Jaroslav Zuda

Dr. Jaroslav Zuda

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2011 in Measurement Science and Technology
Verified
Journal Article
Closed access
ACAnna Campbellová
Anna Campbellová
MVMiroslav Valtr
Miroslav Valtr
JZJaroslav Zuda
Jaroslav Zuda
PKPetr Klapetek
Petr Klapetek

22 March 2022 in Measurement Science and Technology
Verified
Journal Article
Open access
JZJaroslav Zuda
Jaroslav Zuda
The determination of the volumes of mass standards is key to the precise determination of their masses, due to the effect of the air buoyancy force. The buoyancy force can either be reduced by mass determination at low pressure or enlarged for a determination of the apparent mass using a vessel filled with liquid. The standard method for the volume calibration of weights is comparison in liquid, as described in the document OIML R111. This report presents the results of calibrating the volumes of stainless-steel mass standards with a nominal mass of 1 kg at low pressure and in a liquid. The authors showed that both methods produced comparable results with maximum differences of 0.002 cm3 when adjusted for a standard temperature of 20 °C. The typical uncertainty in the volumes given by both methods is 0.002 cm3. A major source of uncertainty is the volume of the reference weight. The authors conclude that both methods produce consistent results, so that the method of volume calibration at low pressure can be used instead of hydrostatic weighing. The advantage of this approach is that both the masses and volumes of the weights are measured using the same mass comparator, which requires less manipulation. This study will help to establish the procedures for the dissemination and transfer of the mass unit from vacuum to ambient conditions in the institute of the author.

1 January 2013 in Measurement
Verified
Journal Article
Closed access
DPD. Pražák
D. Pražák
JZJaroslav Zuda
Jaroslav Zuda
JTJ. Tesař
J. Tesař
LPL. Peksa
L. Peksa
MVM. Vičar
M. Vičar

1 November 2017 in Applied Surface Science
Verified
Journal Article
Closed access
Petr KlenovskýPetr Klenovský
Petr Klenovský
JZJaroslav Zuda
Jaroslav Zuda
PKPetr Klapetek
Petr Klapetek
JHJosef Humlíček
Josef Humlíček

1 January 2020 in Metrologia
Verified
Journal Article
Closed access
SAS Alisic
S Alisic
BGB Gutfeldt
B Gutfeldt
FBF Beaudoux
F Beaudoux
MBM Bezjak
M Bezjak
MCM Coenegrachts
M Coenegrachts
SASaud M AlQarni
Saud M AlQarni
In order to demonstrate the equivalence in calibration of mass standards among National Metrology Institutes (NMIs) of EURAMET this key comparison (KC) on 1 kg stainless steel mass standards has been carried out under the auspices of EURAMET. The comparison was undertaken with reference to the International Prototype Kilogram (IPK) as the definition of the unit of mass. The overall result shows good consistency among the participants. Main text To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ . The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

1 January 2019 in Metrologia
Verified
Journal Article
Closed access
TSTamilla Shabiyeva
Tamilla Shabiyeva
JZJaroslav Zuda
Jaroslav Zuda
This report describes the results of bilateral supplementary comparison COOMET.M.M-S4 (also known as COOMET 722/AZ/17). The comparison measurements between the two participants Czech Metrology Institute (CMI) (pilot laboratory) and Azerbaijan Institute of Metrology (AzMI) were started in December 2016 and finished in February 2017. The transfer standards were OIML Class E2 standard weights with nominal mass values of 5 kg, 500 g, 20 g, 2 g and 100 mg. Agreement between the two participants is good. Main text To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ . The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).