Ahmed Yahia Kallel

Dr. Ahmed Yahia Kallel

TU Chemnitz
orcid
Postdoctoral researcher and group leader at the Technische U...

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

24 March 2022 in Measurement
Verified
Journal Article
Closed access
OKOlfa Kanoun
Olfa Kanoun
AKAhmed Yahia Kallel
Ahmed Yahia Kallel
AFAhmed Fendri
Ahmed Fendri

16 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AKAhmed Yahia Kallel
Ahmed Yahia Kallel
VPViktor Petrychenko
Viktor Petrychenko
Olfa KanounOlfa Kanoun
Olfa Kanoun
Several studies show that impedance spectroscopy is a suitable method for online battery diagnosis and State-of-Health (SoH) estimation. However, the most common method is to model the acquired impedance spectrum with equivalent circuits and focus on the most sensitive parameters, namely the charge-transfer resistance. This paper introduces first a detailed model of a battery cell, which is then simplified and adapted to the observable spectrum behavior. Based on the physical meaning of the model parameters, we propose a novel approach for SoH assessment combining parameters of the impedance spectrum by building the ratio of the solid electrolyte interphase (SEI) resistance to the total resistance of SEI and the charge transfer. This ratio characterizes the charge-transfer efficiency at the electrodes’ surfaces and should decrease systematically with SoH. Four different cells of the same type were cycled 400 times for the method validation, and impedance spectroscopy was performed at every 50th cycle. The results show a systematic correlation between the proposed ratio and the number of cycles on individual cell parameters, which build the basis of a novel online method of SoH assessment.

21 May 2021 in Measurement Science and Technology
Verified
Journal Article
Open access
AKAhmed Yahia Kallel
Ahmed Yahia Kallel
DBD Bouchaala
D Bouchaala
Olfa KanounOlfa Kanoun
Olfa Kanoun
Wideband excitation signals are essential in bioimpedance spectroscopy for measurements in a time ensuring a quasi-stable measurement condition. In particular, for wearable biomedical systems, due to limited system resources, several aspects regarding measurement time, crest factor, slew rate requirements, frequency distribution, amplitude spectrum, and energy efficiency need to be thoroughly investigated. In this paper, we present an investigation of excitation signals, which includes not only the theoretical aspects but also aspects of real implementation on microcontroller-based systems. At a fixed number of samples and sampling rate, we investigate the implementability of signal frequencies and the resulting spectral efficiency. We focus on sources of signal distortion due to timer and amplitude deviations. The results show that for 4096 samples and a sampling frequency of 1 MHz, wideband signals are 2.76 times faster than a stepped frequency sweep. The multisine signal provides a better energy efficiency and has a lower slew rate requirement on hardware (around 0.3 V µs−1), but has a relatively high crest factor, even after optimization. An exemplary investigation of the distortion of the time/frequency and amplitudes following implementation on a standard industrial advanced RISC machines microcontroller has shown that a sampling rate compensation is required to overcome timer inaccuracies. Furthermore, non-return-to-zero binary signals are more sensitive to distortion due to hardware-related issues and have a lower signal-to-distortion-and-noise (SINAD) ratio than 24 dB, which is lower than the multisine signal, having a SINAD of 31 dB.

3 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
BABilel Ben Atitallah
Bilel Ben Atitallah
AKAhmed Yahia Kallel
Ahmed Yahia Kallel
DBDhouha Bouchaala
Dhouha Bouchaala
NDNabil Derbel
Nabil Derbel
Olfa KanounOlfa Kanoun
Olfa Kanoun
Bioimpedance spectroscopy (BIS) is an advanced measurement method for providing information on impedance changes at several frequencies by injecting a low current into a device under test and analyzing the response voltage. Several methods have been elaborated for BIS measurement, calculating impedance with a gain phase detector (GPD), IQ demodulation, and fast Fourier transform (FFT). Although the measurement method has a big influence on the measurement system performance, a systematical comparative study has not been performed yet. In this paper, we compare them based on simulations and experimental studies. To maintain similar conditions in the implementation of all methods, we use the same signal generator followed by a voltage-controlled current source (VCCS) as a signal generator. For performance analysis, three DUTs have been designed to imitate the typical behavior of biological tissues. A laboratory impedance analyzer is used as a reference. The comparison addresses magnitude measurement accuracy, phase measurement accuracy, signal processing, hardware complexity, and power consumption. The result shows that the FFT-based system excels with high accuracy for amplitude and phase measurement while providing the lowest hardware complexity, and power consumption, but it needs a much higher software complexity.

7 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AKAhmed Yahia Kallel
Ahmed Yahia Kallel
ZHZheng Hu
Zheng Hu
Olfa KanounOlfa Kanoun
Olfa Kanoun
For embedded impedance spectroscopy, a suitable method for analyzing AC signals needs to be carefully chosen to overcome limited processing capability and memory availability. This paper compares various methods, including the fast Fourier transform (FFT), the FFT with barycenter correction, the FFT with windowing, the Goertzel filter, the discrete-time Fourier transform (DTFT), and sine fitting using linear or nonlinear least squares, and cross-correlation, for analyzing AC signals in terms of speed, memory requirements, amplitude measurement accuracy, and phase measurement accuracy. These methods are implemented in reference systems with and without hardware acceleration for validation. The investigation results show that the Goertzel algorithm has the best overall performance when hardware acceleration is excluded or in the case of memory constraints. In implementations with hardware acceleration, the FFT with barycentre correction stands out. The linear sine fitting method provides the most accurate amplitude and phase determinations at the expense of speed and memory requirements.