Jakub Hlosta

Dr. Jakub Hlosta

Faculty of Mining and Geology, VSB - Technical University of Ostrava, Ostrava, Moravskoslezský Kraj, Czech Republic
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2020 in Processes
Verified
Journal Article
Open access
PDF file
Jakub HlostaJakub Hlosta
Jakub Hlosta
Lucie JezerskaLucie Jezerska
Lucie Jezerska
JRJiri Rozbroj
Jiri Rozbroj
DŽDavid Žurovec
David Žurovec
JNJan Nečas
Jan Nečas
JZJiří Zegzulka
Jiří Zegzulka
This paper’s goal was to select methods and a calibration procedure which would lead to the determination of relevant parameters of a discrete element method (DEM) and virtual material creation. Seven particulates were selected with respect to their shape (spherical and non-spherical), size and density. The first calibration experiment involved “packing test” to determine the shape accuracy and bulk density of virtual packed particulates. The series of simulations were compared with real experiments, and the size, shape and density of virtual particles were optimized. Using three apparatuses, the input parameter values were experimentally determined for a contact model that defines the behavior of particulates in DEM simulations. The research part of the paper examines the influence of factors such as particle number; pile formation method; and the method of evaluation of the angle of repose on the process of the calibration of virtual material. The most reproducible results were achieved by the “pilling” method and by the rotating drum—both evaluated by the geometric method. However, it is always advisable to make an overall visual comparison of the slope shape between the calibration simulation and the experimental curves. The bowl’s diameter to particle size ratio should be greater than 25, and the calibration experiment should contain approximately 4000 particles to ensure representative results during angle of repose calibration experiment.

1 July 2018 in Chemical Engineering Research and Design
Verified
Journal Article
Closed access
Jakub HlostaJakub Hlosta
Jakub Hlosta
DŽDavid Žurovec
David Žurovec
JRJiri Rozbroj
Jiri Rozbroj
ÁRÁlvaro Ramírez-Gómez
Álvaro Ramírez-Gómez
JNJan Nečas
Jan Nečas
JZJiří Zegzulka
Jiří Zegzulka

5 February 2020 in Processes
Verified
Journal Article
Open access
PDF file
Jakub HlostaJakub Hlosta
Jakub Hlosta
Lucie JezerskaLucie Jezerska
Lucie Jezerska
JRJiri Rozbroj
Jiri Rozbroj
DŽDavid Žurovec
David Žurovec
JNJan Nečas
Jan Nečas
JZJiří Zegzulka
Jiří Zegzulka
The process of homogenization of particulates is an indispensable part of many industrial processes, and, therefore, it is necessary to pay a special attention to this area and develop it. This paper deals with a complex study of homogenization of particulate matters in a rotary drum in terms of shape, size, and density of particles. In addition, the influence of operating parameters, such as drum filling capacity, rotational speed, and drum filling pattern are also investigated. Studies of reproducibility of discrete element method simulations, effects of rotary drum sizes or effects of drum volumetric filling to the mixture homogeneity index were also carried out. In general, the least satisfactory values of the homogeneity index resulted from the mixing of particles with different densities. The dominating factor of homogenization was the drum filling-up degree. The course of the homogeneity index in 140, 280, and 420 mm drums was very similar and after five revolutions of the drum, identical values of the homogeneity index were achieved for all the drum diameters. The optimal drum filling-up degree is at 40–50% for the spherical particles and 30–40% for the sharp-edged particles. The repeatability of simulations showed the maximum relative standard deviation of the homogeneity index at 0.6% from ten simulation repetitions with the same parametric conditions.

30 July 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Jakub HlostaJakub Hlosta
Jakub Hlosta
KHKamila Hrabovská
Kamila Hrabovská
JRJiří Rozbroj
Jiří Rozbroj
JNJan Nečas
Jan Nečas
DŽDavid Žurovec
David Žurovec
OŽOndřej Životský
Ondřej Životský
The paper deals with the economic optimisation of ferrite powder preparation during producing hard ferrite magnets. The magnetic properties of ferrites are investigated by replacing feedstock and reducing calcination temperature and particles in the order of tens of microns. The granulates about 8–10 mm in size were calcined for 2 h in the temperature range from 1100 °C to 1300 °C and additionally crushed and milled to an average particle size of about 80–90 µm. The scanning electron microscopy images confirmed the agglomerates of particles with different shapes and sizes in tens of µm. The X-ray diffraction measurements revealed that, besides the SrFe12O19 and BaFe12O19 phases, there was also the presence of 2–39% hematite. The highest values of maximum energy product (BH)max = 930 J/m3 and remanent magnetic induction Br = 72.8 mT were obtained at a calcination temperature of 1300 °C. The Henkel plots confirmed the presence of exchange-coupling and dipolar magnetic interactions at lower and higher magnetic fields, respectively. The strength of interactions was also dependent on the calcination temperature. Replacing strontium with barium led to a deterioration of the magnetic parameters, which were optimal at a lower calcination temperature (1100 °C). This phenomenon was partly overcome by reducing the mean particle size of Ba-based hexaferrites to 45–50 µm.

23 July 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
WKWeronika Kruszelnicka
Weronika Kruszelnicka
Jakub HlostaJakub Hlosta
Jakub Hlosta
Jan DivišJan Diviš
Jan Diviš
Łukasz GierzŁukasz Gierz
Łukasz Gierz
The knowledge of a grinder structure, its performance parameters and characteristics of biomaterials breakage are crucial for this research whose aim is to determine the dependencies between performance parameters and comminution indicators. The aim of this study is to investigate the relationships between multi-disc mill performance parameters such as discs angular speed, batch dosing speed and comminution characteristics: power consumption, specific energy consumption, throughput and size reduction ratio. To achieve these goals, an experiment was conducted on a five-disc mill with a special monitoring system. The research program was established, with disc angular speed at different configurations and different batch dosing speeds. The results show that power consumption, specific energy consumption and size reduction ratio depend on the total increase in angular speed of discs SΔω in such a way that an increase in SΔω causes an increase in the abovementioned comminution indicators. In turn, an increase in batch dosing speed W causes an increase in throughput. The fitting curves of comminution indicators in dependence of selected performance parameters are also presented in this study.

1 November 2022 in Advances in Science and Technology Research Journal
Verified
Journal Article
Open access
WKWeronika Kruszelnicka
Weronika Kruszelnicka
Jan DivišJan Diviš
Jan Diviš
Jakub HlostaJakub Hlosta
Jakub Hlosta
Łukasz GierzŁukasz Gierz
Łukasz Gierz
DŽDavid Žurovec
David Žurovec
Computer simulation of bulk materials behavior, including comminution and fragmentation, using DEM has been growing fast, recently. One of the important tasks to get the reliable simulation results is to provide proper materials and contact parameters, which need to be determined in a series of...