Ivana Lapic

Prof. Dr. Ivana Lapic

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2019 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
Ivana LapicIvana Lapic
Ivana Lapic
EPElisa Piva
Elisa Piva
FSFederica Spolaore
Federica Spolaore
FTFrancesca Tosato
Francesca Tosato
MPMichela Pelloso
Michela Pelloso
MPMario Plebani
Mario Plebani
Background: Development of automated analyzers for erythrocyte sedimentation rate (ESR) has imposed the need for extensive validation prior to their implementation in routine practice, to ensure comparability with the reference Westergren method. The aim of our study was to perform the analytical validation of two automated ESR analyzers, the Ves-Matic Cube 200 and the TEST1. Methods: Validation was performed according to the recent International Council for Standardization in Hematology recommendations and included determination of intrarun and inter-run precision, assessment of sample carryover, hemolysis interference, sensitivity to fibrinogen, method comparison with the gold standard Westergren method and stability test. Results: The highest intrarun imprecision was obtained for the low ESR range (33.5% for Ves-Matic Cube; 37.3% for TEST1) while inter-run coefficients of variation on three levels were much better for the TEST1 (0%, 2% and 1.2%) compared to the Ves-Matic Cube 200 on two levels (24.9% and 5.8%). Both Ves-Matic Cube 200 and TEST1 showed no statistically significant difference when compared with Westergren. Bland-Altman analysis yielded overall insignificant mean biases for all comparisons, but a wider dispersion of results and 95% limits of agreement for comparisons including the Ves-Matic Cube 200. Carryover was considered insignificant, while hemolysis had a negative effect on all assessed ESR methods. The highest sensitivity to fibrinogen was observed for the Ves-Matic Cube 200, followed by Westergren and the least sensitive was the TEST1. Conclusions: The obtained results proved the analytical validity of the TEST1 and the Ves-Matic Cube 200, and high comparability with the gold standard Westergren method, showing obvious improvements in standardization of ESR methods.

9 May 2020 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Open access
PDF file
Ivana LapicIvana Lapic
Ivana Lapic
DRDunja Rogić
Dunja Rogić
Mario PlebaniMario Plebani
Mario Plebani
Article Erythrocyte sedimentation rate is associated with severe coronavirus disease 2019 (COVID-19): a pooled analysis was published on 09 May 2020 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (, Ahead of Publication).

19 May 2021 in Journal of Medical Virology
Verified
Journal Article
Open access
PDF file
Ivana LapicIvana Lapic
Ivana Lapic
DŠDragana Šegulja
Dragana Šegulja
DRDunja Rogić
Dunja Rogić
Click on the article title to read more.

21 April 2022 in Journal of Medical Virology
Verified
Journal Article
Closed access
Ivana LapicIvana Lapic
Ivana Lapic
MAMargareta Radić Antolic
Margareta Radić Antolic
IHIvana Horvat
Ivana Horvat
VPVedran Premužić
Vedran Premužić
JPJozefina Palić
Jozefina Palić
RZRenata Zadro
Renata Zadro

1 June 2017 in International Journal of Medical Informatics
Verified
Journal Article
Closed access
Ivana LapicIvana Lapic
Ivana Lapic
GJGordana Fressl Juroš
Gordana Fressl Juroš
IRIvana Rako
Ivana Rako
DRDunja Rogić
Dunja Rogić

29 November 2021 in Multiple Sclerosis and Related Disorders
Verified
Journal Article
Closed access
MSMagdalena Krbot Skorić
Magdalena Krbot Skorić
DRDunja Rogic
Dunja Rogic
Ivana LapicIvana Lapic
Ivana Lapic
SSSegulja Segulja
Segulja Segulja
Mario HabekMario Habek
Mario Habek