Tetsuya Ishikawa

Dr. Tetsuya Ishikawa

RIKEN SPring-8 Center, Sayō, Hyōgo, Japan
orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
SOShigeki Owada
Shigeki Owada
KTKazuaki Togawa
Kazuaki Togawa
TITakahiro Inagaki
Takahiro Inagaki
THToru Hara
Toru Hara
TTTakashi Tanaka
Takashi Tanaka
Tetsuya IshikawaTetsuya Ishikawa
Tetsuya Ishikawa
The design and performance of a soft X-ray free-electron laser (FEL) beamline of the SPring-8 Compact free-electron LAser (SACLA) are described. The SPring-8 Compact SASE Source test accelerator, a prototype machine of SACLA, was relocated to the SACLA undulator hall for dedicated use for the soft X-ray FEL beamline. Since the accelerator is operated independently of the SACLA main linac that drives the two hard X-ray beamlines, it is possible to produce both soft and hard X-ray FEL simultaneously. The FEL pulse energy reached 110 µJ at a wavelength of 12.4 nm (i.e. photon energy of 100 eV) with an electron beam energy of 780 MeV.

24 October 2024 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
HTHitoshi Tanaka
Hitoshi Tanaka
TWTakahiro Watanabe
Takahiro Watanabe
TAToshinori Abe
Toshinori Abe
NANoriyoshi Azumi
Noriyoshi Azumi
TATsuyoshi Aoki
Tsuyoshi Aoki
Tetsuya IshikawaTetsuya Ishikawa
Tetsuya Ishikawa
SPring-8-II is a major upgrade project of SPring-8 that was inaugurated in October 1997 as a third-generation synchrotron radiation light source. This upgrade project aims to achieve three goals simultaneously: achievement of excellent light source performance, refurbishment of aged systems, and significant reduction in power consumption for the entire facility. A small emittance of 50 pm rad will be achieved by (1) replacing the existing double-bend lattice structure with a five-bend achromat one, (2) lowering the stored beam energy from 8 to 6 GeV, (3) increasing the horizontal damping partition number from 1 to 1.3, and (4) enhancing horizontal radiation damping by installing damping wigglers in long straight sections. The use of short-period in-vacuum undulators allows ultrabrilliant X-rays to be provided while keeping a high-energy spectral range even at the reduced electron-beam energy of 6 GeV. To reduce power consumption, the dedicated, aged injector system has been shut down and the high-performance linear accelerator of SACLA, a compact X-ray free-electron laser (XFEL) facility, is used as the injector of the ring in a time-shared manner. This allows the simultaneous operation of XFEL experiments at SACLA and full/top-up injection of the electron beam into the ring. This paper overviews the concept of the SPring-8-II project, the system design of the light source and the details of the accelerator component design.

10 June 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MYMakina Yabashi
Makina Yabashi
HTHitoshi Tanaka
Hitoshi Tanaka
KTKensuke Tono
Kensuke Tono
Tetsuya IshikawaTetsuya Ishikawa
Tetsuya Ishikawa
This article reports the current status of SACLA, SPring-8 Angstrom Compact free electron LAser, which has been producing stable X-ray Free Electron Laser (XFEL) light since 2012. A unique injector system and a short-period in-vacuum undulator enable the generation of ultra-short coherent X-ray pulses with a wavelength shorter than 0.1 nm. Continuous development of accelerator technologies has steadily improved XFEL performance, not only for normal operations but also for fast switching operation of the two beamlines. After upgrading the broadband spontaneous-radiation beamline to produce soft X-ray FEL with a dedicated electron beam driver, it is now possible to operate three FEL beamlines simultaneously. Beamline/end-station instruments and data acquisition/analyzation systems have also been upgraded to allow advanced experiments. These efforts have led to the production of novel results and will offer exciting new opportunities for users from many fields of science.

1 June 2020 in Chinese Journal of Physics
Verified
Journal Article
Open access
ACAn-Lun Chin
An-Lun Chin
SYShun-Min Yang
Shun-Min Yang
HCHsiang-Hsin Chen
Hsiang-Hsin Chen
MLMin-Tsang Li
Min-Tsang Li
TLTsung-Tse Lee
Tsung-Tse Lee
YHYeukuang Hwu
Yeukuang Hwu

2 February 2018 in Science Advances
Verified
Journal Article
Open access
PDF file
KKKentaro Kuga
Kentaro Kuga
YMYosuke Matsumoto
Yosuke Matsumoto
MOMario Okawa
Mario Okawa
SSShintaro Suzuki
Shintaro Suzuki
TTTakahiro Tomita
Takahiro Tomita
SNSatoru Nakatsuji
Satoru Nakatsuji
A valence critical end point existing near the absolute zero provides a unique case for the study of a quantum version of the strong density fluctuation at the Widom line in the supercritical fluids. Although singular charge and orbital dynamics are suggested theoretically to alter the electronic structure significantly, breaking down the standard quasi-particle picture, this has never been confirmed experimentally to date. We provide the first empirical evidence that the proximity to quantum valence criticality leads to a clear breakdown of Fermi liquid behavior. Our detailed study of the mixed valence compound α-YbAlB4 reveals that a small chemical substitution induces a sharp valence crossover, accompanied by a pronounced non–Fermi liquid behavior characterized by a divergent effective mass and unusual T/B scaling in the magnetization.

1 June 1999 in Journal of Electron Spectroscopy and Related Phenomena
Verified
Journal Article
Closed access
EIE. Ishiguro
E. Ishiguro
HOH. Ohashi
H. Ohashi
LLLi-Jun Lu
Li-Jun Lu
WWW. Watari
W. Watari
MKM. Kamizato
M. Kamizato
Tetsuya IshikawaTetsuya Ishikawa
Tetsuya Ishikawa