Jurgita Žižienė

Mrs. Jurgita Žižienė

Vilnius Gediminas Technical University, Vilnius, Vilniaus Miestas, Lithuania
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Kristina DaunoravičienėKristina Daunoravičienė
Kristina Daunoravičienė
JŽJurgita Žižienė
Jurgita Žižienė
Jolanta PaukJolanta Pauk
Jolanta Pauk
GJGiedre Juskeniene
Giedre Juskeniene
JRJuozas Raistenskis
Juozas Raistenskis
The purpose of this study was to examine the changes in muscular activity between the left and right lower legs during gait in healthy children throughout temporal parameters of EMG and symmetry index (SI). A total of 17 healthy children (age: 8.06 ± 1.92 years) participated in this study. Five muscles on both legs were examined via the Vicon 8-camera motion analysis system synchronized with a Trigno EMG Wireless system and a Bertec force plate; onset–offset intervals were analyzed. The highest occurrence frequency of the primary activation modality was found in the stance phase. In the swing phase, onset–offset showed only a few meaningful signs of side asymmetry. The knee flexors demonstrated significant differences between the sides (p < 0.05) in terms of onset–offset intervals: biceps femoris in stance, single support, and pre-swing phases, with SI values = −6.45%, −14.29%, and −17.14%, respectively; semitendinosus in single support phase, with SI = −12.90%; lateral gastrocnemius in swing phase, with SI = −13.33%; and medial gastrocnemius in stance and single support phases, with SI = −13.33% and −23.53%, respectively. The study outcomes supply information about intra-subject variability, which is very important in follow-up examinations and comparison with other target groups of children.

24 June 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JŽJurgita Žižienė
Jurgita Žižienė
KDKristina Daunoraviciene
Kristina Daunoraviciene
GJGiedre Juskeniene
Giedre Juskeniene
JRJuozas Raistenskis
Juozas Raistenskis
The purpose of this study is to compare differences between kinematic parameters of pediatric gait obtained by direct kinematics (DK) (Plug-in-Gait) and inverse kinematics (IK) (AnyBody) models. Seventeen healthy children participated in this study. Both lower extremities were examined using a Vicon 8-camera motion capture system and a force plate. Angles of the hip, knee, and ankle joints were obtained based on DK and IK models, and ranges of motion (ROMs) were identified from them. The standard error of measurement, root-mean-squared error, correlationr, and magnitude-phase (MP) metrics were calculated to compare differences between the models’ outcomes. The determined standard error of measurement between ROMs from the DK and IK models ranged from 0.34° to 0.58°. A significant difference was found in the ROMs with the exception of the left hip’s internal/external rotation. The mean RMSE of all joints’ amplitudes exceeded the clinical significance limit and was 13.6 ± 4.0°. The best curve angles matching nature were found in the sagittal plane, whererwas 0.79 to 0.83 and MP metrics were 0.05 to 0.30. The kinematic parameters of pediatric gait obtained by IK and DK differ significantly. Preferably, all of the results obtained by DK must be validated/verified by IK, in order to achieve a more accurate functional assessment of the individual. Furthermore, the use of IK expands the capabilities of gait analysis and allows for kinetic characterisation.

17 January 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VAVytautas Abromavicius
Vytautas Abromavicius
EGErvinas Gisleris
Ervinas Gisleris
Kristina DaunoravičienėKristina Daunoravičienė
Kristina Daunoravičienė
JŽJurgita Žižienė
Jurgita Žižienė
Artūras SerackisArtūras Serackis
Artūras Serackis
RMRytis Maskeliūnas
Rytis Maskeliūnas
The objective of this work is to develop a method for tracking human skeletal movements by integrating data from two synchronized video streams. To achieve this, two datasets were created, each consisting of four different rehabilitation exercise videos featuring various individuals in diverse environments and wearing different clothing. The prediction model is employed to create a dual-image stream system that enables the tracking of joint positions even when a joint is obscured in one of the streams. This system also mitigates depth coordinate errors by using data from both video streams. The final implementation successfully corrects the positions of the right elbow and wrist joints, though some depth error persists in the left hand. The results demonstrate that adding a second video camera, rotated 90° and aimed at the subject, can compensate for depth prediction inaccuracies, reducing errors by up to 0.4 m. By using a dual-camera setup and fusing the predicted human skeletal models, it is possible to construct a complete human model even when one camera does not capture all body parts and to refine depth coordinates through error correction using a linear regression model.

14 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Kristina DaunoravičienėKristina Daunoravičienė
Kristina Daunoravičienė
JŽJurgita Žižienė
Jurgita Žižienė
(1) Background: Significant advances in digital modelling worldwide have been attributed to the practical application of digital musculoskeletal (MS) models in clinical practice. However, the vast majority of MS models are designed to assess adults’ mobility, and the range suitable for children is very limited. (2) Methods: Seventeen healthy and 4 cerebral palsy (CP) children were recruited for the gait measurements. Surface electromyography (EMG) and ground reaction forces (GRFs) were acquired simultaneously. The MS model of the adult was adapted to the child and simulated in AnyBody. The differences between measured and MS model-estimated GRFs and muscle activations were evaluated using the following methods: the root-mean-square error (RMSE); the Pearson coefficient r; statistical parametric mapping (SPM) analysis; the coincidence of muscle activity. (3) Results: For muscle activity, the RMSE ranged from 10.4% to 35.3%, the mismatch varied between 16.4% and 30.5%, and the coincidence ranged between 50.7% and 68.4%; the obtained strong or very strong correlations between the measured and model-calculated GRFs, with RMSE values in the y and z axes ranged from 7.1% to 17.5%. (4) Conclusions: Child-adapted MS model calculated muscle activations and GRFs with sufficient accuracy, so it is suitable for practical use in both healthy children and children with limited mobility.

16 November 2023 in Technology and Health Care
Verified
Journal Article
Closed access
PDF file
KDKristina Daunoraviciene
Kristina Daunoraviciene
JPJolanta Pauk
Jolanta Pauk
JŽJurgita Žižienė
Jurgita Žižienė
VBVaida Belickiene
Vaida Belickiene
JRJuozas Raistenskis
Juozas Raistenskis
BACKGROUND: Healthy children’s gait support patterns play a critical role in their development and overall well-being. Therefore, in order to develop a correct gait, it is necessary to constantly update knowledge. OBJECTIVE: To identify differences in gait support among children in neighbouring countries. METHODS: 44 healthy children from Poland and Lithuania (4–11 years old) participated in the study. The spatiotemporal and plantar pressure parameters of 88 neutrally aligned feet were analysed and compared. RESULTS: Statistically significant differences between stance, single-limb support, double support, swing duration, cadence, and velocity, max. force and pressure in the forefoot, as well as in the times of occurrence of max. forces in all three zones. Defined that age is related (p< 0.05) to cadence (R= 0.32), swing phase (R= 0.53), max. force under the midfoot (R= 0.35) and the heel (R= 0.47), max. pressure under the forefoot (R=-0.52), midfoot (R=-0.63) and heel (R=-0.47). CONCLUSION: The results can help caregivers, as well as clinicians and researchers, understand how gait mechanics change with development and the growth course of the children of that country. Also, the results are important for the analysis and comparison of children’s gait, as control reference data from the same country.

22 August 2024 in Machines
Verified
Journal Article
Open access
PDF file
KLKarina Lenkevitciute
Karina Lenkevitciute
JŽJurgita Žižienė
Jurgita Žižienė
Kristina DaunoravičienėKristina Daunoravičienė
Kristina Daunoravičienė
The aim of this study was to determine the most appropriate advanced methods for distinguishing the gait of healthy children (CO) from the gait of children with cerebral palsy (CP) based on electromyography (EMG) parameters and coactivations. An EMG database of 22 children (aged 4–11 years) was used in this study, which included 17 subjects in the CO group and 5 subjects in the CP group. EMG time parameters were calculated for the biceps femoris (BF) and semitendinosus (SE) muscles and coactivations for the rectus femoris (RF)/BF and RF/SE muscle pairs. To obtain a more accurate classification result, data augmentation was performed, and three classification algorithms were used: support vector machine (SVM), k-nearest neighbors (KNNs), and decision tree (DT). The accuracy of the root-mean-square (RMS) parameter and KNN algorithm was 95%, the precision was 94%, the sensitivity was 90%, the F1 score was 92%, and the area under the curve (AUC) score was 98%. The highest classification accuracy based on coactivations was achieved using the KNN algorithm (91–95%). It was determined that the KNN algorithm is the most effective, and muscle coactivation can be used as a reliable parameter in gait classification tasks.