions in muscle activity, as well as user comfort and reductions in perceived exertion. Thus, we recommend benchmarking exos for intended use in the industrial workplace. This will hopefully result in a better adoption of the back-support exoskeletons in the workplace and help reduce low-back pain.
20 August 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Muscle fatigue is prevalent across different aspects of daily life. Tracking muscle fatigue is useful to understand muscle overuse and possible risk of injury leading to musculoskeletal disorders. Current fatigue models are not suitable for real-world settings as they are either validated using simulations or non-functional tasks. Moreover, models that capture the changes to muscle activity due to fatigue either assume a linear relationship between muscle activity and muscle force or utilize a simple muscle model. Personalised electromygraphy (EMG)-driven musculoskeletal models (pEMS) offer person-specific approaches to model muscle and joint kinetics during a wide repertoire of daily life tasks. These models utilize EMG, thus capturing central fatigue-dependent changes in multi-muscle bio-electrical activity. However, the peripheral muscle force decay is missing in these models. Thus, we studied the influence of fatigue on a large scale pEMS of the trunk. Eleven healthy participants performed functional asymmetric lifting task. Average peak body-weight normalized lumbosacral moments (BW-LM) were estimated to be 2.55 ± 0.26 Nm/kg by reference inverse dynamics. After complete exhaustion of the lower back, the pEMS overestimated the peak BW-LM by 0.64 ± 0.37 Nm/kg. Then, we developed a time-varying muscle force decay model resulting in a time-varying pEMS (t-pEMS). This reduced the difference between BW-LM estimated by the t-pEMS and reference to 0.49 ± 0.14 Nm/kg. We also showed that five fatiguing contractions are sufficient to calibrate the t-pEMS. Thus, this study presents a person and muscle specific model to track fatigue during functional tasks.