Boron neutron capture therapy (BNCT) can selectively destroy tumor cells while minimizing damage to normal tissue through boron neutron capture reactions. Real-time determination and localization of the in vivo boron dose during treatment is a critical challenge in BNCT. A promising solution involves imaging the 478 keV prompt gamma rays emitted from these capture reactions. This study presents a comprehensive simulation-based design of a Si/TlBr semiconductor Compton camera system for 478 keV prompt gamma-ray imaging in clinical BNCT. The design process includes optimization of detector geometry using isotropic, monoenergetic 478 keV gamma-ray sources; development of neutron and photon shielding under therapeutic neutron beam irradiation of a head phantom; and evaluation of imaging performance under clinically relevant conditions with low in vivo 10B concentrations. The results provide valuable insights to support the further development of Compton camera systems for BNCT applications.
Objective. Boron neutron capture therapy (BNCT) is a promising radiotherapy modality that effectively targets cancer cells through boron neutron capture reactions. Real-time determination and localization of the in vivo boron dose during treatment play an important role in BNCT. This study aims to investigate the feasibility of neural network-based Compton event filtering to enhance 478 keV prompt gamma-ray imaging for BNCT under high-background radiation conditions with a Si/TlBr Compton camera. Approach. Monte Carlo simulations were performed using PHITS to generate signal and noise Compton events under clinically relevant neutron irradiation. Fully connected neural network models were trained to classify signal and noise events. The filtered events were then used for Compton image reconstruction, and quantitative imaging performance was evaluated using event retention rate with 10 B concentration and image quality metrics. Results. The neural network models achieved stable classification performance with area under the ROC curve values exceeding 0.8. The Compton event retention rate shows a strong linear relationship with tumor 10 B concentration, demonstrating the quantitative capability. Image reconstruction results indicate improved image quality in tumor regions, although additional background artifacts were observed. Significance. The proposed neural network-based Compton event filtering method provides an effective preprocessing strategy for data reduction and accelerated reconstruction. While further refinement is required for practical clinical application, this approach represents a promising step toward Compton camera-based prompt gamma-ray imaging for real-time in vivo boron dose visualization in BNCT.
Carbon-ion radiotherapy utilizes high-energy carbon ions to deliver a precise dose to tumors, offering improved treatment accuracy and reduced damage to surrounding healthy tissues compared to traditional photon radiotherapies. Due to the high magnetic rigidity of carbon ions, transporting therapeutic carbon-ion beams with high angular flexibility is more challenging than with lighter ions, such as protons. Recently, irradiation of carbon ions with flexible angular selections has been achieved through rotating gantry systems, but these require large mechanical frames to house a series of beam transport elements for rotation around the treatment couch. A static beam delivery system compatible with multiple irradiation angles is a promising alternative to the rotating gantry system, offering potential for miniaturization and cost reduction of carbon-ion radiotherapy facilities. This study investigates a static gantry system concept, using electromagnets arranged in a circular configuration around the treatment couch to enable multiple angular irradiations of therapeutic carbon-ion beams. However, the beam optics design for such a static gantry system is challenging, as each irradiation angle must produce a beam with uniform size at the isocenter. To address this, the study proposes a beam optics optimization strategy using a genetic algorithm for efficient optimization. The results of the optimization demonstrate the potential of the proposed static gantry system.