Jean-Michel POUVESLE

Dr. Jean-Michel POUVESLE

GREMI CNRS-Université d'Orléans
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2016 in Plasma Sources Science and Technology
Verified
Journal Article
Closed access
PDF file
ABAnne Bourdon
Anne Bourdon
TDThibault Darny
Thibault Darny
FPFrançois Pechereau
François Pechereau
Jean-Michel POUVESLEJean-Michel POUVESLE
Jean-Michel POUVESLE
PVPedro Viegas
Pedro Viegas
ERERIC ROBERT
ERIC ROBERT
This paper presents a combined 2D numerical and experimental study of the influence of admixture on the dynamics of a He– discharge in the 10 cm long dielectric tube of a plasma gun set-up. First, the comparison between experiments and simulations is carried out on the ionization front propagation velocity in the tube. The importance of taking into account a detailed kinetic scheme for the He– mixture in the simulations to obtain a good agreement with the experiments is put forward. For the μ s driven plasma gun, the two- and three-body Penning reactions occurring in the plasma column behind the ionization front, are shown to play a key role on the discharge dynamics. In the experiments and simulations, the significant influence of the amplitude of the applied voltage on the ionization front propagation velocity is observed. As the amount of varies, simulation results show that the ionization front velocity, depends on a complex coupling between the kinetics of the discharge, the photoionization and the 2D structure of the discharge in the tube. Finally, the time evolution of axial and radial components of the electric field measured by an electro-optic probe set outside the tube are compared with simulation results. A good agreement is obtained on both components of the electric field. In the tube, simulations show that the magnitude of the axial electric field on the discharge axis depends weakly on the amount of conversely to the magnitude of the off-axis peak electric field. Both, simulations and first measurements in the tube or within the plasma plume show peak electric fields of the order of 45 kV·cm −1 .

15 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TMThomas Maho
Thomas Maho
RBRaphaelle Binois
Raphaelle Binois
FBFabienne Brulé-Morabito
Fabienne Brulé-Morabito
MDMaryvonne Demasure
Maryvonne Demasure
Claire DouatClaire Douat
Claire Douat
ERERIC ROBERT
ERIC ROBERT
This work is a contribution to the development and implementation of non-thermal plasma technology for decontamination in the perspective of nosocomial and chronic wound innovative therapies. Multi jets devices based on Plasma Gun® technology in static and scanning operation modes and bacterial lawns inoculated with resistant and non-resistant bacterial strains were designed and used. A pilot toxicity study exploring plasma treatment of wound bearing patients, performed with a low voltage plasma applicator, is documented as a first step for the translation of in vitro experiments to clinical care. Bacterial inactivation was demonstrated for Staphylococcus aureus, Pseudomonas aeruginosa and drug resistant S. aureus, P. aeruginosa and Escherichia Coli strains collected from patient wounds at Orleans (France) hospital. A few square centimeter large contaminated samples were inactivated following a single plasma exposure as short as one minute. Samples inoculated with a single but also a mix of three resistant pathogens were successfully inactivated not only right after their contamination but for mature lawns as well. Similar bactericidal action was demonstrated for antibiotic-resistant and non-resistant P. aeruginosa. The time exposure dependent increase of the inhibition spots, following multi jets exposure, is discussed as either the accumulation of reactive species or the likely combinatory action of both the reactive species and transient electric field delivery on inoculated samples.

16 January 2020 in Cancers
Verified
Journal Article
Open access
PDF file
Thai-Hoa CHUNGThai-Hoa CHUNG
Thai-Hoa CHUNG
Augusto StancampianoAugusto Stancampiano
Augusto Stancampiano
KSKYRIAKOS SKLIAS
KYRIAKOS SKLIAS
Kristaq GazeliKristaq Gazeli
Kristaq Gazeli
FAFranck André
Franck André
LPLluís Miquel Plà-Aragonès
Lluís Miquel Plà-Aragonès
The effectiveness of electrochemotherapy (ECT) in local eradication of tumours in human and veterinary medicine has been proven. ECT consists of increasing the uptake of cytotoxic drugs by means of pulsed electric fields (PEFs) that transiently permeabilise the cell membrane. Still, this tumour treatment includes some drawbacks that are linked to the characteristics of the intense electric pulses (EPs) used. Meanwhile, the emerging field of cancer therapies that are based on the application of non-thermal plasmas (NTP) has recently garnered interest because of their potentialities as rich sources of reactive species. In this work, we investigated the potential capabilities of the combined application of indirect NTP treatment and microsecond PEFs (µsPEFs) to outperform in vitro cell electropermeabilisation, the basis of ECT. Thus, phosphate-buffered saline (PBS) was plasma-treated (pPBS) and used afterwards to explore the effects of its combination with µsPEFs. Analysis of two different cell lines (DC-3F Chinese hamster lung fibroblasts and malignant B16-F10 murine melanoma cells), by flow cytometry, revealed that this combination resulted in significant increases of the level of cell membrane electropermeabilisation, even at very low electric field amplitude. The B16-F10 cells were more sensitive to the combined treatment than DC-3F cells. Importantly, the percentage of permeabilised cells reached values similar to those of cells exposed to classical electroporation field amplitude (1100 V/cm) when the cells were treated with pPBS before and after being exposed only to very low PEF amplitude (600 V/cm). Although the level of permeabilisation of the cells that are treated by the pPBS and the PEFs at 600 V/cm is lower than the level reached after the exposure to µsPEFs alone at 1100 V/cm, the combined treatment opens the possibility to reduce the amplitude of the EPs used in ECT, potentially allowing for a novel ECT with reduced side-effects.

14 September 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Augusto StancampianoAugusto Stancampiano
Augusto Stancampiano
TGTommaso Gallingani
Tommaso Gallingani
Matteo GherardiMatteo Gherardi
Matteo Gherardi
Zdenko MachalaZdenko Machala
Zdenko Machala
PMPAUL MAGUIRE
PAUL MAGUIRE
ERERIC ROBERT
ERIC ROBERT
The interaction of plasmas and liquid aerosols offers special advantages and opens new perspectives for plasma–liquid applications. The paper focuses on the key research challenges and potential of plasma-aerosol interaction at atmospheric pressure in several fields, outlining opportunities and benefits in terms of process tuning and throughputs. After a short overview of the recent achievements in plasma–liquid field, the possible application benefits from aerosol injection in combination with plasma discharge are listed and discussed. Since the nature of the chemicophysical plasma-droplet interactions is still unclear, a multidisciplinary approach is recommended to overcome the current lack of knowledge and to open the plasma communities to scientists from other fields, already active in biphasic systems diagnostic. In this perspective, a better understanding of the high chemical reactivity of gas–liquid reactions will bring new opportunities for plasma assisted in-situ and on-demand reactive species production and material processing.

1 October 2020 in Plasma Sources Science and Technology
Verified
Journal Article
Closed access
AOAzadeh Valinataj Omran
Azadeh Valinataj Omran
GBGiovanni Busco
Giovanni Busco
LRLoïck Ridou
Loïck Ridou
SDSébastien Dozias
Sébastien Dozias
CGCatherine Grillon
Catherine Grillon
ERERIC ROBERT
ERIC ROBERT
Several attempts have been made to deliver reactive oxygen and nitrogen species (RONS) produced by non-thermal plasma onto large surfaces in a controllable way compatible with skin treatments. In this paper, the effect of pulse frequency, in the range 0.5–20 kHz, on the discharge behavior was studied on skin tissue models to evaluate potential treatment changes. This has been done through electrical characterization, visualization of the helium flow (by Schlieren technique), produced plasma jet modifications (ICCD imaging) and RONS measurements. The results show that, in addition to its well known important role in the production of the chemical species, the applied discharge frequency plays a very significant role in the size of the treated surface. An enhancement of NO * , OH * and O * production in the gas phase at the higher frequency is reported and assigned to the stronger mixing of the helium flow with ambient air. The efficacy of plasma jet on transporting RONS on/into agarose gel and pig skin has been evaluated. The distribution of the reactive species on the target, or passing through, is strongly dependent on the discharge frequency and consequently induces pH variations. The present study supports a new way for enlarging the treated surface by using a simple jet at high frequency in the 20 kHz range, leading, with appropriate gas flow and distance to target, to conditions of RONS production that are compatible with potential uses for biomedical or cosmetic applications.

24 November 2021 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
PBPeter Bruggeman
Peter Bruggeman
Annemie  BogaertsAnnemie Bogaerts
Annemie Bogaerts
Jean-Michel POUVESLEJean-Michel POUVESLE
Jean-Michel POUVESLE
ERERIC ROBERT
ERIC ROBERT
ESEndre Szili
Endre Szili