Chunjoo Park

Prof. Chunjoo Park


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2022 in Practical Radiation Oncology
Verified
Journal Article
Closed access
HMHoward E. Morgan
Howard E. Morgan
KWKai Wang
Kai Wang
YYYulong Yan
Yulong Yan
NDNeil Desai
Neil Desai
RHRaquibul Hannan
Raquibul Hannan
AGAurelie Garant
Aurelie Garant

13 August 2023 in Cancers
Verified
Journal Article
Open access
PDF file
XLXiaoying Liang
Xiaoying Liang
Chris BeltranChris Beltran
Chris Beltran
CLChunbo Liu
Chunbo Liu
CPChunjoo Park
Chunjoo Park
BLBo Lu
Bo Lu
Keith FurutaniKeith Furutani
Keith Furutani
Pencil beam scanning delivered with continuous scanning has several advantages over conventional discrete spot scanning. Such advantages include improved beam delivery efficiency and reduced beam delivery time. However, a move dose is delivered between consecutive spots with continuous scanning, and current treatment planning systems do not take this into account. Therefore, continuous scanning and discrete spot plans have an inherent dose discrepancy. Using the operating parameters of the state-of-the-art particle therapy system, we conducted a proof-of-concept study in which we systematically generated 28 plans for cubic targets with different combinations of plan parameters and simulated the dose discrepancies between continuous scanning and a planned one. A nomograph to guide the selection of plan parameters was developed to reduce the dose discrepancy. The effectiveness of the nomograph was evaluated with two clinical cases (one prostate and one liver). Plans with parameters guided by the nomograph decreased dose discrepancy than those used standard plan parameters. Specifically, the 2%/2 mm gamma passing rate increased from 96.3% to 100% for the prostate case and from 97.8% to 99.7% for the liver case. The CTV DVH root mean square error decreased from 2.2% to 0.2% for the prostate case and from 1.8% to 0.9% for the liver case. The decreased dose discrepancy may allow the relaxing of the delivery constraint for some cases, leading to greater benefits in continuous scanning. Further investigation is warranted.

15 September 2024 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
BCByongsu Choi
Byongsu Choi
Chris BeltranChris Beltran
Chris Beltran
SYSang Kyun Yoo
Sang Kyun Yoo
NKNa Hye Kwon
Na Hye Kwon
JKJin Sung Kim
Jin Sung Kim
CPChunjoo Park
Chunjoo Park
Adaptive radiotherapy (ART) workflows are increasingly adopted to achieve dose escalation and tissue sparing under dynamic anatomical conditions. However, recontouring and time constraints hinder the implementation of real-time ART workflows. Various auto-segmentation methods, including deformable image registration, atlas-based segmentation, and deep learning-based segmentation (DLS), have been developed to address these challenges. Despite the potential of DLS methods, clinical implementation remains difficult due to the need for large, high-quality datasets to ensure model generalizability. This study introduces an InterVision framework for segmentation. The InterVision framework can interpolate or create intermediate visuals between existing images to generate specific patient characteristics. The InterVision model is trained in two steps: (1) generating a general model using the dataset, and (2) tuning the general model using the dataset generated from the InterVision framework. The InterVision framework generates intermediate images between existing patient image slides using deformable vectors, effectively capturing unique patient characteristics. By creating a more comprehensive dataset that reflects these individual characteristics, the InterVision model demonstrates the ability to produce more accurate contours compared to general models. Models are evaluated using the volumetric dice similarity coefficient (VDSC) and the Hausdorff distance 95% (HD95%) for 18 structures in 20 test patients. As a result, the Dice score was 0.81 ± 0.05 for the general model, 0.82 ± 0.04 for the general fine-tuning model, and 0.85 ± 0.03 for the InterVision model. The Hausdorff distance was 3.06 ± 1.13 for the general model, 2.81 ± 0.77 for the general fine-tuning model, and 2.52 ± 0.50 for the InterVision model. The InterVision model showed the best performance compared to the general model. The InterVision framework presents a versatile approach adaptable to various tasks where prior information is accessible, such as in ART settings. This capability is particularly valuable for accurately predicting complex organs and targets that pose challenges for traditional deep learning algorithms.