Juan C Colado

Dr. Juan C Colado

Department of Physical Education and Sports., University of Valencia, Valencia, Spain
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2008 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
Juan C ColadoJuan C Colado
Juan C Colado
NTN Travis Triplett
N Travis Triplett
This study was designed to determine whether different effects on functional capacity and body composition were produced by using different devices (elastic bands (EBs) versus weight machines (WMs)) with the same resistance training program. Forty-five healthy sedentary middle-aged women volunteers were chosen and randomly assigned to 1 of 3 groups: 21 subjects trained using EBs (EBG), 14 in trained using WMs (WMG), and 10 were controls (CG). Both exercise groups trained with a periodized muscular endurance program twice a week for 10 weeks, with a total of 6 exercises per session for the major muscle groups. Exercise intensity was equalized by jointly monitoring the same targeted number of repetitions (TNRs) and rate of perceived exertion in active muscles (RPE-AM). Functional capacity was assessed by using knee push-up (KPU) and 60-second squat (S) tests. Body composition was measured using an 8-polar bioelectrical impedance analyzer. The results for both the EBG and WMG show a decrease in fat mass (p = 0.05 and p < 0.01, respectively) and an increase in both the fat-free mass (p < 0.05 and p < 0.01, respectively) and the number of repetitions in the KPU (p < 0.05 and p < 0.01, respectively) and S tests (p < 0.01 in both). None of the variables measured for the CG varied significantly. It can be concluded that, independently of the device used, the combined monitoring of TNRs and RPE-AM can be a valid tool for controlling the resistance exercise intensity and can lead to healthy adaptations. EBs can thus offer significant physiological benefits that are comparable to those obtained from WMs in the early phase of strength training of sedentary middle-aged women.

1 November 2012 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
Juan C ColadoJuan C Colado
Juan C Colado
XGXavier Garcia-Masso
Xavier Garcia-Masso
TTTravis N. Triplett
Travis N. Triplett
JFJorge Flandez
Jorge Flandez
SBSebastien Borreani
Sebastien Borreani
VTVictor Tella
Victor Tella
The concurrent validity of the OMNI-Resistance Exercise Scale (OMNI-RES) of perceived exertion for use with elastic bands was studied during isotonic resistance exercises. Twenty healthy, physically active subjects completed both familiarization and testing sessions. The criterion variables were myoelectric activity, recorded by electromyography, and heart rate, recorded by a heart rate monitor. The subjects performed 2 separate sets of 15 repetitions in each of the 2 testing sessions and for each of the exercises applied (i.e., frontal and lateral raises). One set was carried out with the separation between the hands gripping the elastic band allowing that 15 repetition maximum to be performed in the selected exercise, whereas the other set was carried out with the separation between hands at +50% of the previous grip. The perceived exertion rating for the active muscles and for the overall body, muscular activity, and heart rate were measured during the final repetition of each set. The results showed significant differences (p ≤ 0.001) in myoelectric activity, heart rate, and OMNI-RES scores between the low- and high-intensity sets and the intraclass correlation coefficient was 0.72-0.76. So it can be concluded that the OMNI-RES can be used for monitoring the intensity of exercises when elastic bands are used. This would allow the training stimulus dosage to be precisely controlled in both the session in progress and between different sessions, and allowing to differentiate between different levels of intensity according to the physical aptitudes and special physiological needs of the subjects.

10 February 2009 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
Juan C ColadoJuan C Colado
Juan C Colado
NTN. Travis Triplett
N. Travis Triplett
VTVictor Tella
Victor Tella
PSPedro Saucedo
Pedro Saucedo
JAJosé Abellán
José Abellán

11 August 2010 in International Journal of Sports Medicine
Verified
Journal Article
Closed access
Juan C ColadoJuan C Colado
Juan C Colado
XGX. Garcia-Masso
X. Garcia-Masso
MPM. Pellicer
M. Pellicer
YAY. Alakhdar
Y. Alakhdar
JBJ. Benavent
J. Benavent
Ruth Cabeza-RuizRuth Cabeza-Ruiz
Ruth Cabeza-Ruiz
The aim of this study was to assess effects of a short-term resistance program on strength in fit young women using weight machines/free weights or elastic tubing. 42 physically fit women (21.79±0.7 years) were randomly assigned to the following groups: (i) the Thera-Band® Exercise Station Group (TBG); (ii) the weight machines/free weights group (MFWG); or (iii) the control group (CG). Each experimental group performed the same periodised training program that lasted for 8 weeks, with 2–4 sessions per week and 3–4 sets of 8–15 submaximal reps. A load cell (Isocontrol; ATEmicro, Madrid, Spain) was used to test the evolution of the Maximum Isometric Voluntary Contraction (MIVC) in 3 different exercises: Vertical Rowing (VR), Squat (S) and Back Extension (BE). A mixed model MANOVA [group (CG, TBG, MFWG) x testing time (pre-test, post-test)] was applied to determine the effect of the different resistance training devices on strength. The only groups to improve their MIVC (p<0.005) were TBG and MFWG, respectively: VR 19.87% and 19.76%; S 14.07 and 28.88; BE 14.41% and 14.00%. These results indicate that resistance training using elastic tubing or weight machines/free weights have equivalent improvements in isometric force in short-term programs applied in fit young women.

1 March 2018 in Experimental Gerontology
Verified
Journal Article
Closed access
Juan C ColadoJuan C Colado
Juan C Colado
FPFelipa M. Pedrosa
Felipa M. Pedrosa
AJAlvaro Juesas
Alvaro Juesas
PBPedro Gargallo Bayo
Pedro Gargallo Bayo
JCJuan José Carrasco
Juan José Carrasco
Fernando NaclerioFernando Naclerio
Fernando Naclerio

1 October 2010 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
Iván Chulvi-MedranoIván Chulvi-Medrano
Iván Chulvi-Medrano
XGXavier García-Massó
Xavier García-Massó
Juan C ColadoJuan C Colado
Juan C Colado
CPCarlos Pablos
Carlos Pablos
JMJoao Alves de Moraes
Joao Alves de Moraes
MFMaria A Fuster
Maria A Fuster
Uscle activity between deadlifts carried out in a standard way and with different instability devices (Bosu and T-Bow). Deadlifts involve the performance of muscle activities with dynamic and isometric characteristics. Thirty-one subjects participated voluntarily in the study. Initially, they performed an isometric test for 5 seconds in each condition. After that, they performed a set of 5 repetitions with 70% of the maximum isometric force obtained in each one of the previously evaluated conditions. During the isometric tests, records of electromyographic activity and force production were obtained, whereas during the dynamic tests, only the electromyographic activity was registered. The subjects produced more force and muscle activity on the stable surface than under the other conditions during the isometric test (p < 0.05), and the same differences in muscle activity were observed during the dynamic test (p < 0.05). These data show that the performance of deadlifts under stable conditions favors a higher production of maximum strength and muscle activity. Therefore, we conclude that the use of instability devices in deadlift training does not increase performance, nor does it provide greater activation of the paraspinal muscles, leading us to question their value in the performance of other types of exercises....