Joseph Borrello

Dr. Joseph Borrello

Sinai BioDesign, Icahn School of Medicine at Mount Sinai, New York, USA
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2018 in Additive Manufacturing
Verified
Journal Article
Closed access
Joseph BorrelloJoseph Borrello
Joseph Borrello
PNPhilip Nasser
Philip Nasser
JIJames Iatridis
James Iatridis
KCKevin D. Costa
Kevin D. Costa

17 November 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
BZBei Zhang
Bei Zhang
ASAlan C. Seifert
Alan C. Seifert
JKJoo‐Won Kim
Joo‐Won Kim
Joseph BorrelloJoseph Borrello
Joseph Borrello
JXJunqian Xu
Junqian Xu

4 January 2023 in Cancers
Verified
Journal Article
Open access
PDF file
ASAnirudh Sharma
Anirudh Sharma
AJAvesh Jangam
Avesh Jangam
JSJulian Low Yung Shen
Julian Low Yung Shen
AAAiman Ahmad
Aiman Ahmad
NANageshwar Arepally
Nageshwar Arepally
AAAnilchandra Attaluri
Anilchandra Attaluri
We present in vivo validation of an automated magnetic hyperthermia therapy (MHT) device that uses real-time temperature input measured at the target to control tissue heating. MHT is a thermal therapy that uses heat generated by magnetic materials exposed to an alternating magnetic field. For temperature monitoring, we integrated a commercial fiber optic temperature probe containing four gallium arsenide (GaAs) temperature sensors. The controller device used temperature from the sensors as input to manage power to the magnetic field applicator. We developed a robust, multi-objective, proportional-integral-derivative (PID) algorithm to control the target thermal dose by modulating power delivered to the magnetic field applicator. The magnetic field applicator was a 20 cm diameter Maxwell-type induction coil powered by a 120 kW induction heating power supply operating at 160 kHz. Finite element (FE) simulations were performed to determine values of the PID gain factors prior to verification and validation trials. Ex vivo verification and validation were conducted in gel phantoms and sectioned bovine liver, respectively. In vivo validation of the controller was achieved in a canine research subject following infusion of magnetic nanoparticles (MNPs) into the brain. In all cases, performance matched controller design criteria, while also achieving a thermal dose measured as cumulative equivalent minutes at 43 °C (CEM43) 60 ± 5 min within 30 min.

29 April 2017
Verified
Book Chapter
Closed access
PDF file
Joseph BorrelloJoseph Borrello
Joseph Borrello
PBPeter Backeris
Peter Backeris

22 November 2023 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
BRBenjamin Rodriguez
Benjamin Rodriguez
PCPeter Campbell
Peter Campbell
Joseph BorrelloJoseph Borrello
Joseph Borrello
IOIan Odland
Ian Odland
TWTyree Williams
Tyree Williams
CHConstantinos G. Hadjipanayis
Constantinos G. Hadjipanayis
High-grade gliomas (HGG) are the most common primary brain malignancy and continue to be associated with a dismal prognosis (median survival rate of 15–18 months) with standard of care therapy. Magnetic hyperthermia therapy (MHT) is an emerging intervention that leverages the ferromagnetic properties of magnetic iron-oxide nanoparticles (MIONPs) to target cancer cells that are otherwise left behind after resection. We report a novel port device to facilitate localization, delivery, and temperature measurement of MIONPs within a target lesion for MHT therapy. We conducted an in-depth literature and intellectual property review to define specifications of the conceived port device. After setting the design parameters, a thorough collaboration with neurological surgeons guided the iterative modeling process. A prototype was developed using Fusion 360 (Autodesk, San Rafael, CA) and printed on a Form 3 printer (Formlabs, Medford, MA) in Durable resin. The prototype was then tested in a phantom skull printed on a Pro-Jet 660Pro 3D printer (3D Systems, Rock Hill, SC) and a brain model based on mechanical and electrochemical properties of native brain tissue. This phantom underwent MHT heating tests using an alternating magnetic field (AMF) sequence based on current MHT workflow. Successful localization, delivery, and temperature measurement were demonstrated. The purpose of this study was twofold: first, to create and validate the procedural framework for a novel device, providing the groundwork for an upcoming comprehensive animal trial and second, to elucidate a cooperative approach between engineers and clinicians that propels advancements in medical innovation.

30 March 2021 in Journal of Clinical and Translational Science
Verified
Journal Article
Open access
PDF file
LFLayla Fattah
Layla Fattah
JGJanice Gabrilove
Janice Gabrilove
HOHolly Oemke
Holly Oemke
Joseph BorrelloJoseph Borrello
Joseph Borrello
TBTurner S Baker
Turner S Baker
ACAnthony Costa
Anthony Costa
IMPACT: Implement and evaluate a fellowship program to foster a new generation of entrepreneurial and collaboratively-minded team scientists, equipped with the knowledge and skills to innovate technology-based solutions for COVID-19 to advance human health OBJECTIVES/GOALS: Mount Sinai Targeted Healthcare Innovation Fellowship (THRIVE) is a 9-month program for participants from diverse professional backgrounds to develop HealthTech innovations related to COVID-19. The program is designed to provide an experiential team science platform for fellows to take an idea from concept to commercially viable innovation. METHODS/STUDY POPULATION: Following a competitive application process, 16 THRIVE fellows comprise four teams working collaboratively in an online forum with input from experts in the field. Success of the program will be evaluated by:assessing pre- and post- collaborative research orientation among THRIVE fellows using the ROI scale1using social network analysis (SNA) to investigate the social networks of THRIVE fellows to capture patterns of communication and collaboration related to innovation developmentexploring participant experiences of group formation, teamwork and collaboration related to innovation development using one-to-one semi-structured interviewdetermining team success in innovation development, measured by number of publications, funding awarded, provisional patents and viable products. RESULTS/ANTICIPATED RESULTS: Paired t-tests will determine whether collaborative orientation of THRIVE fellows changes pre- vs. post- program participation, indicating changes in attitude toward multidisciplinary team work. SNA will be used to describe structural patterns of communication that occur at individual and group levels. Network-level indices will provide insight into patterns of communication that exist in innovation development: degree centrality (number of connections per individual), betweenness centrality (number of bridges to others in a network), closeness centrality (closeness to others in a network). We will also test for associations between network characteristics and team success. DISCUSSION/SIGNIFICANCE OF FINDINGS: Understanding patterns of formal and informal relationships, interactions, and perceptions of the collaborative process among individuals in THRIVE teams will elucidate whether such a program can provide an effective forum for team science and innovation development related to COVID-19.