Large-scale serosurveillance of severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) will only be possible if serological tests are sufficiently reliable, rapid and affordable. Many assays are either labour-intensive and require specialised facilities (e.g. virus neutralization assays), or are expensive with suboptimal specificity (e.g. commercial ELISAs and RDTs). Bead-based assays offer a cost-effective alternative and allow for multiplexing to test for antibodies against multiple antigens and against other pathogens. Here, we compare the performance of spike (S) and nucleocapsid (NP) antigens for the detection of SARS-CoV-2 specific IgG, IgM and IgA antibodies in a panel of sera that includes recent (up to six weeks after symptom onset, severe n = 44; and mild cases n = 52) and old infections (five months after symptom onset, mild n = 104), using a Luminex-bead based assay and comparison to a virus neutralization test. While we show that neutralizing antibody levels are significantly lower in mild than in severe cases, we demonstrate that a combination of the recombinant nucleocapsid protein (NP) and receptor-binding domain (RBD) results in highly specific (99 %) IgG antibody detection five months after infection in 96 % of cases. Although most severe Covid-19 cases developed a clear IgM and IgA response, titers fell below the detection threshold in more than 20 % of mild cases in our bead-based assay. In conclusion, our data supports the use of RBD and NP for the development of SARS-CoV-2 serological IgG bead-based assays.
Serological markers for exposure to different Plasmodium species have recently been used in multiplex immunoassays based on the Luminex technology. However, interpretation of the assay results requires consideration of the half-life of specific antibodies against these markers. Therefore, the aim of the present study was to document the half-life of malaria specific serological makers, as well as assessing the sensitivity of these markers to pick up recent changes in malaria exposure. A recently developed multiplex immunoassay was used to measure the intensity of antibody (Ab) responses against 19 different Plasmodium specific antigens, covering different human malaria parasites and two vector saliva antigens. Therefore, 8439 blood samples from five cross-sectional surveys in Ratanakiri, Cambodia, were analysed. These involve a random selection from two selected surveys, and an additional set of blood samples of individuals that were randomly re-sampled three, four or five times. A generalized estimating equation model and linear regression models were fitted on log transformed antibody intensity data. Results showed that most (17/21) Ab-responses are higher in PCR positive than PCR negative individuals. Furthermore, these antibody-responses follow the same upward trend within each age group. Estimation of the half-lives showed differences between serological markers that reflect short- (seasonal) and long-term (year round) transmission trends. Ab levels declined significantly together with a decrease of PCR prevalence in a group of malaria endemic villages. For Plasmodium falciparum, antibodies against LSA3.RE, GLURP and Pf.GLURP.R2 are most likely to be a reflexion of recent (range from 6 to 8 months) exposure in the Mekong Subregion. PvEBP is the only Plasmodium vivax Ag responding reasonably well, in spite of an estimated Ab half-life of more than 1 year. The use of Ab intensity data rather dichotomizing the continuous Ab-titre data (positive vs negative) will lead to an improved approach for serological surveillance.
Epidemiological surveillance is a key activity in malaria control and elimination in low-transmission and pre-elimination settings. Hence, sensitive tools for estimating malaria force of infection are crucial. Serological markers might provide additional information in estimating force of infection in low-endemic areas along with classical parasite detection methods. Serological markers can be used to estimate recent, past or present malaria exposure, depending on the used markers and their half-life. An assay based on 14 Plasmodium-specific peptides, one peptide specific for Anopheles gambiae saliva protein and five Plasmodium-specific recombinant proteins was developed for the MAGPIX system, assessed for its performance, and applied on blood spots from 2000 individuals collected in the Ratanakiri Province, Cambodia. A significant correlation for the use of 1000 and 2000 beads/antigen/well as well as for the monoplex versus multiplex assay was observed for all antigens (p < 0.05). For the majority of antigens, antigen-coupled beads were stable for at least 2 months. The assay was very reproducible with limited intercoupling, interplate and intraplate variability (mean RSD <15 %). Estimating seroconversion and seroreversion per antigen using reversible catalytic models and models allowing two seroconversion rates showed higher seroconversion rates in adults. The multiplex bead-based immunoassay was successfully implemented and analysis of field blood samples shows that changes detected in force of malaria infection vary according to the serological markers used. Multivariate analysis of the antibody responses and insights into the half-life of antibodies are crucial for improving the interpretation of these results and for identifying the most useful serological markers of past and recent malaria infection.
Malaria transmission is highly heterogeneous, especially in low endemic countries, such as Cambodia. This results in geographical clusters of residual transmission in the dry, low transmission season, which can fuel the transmission to wider areas or populations during the wet season. A better understanding of spatial clustering of malaria can lead to a more efficient, targeted strategy to reduce malaria transmission. This study aims to evaluate the potential of the use of serological markers to define spatial patterns in malaria exposure. Blood samples collected in a community-based randomized trial performed in 98 high endemic communities in Ratanakiri province, north-eastern Cambodia, were screened with a multiplex serological assay for five serological markers (three Plasmodium falciparum and two Plasmodium vivax). The antibody half-lives range from approximately six months until more than two years. Geographical heterogeneity in malaria transmission was examined using a spatial scan statistic on serology, PCR prevalence and malaria incidence rate data. Furthermore, to identify behavioural patterns or intrinsic factors associated with malaria exposure (antibody levels), risk factor analyses were performed by using multivariable random effect logistic regression models. The serological outcomes were then compared to PCR prevalence and malaria incidence data. A total of 6502 samples from two surveys were screened in an area where the average parasite prevalence estimated by PCR among the selected villages is 3.4 %. High-risk malaria pockets were observed adjacent to the ‘Tonle San River’ and neighbouring Vietnam for all three sets of data (serology, PCR prevalence and malaria incidence rates). The main risk factors for all P. falciparum antigens and P. vivax MSP1.19 are age, ethnicity and staying overnight at the plot hut. It is possible to identify similar malaria pockets of higher malaria transmission together with the potential risk factors by using serology instead of PCR prevalence or malaria incidence data. In north-eastern Cambodia, the serological markers show that malaria transmission occurs mainly in adults staying overnight in plot huts in the field. Pf.GLURP.R2 showed a shrinking pocket of malaria transmission over time, and Pf.MSP1.19, CSP, PvAMA1 were also informative for current infection to a lesser extent. Therefore, serology could contribute in future research. However, further in-depth research in selecting the best combination of antigens is required.
Lyme borreliosis (LB) is not notifiable in many European countries, and accurate data on the incidence are often lacking. This study aimed to determine the seroprevalence of Borrelia burgdorferi sensu lato (s.l.)-specific antibodies in the general population of The Netherlands, and to determine risk factors associated with seropositivity. Sera and questionnaires were obtained from participants (n = 5592, aged 0–88 years) enrolled in a nationwide serosurveillance study. The sera were tested for B. burgdorferi s.l.-specific IgM and IgG antibodies using ELISA and immunoblot. Seroprevalence was estimated controlling for the survey design. Risk factors for seropositivity were analyzed using a generalized linear mixed-effect model. In 2016/2017, the seroprevalence in The Netherlands was 4.4% (95% CI 3.5–5.2). Estimates were higher in men (5.7% [95% CI 4.4–7.2]) than in women (3.1% [95% CI 2.0–4.0]), and increased with age from 2.6% (95% CI 1.4–4.4) in children to 7.7% (95% CI 5.9–7.9) in 60- to 88-year-olds. The seroprevalence for B. burgdorferi s.l. in the general population in The Netherlands was comparable to rates reported in European countries. The main risk factors for seropositivity were increasing age, being male and the tick bite frequency. The dynamics of LB infection are complex and involve variables from various disciplines. This could be further elucidated using infectious disease modelling.
7 October 2024 in European Journal of Clinical Microbiology & Infectious Diseases
Background Diagnosis of Lyme borreliosis (LB) relies on clinical symptoms and detection of Borrelia-specific antibodies. Guidelines recommend a two-tier testing (TTT) strategy for disseminated LB: serological screening with a sensitive enzyme immunoassay (EIA) and confirmation with a specific immunoblot. Searching for the most sensitive and specific approach, this retrospective study evaluated standard (STTT) and modified (MTTT) strategies using a well-defined study population. Methods Cases included patients with active Lyme neuroborreliosis (LNB; n = 29) or Lyme arthritis (LA; n = 17). Controls comprised patients treated for LNB (n = 36) or LA (n = 8), healthy individuals who were either untreated (n = 75) or treated for LB (n = 15) in the past, and patients with potentially cross-reactive diseases (n = 16). Sera were subjected to three EIAs and two immunoblots. Reactive screening results were confirmed by immunoblot (STTT) or EIA (MTTT). Solitary IgM results in the screening assay and effects of antibiotic treatment on isotype-specific seropositivity rates were also assessed. Results Sensitivities of STTT strategies ranged from 90%–97% for LNB and were 100% for LA. MTTT strategies were 100% sensitive. Specificities ranged from 89%–95% for STTT and from 88%–93% for MTTT strategies. Differences between STTT and MTTT strategies were not statistically significant. Solitary IgM reactivity was common among controls. Antibiotic treatment significantly reduced IgM/IgG positivity for LNB patients; for LA patients, a decline was only observed for IgM. Conclusion In conclusion, MTTT strategies showed a slightly higher sensitivity and similar specificity compared to STTT strategies. Since EIAs are more time- and cost-efficient, MTTT strategies seem more favorable for clinical use. IgG testing enhances specificity with minimal sensitivity loss.