Kélian Sommer

Mr. Kélian Sommer

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2025 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
KSKélian Sommer
Kélian Sommer
WKWassim Kabalan
Wassim Kabalan
RBRomain Brunet
Romain Brunet
Infrared thermal cameras offer reliable means of assessing atmospheric conditions by measuring the downward radiance from the sky, facilitating their usage in cloud monitoring endeavors. The precise identification and detection of clouds in images pose great challenges stemming from the indistinct boundaries inherent to cloud formations. Various methodologies for segmentation have been previously suggested. Most of them rely on color as the distinguishing criterion for cloud identification in the visible spectral domain and thus lack the ability to detect cloud structures in gray-scaled images with satisfying accuracy. In this work, we propose a new complete deep-learning framework to perform image classification and segmentation with convolutional neural networks. We demonstrate the effectiveness of this technique by conducting a series of tests and validations based on self-captured infrared sky images. Our findings reveal that the models can effectively differentiate between image types and accurately capture detailed cloud structure information at the pixel level, even when trained with a single binary ground-truth mask per input sample. The classifier model achieves an excellent accuracy of 99 % in image type distinction, while the segmentation model attains a mean pixel accuracy of 95 % in our dataset. We emphasize that our framework exhibits strong viability and can be used for infrared thermal ground-based cloud monitoring operations over extended durations. We expect to take advantage of this framework for astronomical applications by providing cloud cover selection criteria for ground-based photometric observations within the StarDICE experiment.

11 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
KSKélian Sommer
Kélian Sommer
BPBertrand Plez
Bertrand Plez
JCJohann Cohen-Tanugi
Johann Cohen-Tanugi
SDSylvie Dagoret-Campagne
Sylvie Dagoret-Campagne
MMMarc Moniez
Marc Moniez
TSThierry Souverin
Thierry Souverin
The StarDICE experiment strives to establish an instrumental metrology chain with a targeted accuracy of 1 mmag in griz bandpasses to meet the calibration requirements of next-generation cosmological surveys. Atmospheric transmission is a significant source of systematic uncertainty. We propose a solution relying on an uncooled infrared thermal camera to evaluate gray extinction variations. However, achieving accurate measurements with thermal imaging systems necessitates prior calibration due to temperature-induced effects, compromising their spatial and temporal precision. Moreover, these systems cannot provide scene radiance in physical units by default. This study introduces a new calibration process utilizing a tailored forward modeling approach. The method incorporates sensor, housing, flat-field support, and ambient temperatures, along with raw digital response, as input data. Experimental measurements were conducted inside a climatic chamber, with a FLIR Tau2 camera imaging a thermoregulated blackbody source. The results demonstrate the calibration effectiveness, achieving precise radiance measurements with a temporal pixel dispersion of 0.09 W m−2 sr−1 and residual spatial noise of 0.03 W m−2 sr−1. We emphasize that the accuracy of scene radiance retrieval can be systematically affected by the camera’s close thermal environment, especially when the ambient temperature exceeds that of the scene.

1 December 2001 in Optics Letters
Verified
Journal Article
Closed access
PDF file
JCJohn Canning
John Canning
KSKélian Sommer
Kélian Sommer
Deterioration of the gain coefficient as a result of UV processing of hydrogen-loaded Er3+- and Er3+/Yb3+-doped silicate optical waveguides can be reduced by initial hypersensitization of the waveguide prior to bulk irradiation. This allows improved performance in active-grating devices such as distributed-feedback fiber amplifiers and lasers.

5 January 2024 in RAS Techniques and Instruments
Verified
Journal Article
Open access
PDF file
KSKélian Sommer
Kélian Sommer
JCJohann Cohen-Tanugi
Johann Cohen-Tanugi
BPBertrand Plez
Bertrand Plez
MBM Betoule
M Betoule
SBS Bongard
S Bongard
CSChristopher Stubbs
Christopher Stubbs
Type Ia supernovae are the most direct cosmological probe to study dark energy in the recent Universe, for which the photometric calibration of astronomical instruments remains one major source of systematic uncertainties. To address this, recent advancements introduce collimated beam projectors (CBPs), aiming to enhance calibration by precisely measuring a telescope’s throughput as a function of wavelength. This work describes the performance of a prototype portable CBP. The experimental set-up consists of a broad-band Xenon light source replacing a more customary but much more demanding high-power laser source, coupled with a monochromator emitting light inside an integrating sphere monitored with a photodiode and a spectrograph. Light is injected at the focus of the CBP telescope projecting a collimated beam onto a solar cell whose quantum efficiency has been obtained by comparison with a NIST-calibrated photodiode. The throughput and signal-to-noise ratio achieved by comparing the photocurrent signal in the CBP photodiode with the one in the solar cell are computed. We prove that the prototype, in its current state of development, is capable of achieving 1.2 per cent and 2.3 per cent precision on the integrated g and r bands of the Zwicky Transient Facility photometric filter system, respectively, in a reasonable amount of integration time. Central wavelength determination accuracy is kept below ∼0.91 and ∼0.58 nm for g and r bands, respectively. The expected photometric uncertainty caused by filter throughput measurement is approximately 5 mmag on the zero-point magnitude. Several straightforward improvement paths are discussed to upgrade the current set-up.

3 January 2025 in RAS Techniques and Instruments
Verified
Journal Article
Open access
TSThierry Souverin
Thierry Souverin
JNJérémy Neveu
Jérémy Neveu
MBMarc Betoule
Marc Betoule
SBSébastien Bongard
Sébastien Bongard
CSChristopher W Stubbs
Christopher W Stubbs
KSKélian Sommer
Kélian Sommer
The measurement of Type Ia supernovae magnitudes provides cosmological distances, which constrain dark energy parameters. Current and upcoming large photometric surveys require improved photometric calibration precision to reduce systematic uncertainties in cosmological constraints. The StarDICE experiment aims to establish accurate broad-band flux references for these surveys, targeting sub-percent precision in magnitude measurements. Achieving this requires precise filter bandpass measurements for both StarDICE and survey instruments with sub-nanometre accuracy. To this end, we developed the Collimated Beam Projector (CBP), an optical device for calibrating the throughput of astronomical telescopes and their filters. The CBP uses a tunable laser source and a reversed telescope to emit a parallel monochromatic light beam, continuously monitored in flux and wavelength. The CBP output flux is measured with a large-area photodiode calibrated relative to a NIST photodiode. Using CBP measurements, we derive the StarDICE telescope throughput and filter transmissions, anchoring them to NIST’s absolute calibration. After analysing systematic uncertainties, we achieved sub-nanometre accuracy for filter central wavelengths, measured filter transmission with ~0.5 per cent precision per $1 \,{\rm nm}$ bin, and detected out-of-band leakages at a relative level of $10^{-4}$. Furthermore, we synthesized equivalent transmission for full pupil illumination from four sampled positions in the StarDICE telescope mirror, with ~$0.2 \,{\rm nm}$ accuracy for central wavelengths and $7 \,{\rm mmag}$ for broad-band fluxes. This demonstrates our ability to characterize telescope throughput down to the millimagnitude, paving the way for future developments, such as the Rubin-CBP for measuring the LSST at Vera Rubin Observatory, and a portable CBP version for in-situ transmission monitoring.

10 July 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
KSKélian Sommer
Kélian Sommer
BPBertrand Plez
Bertrand Plez
JCJohann Cohen-Tanugi
Johann Cohen-Tanugi
SDSylvie Dagoret-Campagne
Sylvie Dagoret-Campagne
MMMarc Moniez
Marc Moniez
TSThierry Souverin
Thierry Souverin
The StarDICE experiment strives to establish an instrumental metrology chain with a targeted accuracy of 1 mmag in griz bandpasses to meet the calibration requirements of next-generation cosmological surveys. Atmospheric transmission stands out as a significant source of systematic uncertainty. Specifically, gray extinction induces spurious variations of photometric fluxes. We propose a solution relying on an uncooled long-wave infrared thermal camera to evaluate it. This type of camera can provide real-time insights into atmospheric conditions and detect cirrus clouds. However, achieving accurate measurements with thermal imaging systems necessitates prior calibration due to the influence of temperature-induced effects, which compromise their spatial and temporal precision. Moreover, these systems cannot provide scene radiance values in physical units by default. This study introduces a new calibration process utilizing a tailored forward modeling approach. The method is applied to an uncooled FLIR Tau2 thermal camera. It incorporates sensor, housing, flat-field support, and ambient temperatures, along with raw digital response, as input data. Experimental measurements are conducted inside a climatic chamber, with the camera imaging a thermoregulated blackbody source. Results demonstrate the calibration effectiveness, achieving precise radiance measurements with a temporal pixel root-mean-square error (RMSE) of 0.09 W/m2/srand residual spatial noise of 0.03 W/m2/sr.