The spread of per- and polyfluoroalkyl substances (PFAS) in the environment poses a severe threat to soil organisms, aquatic life, and human health. Many PFAS compounds are mobile and easily transported from soils to groundwater and further to surface waters. Leaching tests are valuable tools for assessing the site-specific leaching behaviour of contaminants. Here, we report the results of an evaluation of two standardized leaching tests for PFAS-contaminated soil materials: the batch test (ISO 21268-2:2019) using either demineralized water or 1 mM CaCl2 as leachants (liquid-to-solid (L/S) ratio of 10) and the up-flow percolation test (ISO 21268-3:2019) using 1 mM CaCl2 as leachant. One field-contaminated soil and three spiked (12 PFAS compounds) soils (aged 5 months) were included in the study. Desorption kinetics in the batch test were fast and equilibrium was obtained for all PFAS compounds within 24 h, the prescribed equilibration time. The same solubility was obtained for short-chain PFAS (PFBA, PFHxA, PFHpA, PFBS) in demineralized water and 1 mM CaCl2, whereas significantly lower solubility was often observed for long-chain PFAS in CaCl2 than in water, probably due to decreased charge repulsion between soil surfaces and PFAS compounds. In the up-flow percolation test, concentrations of short-chain PFAS in leachates decreased rapidly with increasing L/S, in contrast to long-chain PFAS, where concentrations decreased gradually or remained constant. Solid–solution partitioning coefficients (Kd), calculated from the data of the batch and percolation tests (1 mM CaCl2), were generally in agreement, although differing by more than three orders of magnitude between different PFAS compounds. Uncertainties and pitfalls when calculating Kd values from leaching test data are also explored.
Extractable organic fluorine (EOF) analysis is used to assess fluorinated organic content in, e.g., water and solid sample extracts. EOF content is often determined by combustion ion chromatography (CIC). However, contamination from inorganic fluoride (F-) in extracts risks overestimating actual EOF. Despite this known interference, a standardized and optimized methodology to mitigate such contamination remains lacking. In this study, we evaluated the presence of F- in EOF extracts and designed and validated a method for F- determination in small aliquots (∼250 μL) of complex aqueous and solvent matrices. The method is based on derivatization of F- to triphenylfluorosilane (TPSiF) and subsequent analysis with gas-chromatographic tandem mass spectrometry analysis (GC-MS/MS). Calibration was linear from 1 to 1000 μg L-1 (R2 > 0.99), and the limit of detection and the limit of quantification were 0.98 and 4.5 μg F- L-1, respectively. The relative standard deviation was below 7% across the calibrated range. A certified reference material (CRM River water) and F--spiked minced meat were used to assess F- recovery to 103 ± 3% (p = 0.10) and 95 ± 6% (p = 0.31) of certified/spiked concentrations. Analysis of sample extracts showed that (1) solid-phase extraction extracts of river water, (2) solvent extracts from aqueous-film-forming foam (AFFF)-impacted soil, and (3) extracts of a fish sample contained 29-49, 61 ± 4.7, and 17-90 μg F- L-1, respectively. F- accounted for 3-59% of the measured EOF, indicating a substantial overestimation. Therefore, the analysis and discount of F- in EOF extracts are essential for accurate EOF determination by CIC.
About Me
My primary research interest is in exploring the halogenated organic space in food and in the environment.
My primary research interest is in exploring the halogenated organic space in food and in the environment.