Kevin Niño-Tejada

Mr. Kevin Niño-Tejada

Electrical Engineering, University of Puerto Rico-Mayaguez, Mayagüez, USA
orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2025 in Data
Verified
Journal Article
Open access
PDF file
Jhonathan Leonardo Rivas CaicedoJhonathan Leonardo Rivas Caicedo
Jhonathan Leonardo Rivas Caicedo
LSLaura Saldaña-Aristizábal
Laura Saldaña-Aristizábal
Kevin Niño-TejadaKevin Niño-Tejada
Kevin Niño-Tejada
Juan PatarroyoJuan Patarroyo
Juan Patarroyo
Human Activity Recognition (HAR) using wearable sensors is an increasingly relevant area for applications in healthcare, rehabilitation, and human–computer interaction. However, publicly available datasets that provide multi-sensor, synchronized data combining inertial and orientation measurements are still limited. This work introduces a publicly available dataset for Human Activity Recognition, captured using wearable sensors placed on the chest, hands, and knees. Each device recorded inertial and orientation data during controlled activity sessions involving participants aged 20 to 70. A standardized acquisition protocol ensured consistent temporal alignment across all signals. The dataset was preprocessed and segmented using a sliding window approach. An initial baseline classification experiment, employing a Convolutional Neural Network (CNN) and Long-Short Term Memory (LSTM) model, demonstrated an average accuracy of 93.5% in classifying activities. The dataset is publicly available in CSV format and includes raw sensor signals, activity labels, and metadata. This dataset offers a valuable resource for evaluating machine learning models, studying distributed HAR approaches, and developing robust activity recognition pipelines utilizing wearable technologies.

30 July 2025 in Electronics
Verified
Journal Article
Open access
PDF file
Kevin Niño-TejadaKevin Niño-Tejada
Kevin Niño-Tejada
LSLaura Saldaña-Aristizábal
Laura Saldaña-Aristizábal
Jhonathan Leonardo Rivas CaicedoJhonathan Leonardo Rivas Caicedo
Jhonathan Leonardo Rivas Caicedo
Juan PatarroyoJuan Patarroyo
Juan Patarroyo
Accurate estimation of upper-limb joint angles is essential in biomechanics, rehabilitation, and wearable robotics. While inertial measurement units (IMUs) offer portability and flexibility, systems requiring multiple inertial sensors can be intrusive and complex to deploy. In contrast, optical motion capture (MoCap) systems provide precise tracking but are constrained to controlled laboratory environments. This study presents a deep learning-based approach for estimating shoulder and elbow joint angles using only three IMU sensors positioned on the chest and both wrists, validated against reference angles obtained from a MoCap system. The input data includes Euler angles, accelerometer, and gyroscope data, synchronized and segmented into sliding windows. Two recurrent neural network architectures, Convolutional Neural Network with Long-short Term Memory (CNN-LSTM) and Bidirectional LSTM (BLSTM), were trained and evaluated using identical conditions. The CNN component enabled the LSTM to extract spatial features that enhance sequential pattern learning, improving angle reconstruction. Both models achieved accurate estimation performance: CNN-LSTM yielded lower Mean Absolute Error (MAE) in smooth trajectories, while BLSTM provided smoother predictions but underestimated some peak movements, especially in the primary axes of rotation. These findings support the development of scalable, deep learning-based wearable systems and contribute to future applications in clinical assessment, sports performance analysis, and human motion research.

12 August 2025 in Electronics
Verified
Journal Article
Open access
PDF file
Jhonathan Leonardo Rivas CaicedoJhonathan Leonardo Rivas Caicedo
Jhonathan Leonardo Rivas Caicedo
Kevin Niño-TejadaKevin Niño-Tejada
Kevin Niño-Tejada
LSLaura Saldaña-Aristizábal
Laura Saldaña-Aristizábal
Juan PatarroyoJuan Patarroyo
Juan Patarroyo
Human Activity Recognition (HAR) using wearable sensors plays a critical role in applications such as healthcare, sports monitoring, and rehabilitation. Traditional approaches typically rely on centralized models that aggregate and process data from multiple sensors simultaneously. However, such architecture often suffers from high latency, increased communication overhead, limited scalability, and reduced robustness, particularly in dynamic environments where wearable systems operate under resource constraints. This paper proposes a distributed neural network framework for HAR, where each wearable sensor independently processes its data using a lightweight neural model and transmits high-level features or predictions to a central neural network for final classification. This strategy alleviates the computational load on the central node, reduces data transmission across the network, and enhances user privacy. We evaluated the proposed distributed framework using our publicly available multi-sensor HAR dataset and compared its performance against a centralized neural network trained on the same data. The results demonstrate that the distributed approach achieves comparable or superior classification accuracy while significantly lowering inference latency and energy consumption. These findings underscore the promise of distributed intelligence in wearable systems for real-time and energy-efficient human activity monitoring.

1 August 2025 in Electronics
Verified
Journal Article
Open access
PDF file
LSLaura Saldaña-Aristizábal
Laura Saldaña-Aristizábal
Jhonathan Leonardo Rivas CaicedoJhonathan Leonardo Rivas Caicedo
Jhonathan Leonardo Rivas Caicedo
Kevin Niño-TejadaKevin Niño-Tejada
Kevin Niño-Tejada
Juan PatarroyoJuan Patarroyo
Juan Patarroyo
Cardiorespiratory fitness is a predictor of long-term health, traditionally assessed through structured exercise protocols that require maximal effort and controlled laboratory conditions. These protocols, while clinically validated, are often inaccessible, physically demanding, and unsuitable for unsupervised monitoring. This study proposes a non-invasive, unsupervised alternative—predicting the heart rate a person would reach after completing the step test, using wearable data collected during natural daily activities. Ground truth post-exercise heart rate was obtained through the Queens College Step Test, which is a submaximal protocol widely used in fitness settings. Separately, wearable sensors recorded heart rate (HR), blood oxygen saturation, and motion data during a protocol of lifestyle tasks spanning a range of intensities. Two machine learning models were developed—a Human Activity Recognition (HAR) model that classified daily activities from inertial data with 96.93% accuracy, and a regression model that estimated post step test HR using motion features, physiological trends, and demographic context. The regression model achieved an average root mean squared error (RMSE) of 5.13 beats per minute (bpm) and a mean absolute error (MAE) of 4.37 bpm. These findings demonstrate the potential of test-free methods to estimate standardized test outcomes from daily activity data, offering an accessible pathway to infer cardiorespiratory fitness.

19 August 2026 in Electronics
Verified
Journal Article
Open access
PDF file
Jhonathan Leonardo Rivas CaicedoJhonathan Leonardo Rivas Caicedo
Jhonathan Leonardo Rivas Caicedo
LSLaura Saldaña-Aristizábal
Laura Saldaña-Aristizábal
Kevin Niño-TejadaKevin Niño-Tejada
Kevin Niño-Tejada
Juan PatarroyoJuan Patarroyo
Juan Patarroyo
Real-time multi-sensor human activity recognition (HAR) requires accurate models and a system architecture capable of distributing computation, exchanging compact outputs, and maintaining temporal consistency across asynchronous streams. This paper presents a distributed HAR framework in which five wearable sensors are associated with local embedded nodes that perform acquisition, windowing, preprocessing, and convolutional neural network–long short-term memory (CNN–LSTM) inference. Each node transmits a timestamped six-class softmax vector, and a central node applies approximate synchronization and learned probability-level fusion. The framework was evaluated with ten participants whose data were not used for model development. It achieved 95.868% accuracy and a 95.642% macro-F1-score. During continuous operation, the system sustained 47.949 predictions/s, with a mean post-window end-to-end latency of 33.963 ms and a mean synchronization span of 13.788 ms. Relative to complete-window transmission, the numerical payload decreased by 97.69%, and central-node energy per prediction decreased by 52.2% compared with centralized real-time processing. Under 30% independent probability-message loss, accuracy remained at 94.31%.

21 July 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Jhonathan Leonardo Rivas CaicedoJhonathan Leonardo Rivas Caicedo
Jhonathan Leonardo Rivas Caicedo
LSLaura Saldaña-Aristizábal
Laura Saldaña-Aristizábal
Kevin Niño-TejadaKevin Niño-Tejada
Kevin Niño-Tejada
Juan PatarroyoJuan Patarroyo
Juan Patarroyo
Real-time systems for Human Activity Recognition (HAR) with multiple wearable sensors require not only accurate classification models, but also an inference architecture capable of distributing computation, reducing communication payload, and maintaining temporal consistency across asynchronous sensor streams. This paper presents a real-time distributed HAR framework in which each wearable sensor is associated with a local embedded node responsible for data acquisition, window segmentation, preprocessing, and neural inference. Instead of transmitting raw inertial windows to a central processor, each local node transmits a timestamped softmax probability vector representing its local activity estimate. A central fusion node receives the local probability messages, applies approximate timestamp-based synchronization, and generates the final activity prediction through probability-level fusion. The framework was evaluated during real-time experiments involving six activities, five wearable inertial sensors, and distributed embedded nodes. The system achieved 95.86% global accuracy, a macro F1-score of 95.84%, a mean end-to-end latency of 33.96 ms, and a mean synchronization span of 13.787 ms, demonstrating feasible real-time distributed HAR under live communication and synchronization constraints.