Jingyi Wu

Dr. Jingyi Wu

Carnegie Mellon University
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2024 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
SRShidhartho Roy
Shidhartho Roy
JWJingyi Wu
Jingyi Wu
JCJiaming Cao
Jiaming Cao
JDJoel Disu
Joel Disu
SBSharadhi Bharadwaj
Sharadhi Bharadwaj
SWSossena Wood
Sossena Wood
Near-infrared spectroscopy (NIRS) is an optical method that uses light–tissue interaction to measure optical properties and characteristics. It is sensitive to changes brought on by variations in hemoglobin concentration and oxygenation, the latter referring to the level of oxygen in the blood. NIRS operates on the principle of changes in light intensity due to the absorption of hemoglobin and scattering in the imaged tissue. This sensitivity to light intensity is accomplished using at least two or more wavelengths, primarily within an optical window of 650 to 900 nm,1,2 where absorption spectra of oxyhemoglobin, deoxyhemoglobin, water, and melanin are present. The promise of portability and appropriateness for continuous bedside monitoring has propelled NIRS to its growing popularity in various domains, ranging from clinical studies in adult populations,3,4 multi-modal recording,5,6 cognitive research,7,8 and pediatric populations9,10 to exercise monitoring.11,12 Although NIRS and other diffuse optical methods are well-established imaging techniques,13,14 their application tends to produce reliable and consistent results for group-level analysis but may vary for single subject-level analysis due to inherent variability. This variability may be partly attributed to differences in melanin, a primary determinant of skin color and the product of melanocytes in the skin’s basal layer.15 – 17

16 September 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JWJingyi Wu
Jingyi Wu
STSyeda Tabassum
Syeda Tabassum
WBWilliam L. Brown
William L. Brown
SWSossena Wood
Sossena Wood
JYJason Yang
Jason Yang
JKJana M Kainerstorfer
Jana M Kainerstorfer
Diffuse correlation spectroscopy (DCS) has been widely explored for its ability to measure cerebral blood flow (CBF), however, mostly under the assumption that the human head is homogenous. In addition to CBF, knowledge of extracerebral layers, such as skull thickness, can be informative and crucial for patient with brain complications such as traumatic brain injuries. To bridge the gap, this study explored the feasibility of simultaneously extracting skull thickness and flow in the cortex layer using DCS. We validated a two-layer analytical model that assumed the skull as top layer with a finite thickness and the brain cortex as bottom layer with semi-infinite geometry. The model fitted for thickness of the top layer and flow of the bottom layer, while assumed other parameters as constant. The accuracy of the two-layer model was tested against the conventional single-layer model using measurements from custom made two-layer phantoms mimicking skull and brain. We found that the fitted top layer thickness at each source detector (SD) distance is correlated with the expected thickness. For the fitted bottom layer flow, the two-layer model fits relatively consistent flow across all top layer thicknesses. In comparison, the conventional one-layer model increasingly underestimates the bottom layer flow as top layer thickness increases. The overall accuracy of estimating first layer thickness and flow depends on the SD distance in relationship to first layer thickness. Lastly, we quantified the influence of uncertainties in the optical properties of each layer. We found that uncertainties in the optical properties only mildly influence the fitted thickness and flow. In this work we demonstrate the feasibility of simultaneously extracting of layer thickness and flow using a two-layer DCS model. Findings from this work may introduce a robust and cost-effective approach towards simultaneous bedside assessment of skull thickness and cerebral blood flow.

1 November 2023 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
JWJingyi Wu
Jingyi Wu
JMJ. Chris McKnight
J. Chris McKnight
EBEva-Maria Bønnelycke
Eva-Maria Bønnelycke
Gerardo BoscoGerardo Bosco
Gerardo Bosco
Tommaso Antonio GiaconTommaso Antonio Giacon
Tommaso Antonio Giacon
JKJana M Kainerstorfer
Jana M Kainerstorfer
Oxygen level in the arterial blood (SaO2), namely the percentage of oxygen-bound hemoglobin out of the total hemoglobin, is one of the most important health indicators in patient care. Its precise measurement requires an arterial blood draw to be processed by a blood gas analyzer but in clinics or home settings, it is often estimated noninvasively with a finger pulse oximeter, which is denoted by SpO2 (“p” indicates pulse oximetry).1 The underlying principle behind pulse oximetry is diffuse optical spectroscopy—by shining light at two wavelengths (usually red and infrared) into the finger and detecting the intensity changes from the heart pulsation, SpO2 can be calculated by utilizing the fact that light at different wavelengths is absorbed differently based on the amount of oxygen-bound hemoglobin.2

19 August 2024 in Biomedical Optics Express
Verified
Journal Article
Open access
JWJingyi Wu
Jingyi Wu
GSGopika Satish
Gopika Satish
ARAlexander Ruesch
Alexander Ruesch
BJBaptiste Jayet
Baptiste Jayet
KKKatarzyna Komolibus
Katarzyna Komolibus
JKJana M Kainerstorfer
Jana M Kainerstorfer
Transabdominal fetal pulse oximetry offers a promising approach to improve fetal monitoring and reduce unnecessary interventions. Utilizing realistic 3D geometries derived from MRI scans of pregnant women, we conducted photon simulations to determine optimal source-detector configurations for detecting fetal heart rate and oxygenation. Our findings demonstrate the theoretical feasibility of measuring fetal signals at depths up to 30 mm using source-detector (SD) distances greater than 100 mm and wavelengths between 730 and 850 nm. Furthermore, we highlight the importance of customizing SD configurations based on fetal position and maternal anatomy. These insights pave the way for enhanced non-invasive fetal monitoring in clinical application.

1 January 2024 in Neurophotonics
Verified
Journal Article
Open access
PDF file
NKNikita Kedia
Nikita Kedia
MMMichael M. McDowell
Michael M. McDowell
JYJason Yang
Jason Yang
JWJingyi Wu
Jingyi Wu
RFRobert M. Friedlander
Robert M. Friedlander
JKJana M Kainerstorfer
Jana M Kainerstorfer
Noninvasive bedside compatible tools to monitor cerebral health could greatly impact clinical care by reducing the need for invasive procedures. Diffuse transcutaneous optical modalities are becoming increasingly popular tools to monitor cerebral health. One such modality, diffuse correlation spectroscopy (DCS) uses the temporal fluctuations of scattered near-infrared light caused by moving red blood cells to monitor relative changes in cerebral blood flow (rCBF) in the microvasculature. These devices are noninvasive and easy to use, making them an attractive option for clinical applications.1 – 4 The use of DCS in clinical settings has been explored for various applications, such as predicting intracranial pressure (ICP),5 – 7 measuring dynamic cerebral autoregulation in stroke patients,8 monitoring intraventricular hemorrhage vulnerability in newborns,9 and estimating critical closing pressure (CrCP).10,11

29 July 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
YQYutian Qin
Yutian Qin
JWJingyi Wu
Jingyi Wu
EBEli Bulger
Eli Bulger
JCJiaming Cao
Jiaming Cao
HDHamid Dehghani
Hamid Dehghani
JKJana M Kainerstorfer
Jana M Kainerstorfer
Diffuse optical tomography (DOT) enhances the localization accuracy of neural activity measured with electroencephalography (EEG) while preserving EEG’s high temporal resolution. However, the spatial resolution of reconstructed activity diminishes for deeper neural sources. In this study, we analyzed DOT-enhanced EEG localization of neural sources modeled at depths ranging from 11-25 mm in simulations. Our findings reveal systematic biases in reconstructed depth related to DOT channel length. To address this, we developed a data-informed method for selecting DOT channels to improve the spatial accuracy of DOT-enhanced EEG reconstruction. Using our method, the average absolute reconstruction depth errors of DOT reconstruction across all depths are 0.9 ± 0.6 mm, 1.2 ± 0.9 mm, and 1.2 ± 1.1 mm under noiseless, low-level noise, and high-level noise conditions, respectively. In comparison, using fixed channel lengths resulted in errors of 2.6 ± 1.5 mm, 5.0 ± 2.6 mm, and 7.3 ± 4.5 mm under the same conditions. Consequently, our method improved the depth accuracy of DOT reconstructions and facilitated the use of more accurate spatial priors for EEG reconstructions, enhancing the overall precision of the technique.