Marek Jaszczur

Dr. Marek Jaszczur

AGH University of Science and Technology
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
Robert HanusRobert Hanus
Robert Hanus
MZMarcin Zych
Marcin Zych
MKMaciej Kusy
Maciej Kusy
Marek JaszczurMarek Jaszczur
Marek Jaszczur
LPLeszek Petryka
Leszek Petryka

9 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
QHQusay Hassan
Qusay Hassan
IAImad Saeed Abdulrahman
Imad Saeed Abdulrahman
HSHayder M. Salman
Hayder M. Salman
OOOlushola Tomilayo Olapade
Olushola Tomilayo Olapade
Marek JaszczurMarek Jaszczur
Marek Jaszczur
Green hydrogen production is essential to meeting the conference of the parties’ (COP) decarbonization goals; however, this method of producing hydrogen is not as cost-effective as hydrogen production from fossil fuels. This study analyses an off-grid photovoltaic energy system designed to feed a proton-exchange membrane water electrolyzer for hydrogen production to evaluate the optimal electrolyzer size. The system has been analyzed in Baghdad, the capital of Iraq, using experimental meteorological data. The 12 kWp photovoltaic array is positioned at the optimal annual tilt angle for the selected site. The temperature effect on photovoltaic modules is taken into consideration. Several electrolyzers with capacities in the range of 2–14 kW were investigated to assess the efficiency and effectiveness of the system. The simulation process was conducted using MATLAB and considering the project life span from 2021 to 2035. The results indicate that various potentially cost-competitive alternatives exist for systems with market combinations resembling renewable hydrogen wholesale. It has been found that the annual energy generated by the analyzed photovoltaic system is 18,892 kWh at 4313 operating hours, and the obtained hydrogen production cost ranges from USD 5.39/kg to USD 3.23/kg. The optimal electrolyzer capacity matches a 12 kWp PV system equal to 8 kW, producing 37.5 kg/year/kWp of hydrogen for USD 3.23/kg.

29 March 2018 in Environmental Science and Pollution Research
Verified
Journal Article
Open access
PDF file
KSKatarzyna Styszko
Katarzyna Styszko
Marek JaszczurMarek Jaszczur
Marek Jaszczur
JTJanusz Roman Teneta
Janusz Roman Teneta
QHQusay Hassan
Qusay Hassan
PBPaulina Burzyńska
Paulina Burzyńska
LSLucyna Samek
Lucyna Samek
Solid particles impair the performance of the photovoltaic (PV) modules. This results in power losses which lower the efficiency of the system as well as the increases of temperature which additionally decreases the performance and lifetime. The deposited dust chemical composition, concentration and formation of a dust layer on the PV surface differ significantly in reference to time and location. In this study, an evaluation of dust deposition on the PV front cover glass during the non-heating season in one of the most polluted European cities, Kraków, was performed. The time-dependent particle deposition and its correlation to the air pollution with particulate matter were analysed. Dust deposited on several identical PV modules during variable exposure periods (from 1 day up to 1 week) and the samples of total suspended particles (TSP) on quartz fibre filters using a low volume sampler were collected during the non-heating season in the period of 5 weeks. The concentration of TSP in the study period ranged between 12.5 and 60.05 μg m−3 while the concentration of PM10 observed in the Voivodeship Inspectorate of Environmental Protection traffic station, located 1.2 km from the TSP sampler, ranged from 14 to 47 μg m−3. It was revealed that dust deposition density on a PV surface ranged from 7.5 to 42.1 mg m−2 for exposure periods of 1 day while the measured weekly dust deposition densities ranged from 25.8 to 277.0 mg m−2. The precipitation volume and its intensity as well as humidity significantly influence the deposited dust. The rate of dust accumulation reaches approximately 40 mg m−2day−1 in the no-precipitation period and it was at least two times higher than fluxes calculated on the basis of PM10 and TSP concentrations which suggest that additional forces such as electrostatic forces significantly influence dust deposition.

20 April 2018 in Environmental Science and Pollution Research
Verified
Journal Article
Open access
PDF file
Marek JaszczurMarek Jaszczur
Marek Jaszczur
JTJanusz Roman Teneta
Janusz Roman Teneta
KSKatarzyna Styszko
Katarzyna Styszko
QHQusay Hassan
Qusay Hassan
PBPaulina Burzyńska
Paulina Burzyńska
NŁNatalia Łopian
Natalia Łopian
The maximisation of the efficiency of the photovoltaic system is crucial in order to increase the competitiveness of this technology. Unfortunately, several environmental factors in addition to many alterable and unalterable factors can significantly influence the performance of the PV system. Some of the environmental factors that depend on the site have to do with dust, soiling and pollutants. In this study conducted in the city centre of Kraków, Poland, characterised by high pollution and low wind speed, the focus is on the evaluation of the degradation of efficiency of polycrystalline photovoltaic modules due to natural dust deposition. The experimental results that were obtained demonstrated that deposited dust-related efficiency loss gradually increased with the mass and that it follows the exponential. The maximum dust deposition density observed for rainless exposure periods of 1 week exceeds 300 mg/m2 and the results in efficiency loss were about 2.1%. It was observed that efficiency loss is not only mass-dependent but that it also depends on the dust properties. The small positive effect of the tiny dust layer which slightly increases in surface roughness on the module performance was also observed. The results that were obtained enable the development of a reliable model for the degradation of the efficiency of the PV module caused by dust deposition. The novelty consists in the model, which is easy to apply and which is dependent on the dust mass, for low and moderate naturally deposited dust concentration (up to 1 and 5 g/m2 and representative for many geographical regions) and which is applicable to the majority of cases met in an urban and non-urban polluted area can be used to evaluate the dust deposition-related derating factor (efficiency loss), which is very much sought after by the system designers, and tools used for computer modelling and system malfunction detection.

1 May 2016 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
Marek JaszczurMarek Jaszczur
Marek Jaszczur
MRMarc A. Rosen
Marc A. Rosen
Tomasz SliwaTomasz Sliwa
Tomasz Sliwa
MDMichał Dudek
Michał Dudek
LPLudwik Pieńkowski
Ludwik Pieńkowski

25 November 2019 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
Marek JaszczurMarek Jaszczur
Marek Jaszczur
AKAmbalika Koshti
Ambalika Koshti
WNWeronika Nawrot
Weronika Nawrot
PSPatrycja Sędor
Patrycja Sędor