Jong Hyun Kim

Dr. Jong Hyun Kim

Digital Healthcare Group, Korea Institute of Industrial Technology, Cheonan, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

4 September 2026 in Electronics
Verified
Journal Article
Open access
PDF file
JKJong Hyun Kim
Jong Hyun Kim
CLChang Gi Lee
Chang Gi Lee
KJKwangtae Jung
Kwangtae Jung
This study proposes a markerless, single-camera depth-sensing system for digitally quantifying pelvic-balance ability in the Trendelenburg test, and verifies its accuracy and reliability against a marker-based motion capture (MC) reference and manual measurement (MM) in 16 healthy adults. A paired-samples t-test confirmed that the pre-correction bias between MC and DC was significantly different from zero (p < 0.001), whereas the post-correction bias between MC and the corrected DC (cDC) was not (p = 0.791; LOSO p = 0.771), directly confirming that a correction coefficient (a = 89.42%) derived from this systematic bias successfully removed it: Bland–Altman analysis showed that the mean bias (−5.11 mm) was reduced to near zero after correction (0.18 mm), and Lin’s concordance correlation coefficient (CCC) improved correspondingly from 0.944 to 0.981. These findings were consistent with intraclass correlation coefficient (ICC) analysis, which showed excellent consistency (0.980) and absolute agreement (0.946) with MC even before correction, further improving to 0.982 after correction. All improvements were confirmed using Leave-One-Subject-Out (LOSO) cross-validation (CCC = 0.980; absolute-agreement ICC = 0.981; bias = 0.21 mm), indicating that they are not an artifact of evaluating the correction on the same data used to derive it. By contrast, MM showed poor reliability and agreement with MC (CCC = 0.258; ICC = 0.264–0.440), underscoring the limitations of visual, examiner-based assessment. These findings indicate that the proposed single-camera depth-sensing system offers a convenient, markerless alternative to marker-based motion capture, with accuracy and reliability suitable for practical deployment, and that the verification–correction methodology provides a generalizable approach for improving the accuracy of similar low-cost digital measurement systems.

17 March 2026 in Medical Lasers
Verified
Journal Article
Open access
PDF file
JKJong Hyun Kim
Jong Hyun Kim
HKHohyun Keum
Hohyun Keum
JKJinhwan Kim
Jinhwan Kim
CLChang Gi Lee
Chang Gi Lee
JCJanghee Choi
Janghee Choi
HJHoon Jeong
Hoon Jeong
Jong Hyun Kim, Hohyun Keum, Jinhwan Kim, Chang Gi Lee, Janghee Choi, Kwang Bok Kim, Hoon Jeong. Med Lasers 2026;15:1-12. https://doi.org/10.25289/ML.26.003