Mota Xavier Kholopo

Mr. Mota Xavier Kholopo


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Mota Xavier KholopoMota Xavier Kholopo
Mota Xavier Kholopo
PRPhoka Caiphus Rathebe
Phoka Caiphus Rathebe
Radon is a naturally occurring noble radioactive gas that poses significant health risks, particularly lung cancer, due to its colorless, odorless, and tasteless nature, which makes detection challenging without formal testing. It is found in soil, rock, and water, and it infiltrates indoor environments, necessitating regulatory standards and guidelines from organizations such as the Environmental Protection Agency, the World Health Organization, and the Occupational Health and Safety Agency to mitigate exposure. In this paper, we present various methods and instruments for radon assessment in occupational and environmental settings. Discussion on long- and short-term monitoring, including grab sampling, radon dosimetry, and continuous real-time monitoring, is provided. The comparative analysis of detection techniques—active versus passive—is highlighted from real-time data and long-term exposure assessment, including advances in sensor technology, data processing, and public awareness, to improve radon exposure evaluation techniques.

7 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
PRPhoka Caiphus Rathebe
Phoka Caiphus Rathebe
Mota Xavier KholopoMota Xavier Kholopo
Mota Xavier Kholopo
This study presents a comprehensive evaluation and selection framework for extremely low-frequency electromagnetic field (ELF-EMF) measurement instruments. Recognizing the diversity of application environments and technical constraints, the framework addresses the challenges of selecting appropriate tools for specific scenarios. It integrates a structured, quantitative approach through a weighted scoring matrix that evaluates instrumentation across six criteria: monitoring duration, sensitivity, environmental adaptability, biological/regulatory relevance, usability, and cost. Complementing this is a logic-based flowchart that visually guides decision-making based on user-defined operational needs. The framework is applied to a realistic occupational case study, demonstrating its effectiveness in producing evidence-based, scenario-sensitive instrument recommendations. This method provides stakeholders with a transparent and adaptable tool for ELF-EMF device selection.

30 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
PRPhoka Caiphus Rathebe
Phoka Caiphus Rathebe
Mota Xavier KholopoMota Xavier Kholopo
Mota Xavier Kholopo
This review aimed to explore advances in radon detection methods, emphasizing cost-effectiveness and accessible techniques such as CDs, DVDs, and glass-based detectors. In this review, we compared traditional methods like alpha track detectors and continuous radon monitors with emerging innovations that leverage polycarbonate material and IoT-integrated systems. Our evaluation of the synthesis suggests that CDs and DVDs provide scalable solutions for long-term radon monitoring, while glass-based detectors like CR-39 offer high sensitivity for epidemiological studies. The integration of IoT and AI technologies further enhances real-time radon monitoring, paving the way for precise, scalable, and affordable radon mitigation strategies. This work highlights the importance of low-cost, innovative approaches in reducing radon-related lung cancer risks and informs future research on optimizing the technologies for diverse environments.

5 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
PRPhoka Caiphus Rathebe
Phoka Caiphus Rathebe
Mota Xavier KholopoMota Xavier Kholopo
Mota Xavier Kholopo
Radon exposure is the second leading cause of lung cancer worldwide, yet monitoring strategies remain limited, expensive, and unevenly applied. Recent advances in the Internet of Things (IoT) offer the potential to change radon surveillance through low-cost, real-time, distributed sensing networks. This review consolidates emerging research on IoT-based radon monitoring, drawing from both primary radon studies and analogous applications in environmental IoT. A search across six major databases and relevant grey literature yielded only five radon-specific IoT studies, underscoring how new this research field is rather than reflecting a shortcoming of the review. To enhance the analysis, we delve into sensor physics, embedded system design, wireless protocols, and calibration techniques, incorporating lessons from established IoT sectors like indoor air quality, industrial safety, and volcanic gas monitoring. This interdisciplinary approach reveals that many technical and logistical challenges, such as calibration drift, power autonomy, connectivity, and scalability, have been addressed in related fields and can be adapted for radon monitoring. By uniting pioneering efforts within the broader context of IoT-enabled environmental sensing, this review provides a reference point and a future roadmap. It outlines key research priorities, including large-scale validation, standardized calibration methods, AI-driven analytics integration, and equitable deployment strategies. Although radon-focused IoT research is still at an early stage, current progress suggests it could make continuous exposure assessment more reliable, affordable, and widely accessible with clear public health benefits.

13 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
PRPhoka Caiphus Rathebe
Phoka Caiphus Rathebe
Mota Xavier KholopoMota Xavier Kholopo
Mota Xavier Kholopo
The deployment of 5G networks has transformed the landscape of radiofrequency electromagnetic field (RF-EMF) exposure patterns, shifting from high-power macro base stations to dense networks of small, beamforming cells. This review critically assesses the validity, challenges, and research gaps of low-cost RF-EMF sensors used for 5G exposure monitoring. An analysis of over 60 studies covering Sub-6 GHz and emerging mmWave systems shows that well-calibrated sensors can achieve measurement deviations of ±3–6 dB compared to professional instruments like the Narda SRM-3006, with long-term calibration drift less than 0.5 dB per month and RMS reproducibility around 5%. Typical outdoor 5G FR1 exposure levels range from 0.01 to 0.5 W/m2 near small cells, while personal device use can cause transient exposures 10–30 dB higher. Although mmWave (24–100 GHz) and Wi-Fi 7/8 (~60 GHz) are underrepresented due to antenna and component limitations, Sub-6 GHz sensing platforms, including software-defined radio (SDR)-based and triaxial isotropic designs, provide sufficient sensitivity for both citizen and institutional monitoring. Major challenges involve calibration drift, frequency band gaps, data interoperability, and ethical management of participatory networks. Addressing these issues through standardized calibration protocols, machine learning-assisted drift correction, and open data frameworks will allow affordable sensors to complement professional monitoring, improve spatial coverage, and enhance public transparency in 5G RF-EMF exposure governance.

15 September 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PRPhoka Caiphus Rathebe
Phoka Caiphus Rathebe
Mota Xavier KholopoMota Xavier Kholopo
Mota Xavier Kholopo
Radon (222Rn) is a naturally occurring radioactive noble gas and a leading cause of lung cancer after tobacco smoking. Elevated concentrations in groundwater, mainly from uranium-rich geological formations, pose significant health risks in regions reliant on groundwater. This review critically examines current tools and techniques for detecting radon in drinking water, focusing on how methodological choices affect reported levels and risk assessments. A structured literature review from major scientific databases covers established laboratory methods like liquid scintillation counting (LSC), alpha/gamma spectrometry, Lucas cells, and electret chambers, alongside field methods such as the RAD7, and new technologies including IoT sensors and AI analytics. The review finds that accurate radon measurement is limited more by sampling losses due to volatility, radioactive decay (half-life: 3.82 days), and the heterogeneity of fractured aquifers, than by instrument precision. While LSC remains the regulation standard for its traceability and low detection limits, portable methods are key for quick field screening, and automated systems are increasingly important for capturing transient changes in treatment settings and high-risk aquifers. A decision matrix is provided to help choose methods based on monitoring goals, infrastructure, and needed confidence levels. The study emphasizes that improving data quality and comparability requires not just technological progress but also harmonized sampling protocols, rigorous quality assurance, transparent uncertainty reporting, and the inclusion of hydrogeological context in monitoring design. This comprehensive approach is crucial for translating measurements into effective exposure assessments, regulatory decisions, and public health protections.