Jung Ho Kim

Dr. Jung Ho Kim

Electronic Warfare R&D Center, LIG Nex1, Seongnam-si, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2015 in Journal of Infrared, Millimeter, and Terahertz Waves
Verified
Journal Article
Closed access
PDF file
SKSung Gug Kim
Sung Gug Kim
ASAshwini Sawant
Ashwini Sawant
ILIngeun Lee
Ingeun Lee
DKDongsung Kim
Dongsung Kim
MCMunSeok Choe
MunSeok Choe
ECEunMi Choi
EunMi Choi

9 November 2009 in Physical Review Special Topics - Accelerators and Beams
Verified
Journal Article
Open access
PDF file
JHJaeeun Han
Jaeeun Han
JKJung Ho Kim
Jung Ho Kim
SPSang-Duck Park
Sang-Duck Park
MYMoohyun Yoon
Moohyun Yoon
SPSoo Yong Park
Soo Yong Park
JSJoon Ho So
Joon Ho So
A coaxial-type water load was used to measure the voltage output from a Marx generator for a high power microwave source. This output had a rise time of 20 ns, a pulse duration of a few hundred ns, and an amplitude up to 500 kV. The design of the coaxial water load showed that it is an ideal resistive divider and can also accurately measure a short pulse. Experiments were performed to test the performance of the Marx generator with the calibrated coaxial water load.

19 August 2015 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
SKSung Gug Kim
Sung Gug Kim
JKJung Ho Kim
Jung Ho Kim
DKDongsung Kim
Dongsung Kim
JWJong-Hyo Won
Jong-Hyo Won
WLWoo Sang Lee
Woo Sang Lee
ECEunMi Choi
EunMi Choi
Measurements of the absolute power of high-power millimeter/THz wave generators have been considered to be highly variable and to occasionally produce faulty results owing to experimental difficulty. In this study, we propose a calibration-free method for real-time power measurement of an electron cyclotron maser system, a so-called gyrotron. We demonstrate the feasibility of the method by using a recently developed W-band gyrotron with a peak power of tens of kilowatts. The technique is based on transmitter antenna power measurement by using the Friis transmission equation with a defined gyrotron antenna gain. The new technique will allow extremely simple and accurate real-time measurement of output power over a wide dynamic range ( dB) for continuous wave sources to high-power millimeter/THz wave sources with nanosecond pulse lengths.

15 July 2010 in Physical Review Special Topics - Accelerators and Beams
Verified
Journal Article
Open access
PDF file
JKJung Ho Kim
Jung Ho Kim
JHJ. Han
J. Han
MYM. Yoon
M. Yoon
SPS. Y. Park
S. Y. Park
An analytical solution of a wakefield from a charge moving on the axis of a dielectric-filled cylindrical cavity is derived. A solution to the wakefield in a waveguide with only a boundary at the cavity entrance is already known. To take into account a boundary at the cavity exit, we introduce an imaginary antibeam, with opposite charge, which is created at the same time when the beam passes the exit boundary and continues to move along with the original beam at the same velocity. Although the beam has been annihilated in the net effect, the original beam and the antibeam produce their own wakefields, respectively, because they were created at different times. These superimposed fields are then mirror reflected as usual by the conducting exit boundary and the wakefield can be obtained by properly mirror reflecting them whenever it reaches a boundary. We find a resonance condition to enhance wakefields with multiple bunches of charges, and show that the acceleration gradient increases under that condition.

31 March 2012 in The Journal of Korean Institute of Electromagnetic Engineering and Science
Verified
Journal Article
Open access
HKHee-Do Kang
Hee-Do Kang
IOIl-Young Oh
Il-Young Oh
JKJung Ho Kim
Jung Ho Kim
JYJong-Gwan Yook
Jong-Gwan Yook

22 March 2016 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
SKS. C. Kim
S. C. Kim
HHH. Heo
H. Heo
CMC. Moon
C. Moon
SNS. H. Nam
S. H. Nam
DKD. S. Kim
D. S. Kim
JSJ. H. Sho
J. H. Sho
This paper proposes a compact high-voltage pulse electron gun power supply (EGPS) consisted of interleaved capacitor-charging power supply (CCPS) with a series-resonant converter (SRC) to drive the electron tube. Requirement specifications are -40 kV, -7 A (280 kW), and continuous output lower than ±1% ripple stability lasted few seconds with <;1 ms charging and discharging times. To meet the design specifications, eight stacks operate in parallel, and each stack has a 45° phase shift switching pulse width modulation (PWM) method. Each designed CCPS can supply -40-kV voltage and -0.9-A current. In addition, the proposed CCPS has the SRC to reduce the switching loss. The SRC is a famous topology, which presents main characteristics such as high-power density and efficiency. To prove the validity, this paper is confirmed by the simulation and experimental results of the fabricated -40-kV output CCPS with water load. Then, we implemented the fabricated EGPS to the electron tube.