MRI has become an indispensable tool for brain volumetric studies, with the hippocampus an important region of interest. Automation of the MRI segmentation process has helped advance the field by facilitating the volumetric analysis of larger cohorts and more studies. FreeSurfer has emerged as the de facto standard tool for these analyses, but studies validating its output are all based on older versions. To characterize FreeSurfer's validity, we compare several versions of FreeSurfer software with traditional hand‐tracing. Using MRI images of 262 males and 402 females aged 38 to 84, we directly compare estimates of hippocampal volume from multiple versions of FreeSurfer, its hippocampal subfield routines, and our manual tracing protocol. We then use those estimates to assess asymmetry and atrophy, comparing performance of different estimators with each other and with brain atrophy measures. FreeSurfer consistently reports larger volumes than manual tracing. This difference is smaller in larger hippocampi or older people, with these biases weaker in version 6.0.0 than prior versions. All methods tested agree qualitatively on rightward asymmetry and increasing atrophy in older people. FreeSurfer saves time and money, and approximates the same atrophy measures as manual tracing, but it introduces biases that could require statistical adjustments in some studies.
Purpose: In this study, we examine whether an excitatory repetitive transcranial magnetic stimulation (rTMS) protocol called intermittent theta burst stimulation (iTBS) applied to the affected left hemisphere leads to changes in white matter fractional anisotropy (FA). Methods: Diffusion tensor imaging (DTI) data were collected in 8 aphasic stroke patients before and after 10 daily iTBS treatments. Alignment of structural and DTI data and derivation of diffusion index maps were performed using Analysis of Functional NeuroImages software followed by Tract-Based Spatial Statistics using FMRIB Software Library. Paired t-tests were performed to compare pre- to post-rTMS changes in FA. Results: There were significant (p < 0.001) left-hemispheric FA increases near the inferior and superior frontal gyri and anterior corpus callosum. FA also increased in the right midbrain and bilaterally near temporal, parietal and posterior cingulate regions. FA decreased bilaterally near the fusiform gyrus and in left cerebellum. Conclusions: Overall, left-hemispheric regions that showed increased FA corresponded to areas previously shown to have increases in fMRI language activation after iTBS. The increased white matter integrity near the stimulation sites may reflect improvements in cortical function mediated by excitatory rTMS through its ability to facilitate synaptic connections.
Institutional review board approval, with waived consent, was obtained to develop a spine-labeling algorithm with retrospectively obtained deidentified HIPAA-compliant data. An automated magnetic resonance (MR) imaging technique to rapidly survey the entire spine and provide definitive numbering of disks and vertebrae was compared with neuroradiologist assignments in 50 cases. Contiguous two-station sagittal fast gradient-recalled-echo sequences with 35-cm fields of view (FOVs) were preprogrammed for full cervical, thoracic, and lumbar spine coverage (combined 70-cm FOV, seven sections, 15 mm left of to 15 mm right of midline, 4-mm section thickness, 1-mm intersection gap, 512 x 352 matrix, 58/2.0 [repetition time msec/echo time msec], 30 degrees flip angle, 15.6-kHz bandwidth, 42-second acquisition time). In all cases, the neuroradiologist could visualize and definitively number all cervical, thoracic, and lumbar levels on automated spine survey iterative scan technique localizer studies. Automated disk-vertebra detection and numbering were concordant with neuroradiologist assignments in all cases. The entire spine can be surveyed with subminute, submillimeter in-plane resolution MR imaging. Cervical, thoracic, and lumbar vertebrae and disks can be readily identified and definitively numbered by means of visual inspection or semiautomated computer algorithm.